Recent content by grove-buffer-borax

  1. G

    Pentair Intelliflo VSF Breaker Tripping Upon Turning On

    Update 1: I pulled the drive off, looked at the circuit board for burning, and it looked fine. I noticed that the ground screw was a touch loose when I took it apart. When I reassembled it, I tightened everything well. I flipped the breaker and turned on the pump and it fired right up. I don't...
  2. G

    Pentair Intelliflo VSF Breaker Tripping Upon Turning On

    Hi there! Thanks for taking the time to offer guidance. Please see my answers above and pictures attached and note that the Intelliflo VSF pump is attached to the top breaker. Thanks again!
  3. Drive Wiring.jpg

    Drive Wiring.jpg

  4. Drive Screen Prior to Tripping.jpg

    Drive Screen Prior to Tripping.jpg

  5. Inellicenter 2.jpg

    Inellicenter 2.jpg

  6. Drive Screen after Tripping.jpeg

    Drive Screen after Tripping.jpeg

  7. Intellicenter 1.jpg

    Intellicenter 1.jpg

  8. G

    Pentair Intelliflo VSF Breaker Tripping Upon Turning On

    I have a Pentair Intelliflo VSF 3HP pump that trips my GFCI breaker upon turning on. It's controlled by Pentair's Intellicenter. I had an Eaton GFCI and upgraded to a Siemens per suggestions on this forum but the breaker continues to trip. I'm getting around 230-240(I can't remember the exact...