DBissett's latest activity

  • D
    Our replaster prep starts tomorrow. The pool light is very old, dead, ugly, not repairable, and replacing is costs way too much to be...
  • D
    DBissett replied to the thread Bicarb Startup Question.
    Thanks. Finer measurements with pool empty yielded 3168 cubic feet, or 23700 gallons. Was pretty close. When filled I'll measure at...
  • D
    DBissett replied to the thread Bicarb Startup Question.
    He is planning to trowel the cream off and not do acid rinse. WE did not discuss rinsing it with water. I'm filling so will wait 4...
  • D
    DBissett replied to the thread Bicarb Startup Question.
    I will double check the estimated volume using the usual dimensional formula. With pool empty I did discover it's 8 ft deep instead of...
  • D
    DBissett replied to the thread Bicarb Startup Question.
    TA is 70 but CH is 60. The dosage equations yield values ranging from 90-124 pounds of sodium bicarb, depending on whether you use the...
  • D
    We're getting new plaster tomorrow, Stonescapes Micro, and will do the bicarb startup. Fill water calcium is very low, CH=60, and I'll...