Recent content by ChristopherDB

  1. C

    Jandy "Alpine White" color temperature

    Does anybody know the color temperature of the "Alpine White" color from their RGB lights? This is the only color I use. I don't need RGB and one of my lights is dead. I'd like to replace it with their white 5000k light to save costs instead of RGB, but only if it will match the white setting...
  2. C

    Jandy Lights

    Is there anything more reliable? I've replaced 10 in 3 years. How has there not been some type of class action against Fluidra? Pool contactor who's a friend of mine says on average he sees them last 1-2 years and replacing them keeps him in business.
  3. C

    ph Dosing pump question

    After the filter it goes to a valve that controls flow between a gas heater and an electric heater (not pictured). Ideally, I would have put the saddle on the pipe connecting the two tees between those black zip ties, but there wasn't enough room to fit it. I ended up mounting the electric...
  4. 1000013837.jpg

    1000013837.jpg

  5. 1000013838.jpg

    1000013838.jpg

  6. C

    ph Dosing pump question

    Looks like a spoke to soon when I said "problem solved". One solution introduces another problem 🤦. Where the return line of the Flow Cell goes to that small pipe for the bubbler in the sun shelf, it always returns to the pool. If I have the spa running, it slowly drains, because the supply to...
  7. C

    ph Dosing pump question

    Taking a guess here. IN suffix is Inductive Load and without the IN the relay would be for a Resistive Load...
  8. C

    ph Dosing pump question

    It can be powered either by 120v or 240v, but if I'm powering the relay from the pump relay, since I don't have a neutral on that I would need to power it 240v?
  9. C

    ph Dosing pump question

    Awesome thank you @JamesW ! Last question. Digikey is out of stock. On Amazon there is a G7L-2A-BUBJ-CB- AC24 (without the "IN" suffix). What does the "IN" indicate and would this be a suitable alternative?
  10. C

    ph Dosing pump question

    Perfect! And adding that relay won't put too much load on that JVA port?
  11. C

    ph Dosing pump question

    So for the actuator that controls the flow from pool/spa on the pressure side, would I splice in the relay to that same connection?
  12. C

    ph Dosing pump question

    I'm thinking I could connect a relay to AUX 7 which I have the skimmer JVA assigned to it. When the skimmer is open, the AUX could be powered and then power the PH doser. Since the skimmer is open the major of the day (except when the cleaner is running) it would give it enough time to run. I...
  13. C

    ph Dosing pump question

    I love this idea. Would simplify everything. Yes I have a suction cleaner which is automated by a JVA on Aux 1. I do not have a relay attached to aux 1 but I have an extra relay I could attach. My dip switch has cleaner OFF. Previously I had it on, but I discovered a bug years ago that Jandy...
  14. 1000013436.jpg

    1000013436.jpg

  15. C

    ph Dosing pump question

    In continuation of my Hanna BL100 project that originated in this thread, I want to add a sensor to the acid doser so that it does not run when the pool is in Spa Mode only. I'm afraid it could cause injury if something goes wrong and overdoses the spa. There's not enough in the tank to really...