Recent content by jfarthing84

  1. J

    IC40 Wire Fire

    Turns out, nothing. They won't do anything. At the very least, I thought they may want to determine what would cause their product to nearly burn a customer's house down. Apparently not.
  2. J

    IC40 Wire Fire

    It seems we should be considering what caused the heat/fire/melting to begin with. If I reconnect the IC40, won't it possibly happen again? Or are you saying that the "surge card" may have been the problem?
  3. J

    IC40 Wire Fire

    This worked - thanks! At least now I can manually chlorinate and still circulate while awaiting Pentair or my own replacements.
  4. J

    IC40 Wire Fire

    The pump data cable connects to the bottom of the SCG circuit board in my last picture.
  5. J

    IC40 Wire Fire

    My guess would be one of the other two connections to the SCG circuit board, but I can go trace it if needed.
  6. J

    IC40 Wire Fire

    Sure thing - the last one is a closeup of the PCB that the IC40 connects to.
  7. IMG_0813.jpeg

    IMG_0813.jpeg

  8. IMG_0814.jpeg

    IMG_0814.jpeg

  9. IMG_0816.jpeg

    IMG_0816.jpeg

  10. J

    IC40 Wire Fire

    Came out to do some maintenance today and noticed my EasyTouch panel covered in black soot. Upon closer inspection, it seems the wiring from the panel to the IC40 had caught fire/melted. I was able to find one other thread on this forum where the same thing occurred. In talks with Pentair...
  11. IMG_0806.jpeg

    IMG_0806.jpeg

  12. IMG_0807.jpeg

    IMG_0807.jpeg

  13. IMG_0808.jpeg

    IMG_0808.jpeg

  14. IMG_0809.jpeg

    IMG_0809.jpeg

  15. IMG_0810.jpeg

    IMG_0810.jpeg