Recent content by Harris4521

  1. H

    Solar sensor open

    Well I finally got it fixed. I bought a multimeter and checked the new water sensor that I had previously installed and it checked out good. The solar sensor on the roof tested bad. I replaced it and everything thing is working now. Thanks everyone I really appreciate it.
  2. H

    Solar sensor open

    I swapped them and nothing so I put them back and now the solar sensor is showing open instead of the water sensor. Are they the same sensor. If I replace the solar sensor the wires are a braided wire but everything thing I have been seeing is that the air,water and solar take the same sensor.
  3. H

    Heater issues! Please help

    My hot tub used to get an FLO error and like yours was OK part of the time. I went to the dealer I bought the spa from. They sold me the sensor and told me how to replace it. Really nothing to it. If you can get your hands on a manual you could probably replace it yourself. Now I have a pool and...
  4. H

    Solar sensor open

    The solar sensor is only 22 ga. Wire. All of the other sites are a heavier ga.
  5. H

    Solar sensor open

    Thank you. Where is the water sensor usually located
  6. H

    Solar sensor open

    I have checked the connections but I’ll check them again. I’ll see if I can swap the water and solar if that doesn’t work. Thanks for your help.
  7. H

    Solar sensor open

    I have a Pentair Solartouch and I’m getting a Solar water sensor open error. I have replaced the sensor but I’m still getting the same error.
  8. H

    Solar sensor open

    I have replaced my solar water sensor but it still reads open and the red light is still on.