    Stain Problem

    Hi All, I have a plaster pool and have several stains primarily in the deep end and closer to edge of pool. The stains are about 1 to 2 inches in diameter and they are yellow green colour. They are also rough when you touch them and they feel like they are attached to the pool surface. I have...
  2. G

    White stains in pool

    I made a silly mistake of not reading the instructions and added 5 Kg of a product called Refresh which is borate. What a did not realise was this product increased PH. After 2 hours checked pool and had white blochy stains where I had pured this stuff. I tried brushing which did nothing. I...
  3. G

    IS my PH too high

    I have 65000 litre concrete plaster pool with a SWG unit and I have the following numbers as per my Taylors kit. CL=1.60 PH=7.7 TA=100 CH=130 CYA=0 Water temp 16 celsius My Lsi index is -.42 as this is not too bad as water will warm up shortly. Is my PH high and should I be trying to get PH to...
  4. G

    Remove CC

    Sorry my mistake CYA is only about 40 to 50. I have an automatic SWG unit for PH and chlorine so I try and keep CYA at no more then 50.
  5. G

    Remove CC

    I have been testing chlorine during evening and morning fo a few days and there is about .2 to .3 usage also noted CC is about .2. How can I get rid of the CC. Figures are FC 4.2 CC 0.2 PH 7.4 TA 50 CH 550 CYA 500-550 Pool size 5000 ltrs(13200 gal)
  6. G

    Taylors kit reads low TA

    Thanks for info will investigate further. I don't think sensafe meter is wrong because sensafe was 60ppm and Taylors was 50pppm. I was a bit alarmed that TA was a bit low s I dumped about 2Kg(4.4 lb) and took another reading sometime later. Sensafe was 80ppm and Taylors still 50ppm. My pool is...
  7. G

    Taylors kit reads low TA

    I have a Taylors FAS DPD test kit. I drop five drops of final solution and colour changes from green to red and stays like that.
  8. G

    Taylors kit reads low TA

    I have a Taylors kit which is about 9 months old and lately the TS reading is consistent at 50ppm. To increase TA I dropped Bicarb Soda and tested with sensafe meter which read about 80ppm but Taylors kit still stated 50ppm. Also had water tested at pool shop which cofirmed the sensafe...