Recent content by Coquitt Steve

  1. C

    Pentair CVA 24 Actuator Died

    My actuator has been intermittent. Changed the micro switches but still intermittent, just in one direction. Took a close look at the 3 position switch at the bottom and saw one of the wire socket plugs loose. Still hanging on but loose. Tightened all the sockets and no more problem. May...
  2. C

    Compool CVA-24 Valve Actuator Issue/Replacement

    I've had this issue in the past, replaced the micro switches but still had an intermittent problem, usually just in one direction. Took a close look at the 3 position switch at the bottom. It has several wires that plug into the bottom and one of these had fallen almost off, hence the...