Recent content by jasontucker

  1. J

    Aqualogic Losing Time?

    I tried replacing the surface mount parts shown here - but alas - I don't really have that soldering skill. I just decided to go ahead and replace my board. Can someone post a picture of the board installed? I'm pretty sure I know where all the cables re-connect - but there are a couple that...
  2. J

    High Salt / Amps - SWG turning off

    Got into config menu - cell is set properly to T-15. Not sure how to check the input line voltage...? Could you elaborate...? I've seen some posts about replacing the K1 relay. Could that be a problem? Is that easy to do...? Thanks very much for your responses. I appreciate the help.
  3. J

    High Salt / Amps - SWG turning off

    Diagnostic shows 40.62V 10.04A before it turns itself off and says High Salt/Amps. The current salt reading is only 1800. I don't have an exact salt reading, but it was working fine and reading fine the last time I had water tested. I've not added any salt since then and salt levels have...
  4. J

    High Salt / Amps - SWG turning off

    I could use some help here... A while back I had this Hight Salt/Amps message and found a solution on this forum - a little glob of solder on the back of the board and problem was solved. Fast forward a few years - T-15 cell was replaced with generic replacement from Compupool and worked fine...
  5. J

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Re: Aqua Logic Salt Too High - Cholrinator Off High Salt/Amp I could use some help here... I, too had this K1 solder problem a while back and found the solution on this forum. A little glob of solder on the back of the board and problem was solved. Fast forward a few years - T-15 cell was...
  6. J

    Goldline Aqua Logic not turning on pumps/lights/heater

    She's breathing again. Called a Hayward/Goldline warranty service company. Some pro-rated warranty on the board. There was an integrated circuit chip on the board that was burned up and a small part of the board actually melted. Not sure if it looked like that before - I think I might have...
  7. J

    Goldline Aqua Logic not turning on pumps/lights/heater

    Update - still no resolution. I called my pool guy and he came out today. He was able to determine that 220 power is present at the switch and inside the Aqua Logic box at the relays. As such, his theory is that the problem is with the board or the transformer. He wasn't sure how to test...
  8. J

    Goldline Aqua Logic not turning on pumps/lights/heater

    We've had quite a bit of rain. Don't recall any thunder/lightning recently. I don't really have anything to circulate the water. Tested the CL this morning. Of course, it was essentially zero. Added some Power Powder from Leslie's today - just to have something in it.
  9. J

    Goldline Aqua Logic not turning on pumps/lights/heater

    Could really use some help. Water is turning green as I type. I'm stumped. The controller appears to working perfectly - but none of the equipment (pumps, lights, blower, heater) will come on. Strangely, an exterior flood light near the equipment, which also appears to get power from the...
  10. J

    Goldline Aqua Logic not turning on pumps/lights/heater

    New to the forum - hoping someone has a suggestion. Aqua Logic PS-8 model has power. Lights up as if it's working, but isn't turning anything on. (e.g. pressing the filter button - the button lights up, the filter doesn't come on. pressing pool light or spa light - the button lights up as if...