Recent content by jkessack

  1. J

    Air Bubble in Pump

    Thanks, I will check this out. I started thinking that it might be the ball valves as well. I turned the pump off, then turned both valves off. Then I opened the pump and filled the chamber with water, in about 5 minutes the water went down a couple of inches. I think I will pursue replacing...
  2. J

    Air Bubble in Pump

    With main on and vacuum off I get air, not a lot but some. When I have both the vacuum and main line on I get no air. I had not tried it with vacuum only until I saw this note. I get a lot of air when I run with the vacuum line only, but I am not sure if this is because the vacuum opening is...
  3. J

    Air Bubble in Pump

    The main line and the vacuum line are separate lines from the pool. They join together just before the pump. Each line has a on/off ball valve prior to joining together. I guess that means that my vacuum is suction. Water level should not be an issue.
  4. J

    Air Bubble in Pump

    Thanks. I have a 10,000 Gallon Kidney shaped pool. The pump, filter, and heater are 25 feet away from the pool connected with underground 2 inch PVC pipe. One pipe goes from the skimmer to just before the pump another pipe runs from a vacuum attachment to just before the pump. Both pipes have...
  5. J

    Air Bubble in Pump

    Hi, I am new to the forum. I have a new problem with my pool system. I am getting some air bubbles in the pump this year, some of these are making through the filter and heater back to the pool jets. The air bubbles disappear when I turn on the pool vacuum. So if I leave the creepy crawley...