Recent content by dc_dick

  1. D

    Trying to diagnose a Hayward RS750 pump

    Updated links. http://cadenlc.net/pool/Old%20Pool%20Electrical%20Conduit.jpg http://cadenlc.net/pool/New%20Pool%20Electrical.jpg http://cadenlc.net/pool/Pre-Shock%2009%20May%2001.jpg http://cadenlc.net/pool/Post-Shock%2009%20May%2006%20-%20Full.jpg
  2. D

    Should I plumb back wash pipe

    Try this link. http://cadenlc.net/pool/Messy%20Pool%20Center.jpg http://cadenlc.net/pool/Filter%20Back%20Wash%20Outlet.jpg http://cadenlc.net/pool/Filter%20Back%20Wash%20Outlet%202.jpg I'll keep in mind the sight glass. Right now, I was planning on connecting a flexible hose from the back...
  3. D

    Trying to diagnose a Hayward RS750 pump

    Here's some pics on what was wrong and some before and after pool pics. ftp://cadenlc.net/Old%20Pool%20Electrical%20Conduit.jpg ftp://cadenlc.net/New%20Pool%20Electrical.jpg ftp://cadenlc.net/Pre-Shock%2009%20May%2001.jpg ftp://cadenlc.net/Post-Shock%2009%20May%2006%20-%20Full.jpg
  4. D

    Should I plumb back wash pipe

    Here's a couple better pictures. ftp://cadenlc.net/Messy%20Pool%20Center.jpg ftp://cadenlc.net/Filter%20Back%20Wash%20Outlet.jpg ftp://cadenlc.net/Filter%20Back%20Wash%20Outlet%202.jpg
  5. D

    Should I plumb back wash pipe

    Worked for me, but here's another site. http://www.linzarni.net/pool/Push%20Pull%20Valve.jpg
  6. D

    Should I plumb back wash pipe

    Hi, Now that I got some of my previous problems solved with the help of this forum, I'm looking to connect the backwash output of my filter to a drain. It currently dumps all the back wash onto the concrete pad that all the pool equipment sits on. The question I have is should I also route...
  7. D

    Trying to diagnose a Hayward RS750 pump

    Quick update. Got the electrical line fixed and the pump motor is back online. Time to shock!
  8. D

    Trying to diagnose a Hayward RS750 pump

    Quick update. I finally measured the voltage going to the motor only 120V is getting to it. Upon further inspection, I believe I have faulty wiring going on one of the lines. I've called my contractor to take it from there. I'll provide an update once all is up and running again.. Spishex...
  9. D

    Trying to diagnose a Hayward RS750 pump

    Called a pool service company today and described my problem to them. They suggested testing the voltage going to the motor. If it was 230, then they suggested replacing the motor. Sound reasonable? I'll call a couple other places just to get a consensus. Also, looking at motors, would item...
  10. D

    Trying to diagnose a Hayward RS750 pump

    Thanks for the word of encouragement.spishex, however, after connecting the pump back, I'm still not having luck. Plus I don't know if I screwed something up upon reassembly. The sound is different now, but the original problem seem to still exist. It's safe to say, it's time to call someone...
  11. Hole below impeller.jpg

    Hole below impeller.jpg

  12. D

    Trying to diagnose a Hayward RS750 pump

    I didn't find any clogs in the suction line using the "drain king". While I was reassembling the impeller, I noticed one of the wires connecting from the "start" capacitor was loose. I was able to solder it back on. I did not notice this when I removed the "start" capacitor couple weeks ago...
  13. D

    Trying to diagnose a Hayward RS750 pump

    I ordered a new run capacitor and replaced the old one, still the same results. I removed the impeller and inspected it for debris or defects, none visible. The next thing I will check is the suction line with the "drain king" as you recommended. As always, any other advice would be definetly...
  14. D

    Trying to diagnose a Hayward RS750 pump

    Finally got around to opening the filter. It was in pretty good condition. But a couple observations. 1. The water level was pretty high. Almost up to the top of the bottom half of the filter. 2. There was a fair amount of DE on the bottom of the filter (i.e not on the filter wings). I...
  15. D

    Trying to diagnose a Hayward RS750 pump

    Ok. I'll take the filter out and clean it out again. Gotta go buy more DE first. If there is DE clumped in the suction line, what would be a good way to un clump it? Because the water going into the pump's basket definetly isn't what it used to be. I did not add DE when backwashing. The...