Recent content by fc01

  1. F

    Jandy Salt Production 00%

    Figured it out. will a new water temp sensor fix this aquapure SWG scenario?
  2. F

    will a new water temp sensor fix this aquapure SWG scenario?

    The fix was as simple as swapping the water temp sensor. In summary: Pool chlorine tested low despite ~1yr old Jandy SWG cell and salinity flow sensor. The Aqualink display panel showed "chlorine production 00%" and no error codes. The only lights were green in color, under "power on" "flow"...
  3. 1634877481256.png

    1634877481256.png

  4. 1634877494738.png

    1634877494738.png

  5. F

    Jandy Salt Production 00%

    @ZodieLavine I have the same no-PDA-water-temp along with 00% chlorine production in Auto mode (but controllable SWG production in Service mode. How did you resolve this? Thanks.
  6. F

    will a new water temp sensor fix this aquapure SWG scenario?

    What do you think about turning off the GFI every breaker on the panel and letting the entire box rest overnight, rather than letting the boost complete it's 24hr cycle? I did change the percent to 50 (from 80) on the PDA already. In a google search I came across this procedure. Should I do...
  7. F

    will a new water temp sensor fix this aquapure SWG scenario?

    For my power cycle attempt I turned off the breakers for filter/pump/heater/blower and system/power, but didn't touch GFI or lights. Nothing changed/improved. Then I triggered boost via PDA and see this: Jb and "cell on". Hope this adds some diagnostic value! Thanks.
  8. 1634327766548.png

    1634327766548.png

  9. 1634327711758.png

    1634327711758.png

  10. 1634327680153.png

    1634327680153.png

  11. F

    will a new water temp sensor fix this aquapure SWG scenario?

    Yes, the pump is on in those pictures. On the PDA the "set AquaPure" has been and still is 80%. When I use the B button on the panel it stays at 0. I recall when everything was normal I could only change the percent via the PDA not the panel. Is the 0% production because the "cell on" light is...
  12. F

    will a new water temp sensor fix this aquapure SWG scenario?

    @PoolGate @zac280 does my situation seem like the same problem and solution as this one? Thanks for any advice. https://www.troublefreepool.com/threads/will-a-new-water-temp-sensor-fix-this-aquapure-swg-scenario.243392/
  13. F

    will a new water temp sensor fix this aquapure SWG scenario?

    Hi all- I have a ~1yr old Jandy AquaPure PLC700 salt cell kit with flow sensor. The AquaLink RS panel, flow sensor, and PDA read as follows: I don't have any error codes. This must have happened recently b/c the pool chemistry tests fine except for low chlorine which led me to check the panel...
  14. 1634229079915.png

    1634229079915.png

  15. 1634229182571.png

    1634229182571.png