Recent content by JB426

  1. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    Just an update. I received and installed the Pentair 3/4 HP 340037 pump Friday. Everything went fairly smooth except for a bit of a fitment issue, had to raise the gas line a little that goes to the heater. I knew it would be a little tight but got it done and it's working great. All my low flow...
  2. download_20140623_083353.jpg

    download_20140623_083353.jpg

  3. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    Yeah I saw that and thanks for posting the info. I just got it from Amazon since I have free 2-day shipping with them so I'll get it by Friday for $8 more.
  4. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    Thanks Jason, sarg, vwerz. I don't have any other water features or a spa so that's what I thought. I think I'll just get the 340037 and save even a few more bucks. Amazon has it for 278 with Prime shipping.
  5. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    My current pump, a 1 HP Anthony AR205L, is probably 20-30 years old and not working very good. It's loud and the motor was replaced last year, which in retrospect was probably a mistake. It's just not pumping water like it did a couple of years ago. I've checked the impeller and it's not clogged...
  6. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    I'm in New Mexico and we only have the pool open for a max of about 4 months per year. So it would take a little longer to recoup the cost but I hear you. I found the Jandy FloPro FHPM 1.0-2SPD for $348 which seems like a great price but I don't think it comes with a switch for the 2 speeds on...
  7. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    I would go with a two speed but I'm trying to save some money now and I can't find a two speed for close to $300, which is what I can get the EE Superflo. I know in the long run it would make sense. My electricity rates are .12 per kwh, so I'm not sure how that compares. The pump on there now is...
  8. J

    Pentair Superflo Standard Efficiency vs. Energy Efficient and Install Question

    I think I'm going to replace my 1 HP Anthony pump with one of the following 3/4 HP pumps in bold below. Is the difference pretty straightforward, just that one is more energy efficient? I see that the SFHP for the energy efficient 3/4 HP pump is 1.25 which is the same as the standard efficiency...
  9. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    The impeller was not clogged. I've now noticed there is DE in the pool from when I manually cleaned and added new DE. There does not seem to be enough pressure in the filter, it's right at 2.5. I guess a lot of the DE did not stick to the grids and went into the pool. Should I just replace the...
  10. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    Thinking ahead, if I have to replace the pump should I go with a 3/4 HP or stick with a 1 HP? I was thinking if it comes down to this I would go with the Pentair Superflo. I know it would be beneficial to go with a 2 speed pump but I really don't want to spend the extra money and we only have...
  11. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    OK I will check that. This is how the situation was before I replaced the pump motor and I remember reading the impeller could be clogged. It wasn't then but maybe it is now. We do have a bunch of pine trees around and pine needles are a pain so maybe they worked into the impeller like you...
  12. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    OK just replaced the gauge. I'm getting about 2.5-3 PSI after bleeding out the air. Stays the same with main and skimmer open or just one or the other. The skimmer also flows very well by itself but pretty low when main is open. I would think if the grids were plugged a little it would show...
  13. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    Yeah, and I just replaced it but get no pressure reading at all. It was like $5 so I figured it was just defective. I know there has to be some pressure in there. When I bleed off the air the water will start squirting out just like it did back when everything was working normally. I'll see if I...
  14. J

    DE Filter Grids, Air bubbles in return, low suction from skimmer questions

    Here's my pool info: Small in-ground gunite pool about 7,850 gallons Pump is Anthony AR205-L Pump motor is 1 HP, 1.25 Service Factor, Amps 12.6/6.3 Anthony Apollo DE filter VA-52-2 52 sq. ft. Anthony pool heater Zodiac Caretaker unit OK guys, here's the deal. I'm getting very low skimmer...
  15. J

    Pump motor replacement for Anthony pump?

    Yes it's on its way with the motor. Should be a quick job now that the existing motor will come right off. Thanks.