Recent content by leezard

  1. L

    raypak 266 no pilot detected

    So it turns out the idiot (that would be me) that installed the new control board after the gecko blew the old one up didn't have a good seating of the pilot light send/receive wire. All good now. thanks. thanks for the info.
  2. L

    raypak 266 no pilot detected

    they are all clean, especially now since i went out and scrubbed them all, and checked with an ohm meter. 1ohm or less. same problem across several attempts.
  3. L

    raypak 266 no pilot detected

    I have a raypak 266 natural gas spa heater. I recently had a gecko get behind the control board and cooked it (2nd time this year). At any rate, i replaced the control board (again) and tried to light the heater and during the startup process it stayed in the spark process and never detected...