    Intellichlor IC40 lights off, D1 light flashing surge board

    Just for the posterity, if anyone will be looking: 1) The voltage 26.9V is apparently sufficient and can run the cell normally 2) I replaced first the surge board (as suggested and since it's much less expensive - look it up on amazon, they have them for $80) - the problem remained. 3) replaced...
  2. A

    Intellichlor IC40 lights off, D1 light flashing surge board

    Thanks a lot, guys! I did measure at the board connector with the cell attached and I already ordered new surge board. I thought the same thing :), board is much cheaper than the new cell :)
  3. A

    Intellichlor IC40 lights off, D1 light flashing surge board

    @mark austin Mark, - have you resolved your issue and what was the problem? I have the same symptoms: all lights off on IC40, surge board has D1 red blinking, D2,6,7 - solid green. Voltage on the surge board connector (red+black) 26.9V @Jimrahbe , - is that voltage too low? anything else I can...