Recent content by Kevo5oh

  1. K

    After backwash motor won't come on?!

    Got it fixed! It was the breaker! Like yall said..once I tested the L1 & L2 together and got 0 and tested another double pole in the box that gave me 240 I knew it was for sure bad then. Replaced and back in business! Thanks again guys for all the help!
  2. K

    After backwash motor won't come on?!

    Seems I remember testing both leads at the same time..one lead on L1 the other on L2 at the same time and got 0...I think. I did turn breaker on/off but not while testing...nothing. It's a double 20a breaker.
  3. K

    After backwash motor won't come on?!

    Guys thanks so much! So I need to disconnect the leads from the motor and put my multi meter probes one on each wire? And I should see 220v ish if the breaker is good..right? Prob 120v if bad?
  4. K

    After backwash motor won't come on?!

    Here's some pics. Anytime I've heard or seen a capacitor fail the motor seems to always "hum" like it's trying to start but just can't. Is this not always the case?
  5. 20190726_161007.jpg

    20190726_161007.jpg

  6. 20190726_160736.jpg

    20190726_160736.jpg

  7. 20190726_160730.jpg

    20190726_160730.jpg

  8. 20190726_160750.jpg

    20190726_160750.jpg

  9. 20190726_162026.jpg

    20190726_162026.jpg

  10. 20190726_162017.jpg

    20190726_162017.jpg

  11. K

    After backwash motor won't come on?!

    backwashed..now motor won't power back on. A friend says prob the start/run capacitor..but doesn't the motor at least "hum" when it's a bad capacitor? It's dead silent..no sound at all. I put a multi meter on it. Has power to the breaker and the leads going into the pump. 124v on each side...
  12. K

    Who uses a portable pump for spring clean ups? Tell me about your set up. I use a 3/4hp/1.0sf Hayward super pump. I feel like i need more power!

    Maybe a different vacuum head? I know when the brushes get worn and flat on mine it will suck better. If I'm doing a fiberglass or gunite/concrete Pool the vac head for that is much lower to the surface and has wheels..so of course suction is greatly increased. But that heads not safe for vinyl...
  13. K

    Who uses a portable pump for spring clean ups? Tell me about your set up. I use a 3/4hp/1.0sf Hayward super pump. I feel like i need more power!

    aj, is he satisfied with its power? Just seems like my old 3/4 hp super pump back in the day would suck up big piles of leaves very quickly...this new one will do it ..eventually..kinda have to sometimes "camp out" for a bit.
  14. K

    Who uses a portable pump for spring clean ups? Tell me about your set up. I use a 3/4hp/1.0sf Hayward super pump. I feel like i need more power!

    Hey James, Yes pump is set to 115 when I wired it. I will crack it open and check the impeller. Haven't in awhile...I do sometimes do vac out on concrete/rocks after work has been completed. Basket I keep clean..not cracked. Full prime..no air bubbles...runs good. Maybe I'll just try a...