  1. J

    Pentair Ultratemp 140 Compressor Issue?

    All of the advice is very much appreciated! I'll be sure to keep an eye on the replacement process. Pentair covers parts and labor, but I will have to see about all of the extra, like you have mentioned. Thank you!
  2. J

    Pentair Ultratemp 140 Compressor Issue?

    I really do appreciate the help. I actually thought it was out of warranty, but you're correct in that Pentair has a 10 year warranty on the compressor itself!
  3. J

    Pentair Ultratemp 140 Compressor Issue?

    I don't think the compressor made any noise, although the fan might be drowning it out. Otherwise I think it's just the fan blowing the whole time while it's warming up, and the compressor didn't start at all. I measured less than 1 ohm of resistance between L1 and L2. And about 1 ohm between L1...
  4. J

    Pentair Ultratemp 140 Compressor Issue?

    I'm getting 27V between TBL1 and TBL2, TBL1 and TBR1, TBL1 and TBR3. However I'm getting zero voltage between TBL1 and all of the TBLs up to #8. I am getting 27V between TBL2 and all of the TBLs up to #8. Also, the black contact cutout DID pull in when the warming up timer finished and the...
  5. J

    Pentair Ultratemp 140 Compressor Issue?

    Here are some photos. Let me know if there are more that I need to take.
  6. 1000014706.jpg

    1000014706.jpg

  7. 1000014703.jpg

    1000014703.jpg

  8. 1000014700.jpg

    1000014700.jpg

  9. J

    Pentair Ultratemp 140 Compressor Issue?

    I'm getting 244 V between T1 and T2. I'm getting zero volts between L1 and L2. Where am I supposed to put the multimeter to read 24V? And I really appreciate the help, by the way! 🙏
  10. 1000014679.jpg

    1000014679.jpg

  11. 1000014678.jpg

    1000014678.jpg

  12. J

    Pentair Ultratemp 140 Compressor Issue?

    I'm getting zero volts across either the top two or bottom two. Here's a link to the video of the compressor. 10 seconds in you'll hear the click. Compressor video
  13. 1000014680.jpg

    1000014680.jpg

  14. J

    Pentair Ultratemp 140 Compressor Issue?

    Hi, all. I have a Pentair ultratemp 140 pump, installed in 2018. I didn't use it at all last year as I never opened my pool last summer, but after I opened the pool this year I noticed it was not heating the water. Fan runs but water exiting is cold and the air blowing out of unit is air...
  15. J

    New Pool Owner: advice on VS Pump and Heat Pump

    Hi All, I'm glad I stumbled across this forum. Thanks in advance for whatever answers you might. I just spent hours on the phone talking to different pool companies and would like some of your thoughts, if you don't mind. I just moved into a new house in Long Island, NY, a few months ago with...