  1. A

    Looking for Aquapure Front Board

    If your board is bad call Salt Solutions and they can repair it. They did mine really fast and warranty the repair for one year. It was cheaper than buying used. Products For Repair : Jandy Aquapure front panel circuit board
  2. A

    Hayward H250 leaves small black things on the bottom of spa.

    When I run the heater small black particles end up in the bottom of the spa. Could this be something from the inside of the heat exchanger? It runs fine and there's no leaks. The heater is about 10 years old.
  3. A

    AquaPure Troubleshooting

    I did a lot of comparison shopping recently for a new 1400 Cell kit and found this seller from Canada to be the cheapest. I live in Michigan and got the kit about four days after ordering it. This picture shows the old sensor but it actiually comes with the latest one that has the box with the...
  4. A

    Hayward H250 Heater Whistles

    Mine does it high or low speed. It appear to be related to the gas flow, not water flow. I hear the whistle right after the gas valve opens, before the burners ignight.
  5. A

    Hayward H250 Heater Whistles

    When my natural gas pool heater fires up it starts whistling. The whistle appears to start as soon as the gas valve opens, before the burners light and doesn't stop until the gas valve shuts off. The unit has been installed for over ten years without the whistle and all the burners have nice...
  6. A

    SWG stopped working

    To see if the generator is working I would take a test from the pool and an outlet with the generator at 100%. Invert the test tube and submerge it to the level of the outlet, then turn the open end of the tube to face the outlet. The tube should fill with water that has been proceesed by the...
  7. A

    Is it OK to use minimum pressure adjustment on Hayward H250 ?

    Current filter pressure is 19 PSI, backwashed last night. Not sure if this helps but my aquapure generates chlorine with the pump on low-speed. I have the new version sensor with the box that has a A/B switch.
  8. A

    Is it OK to use minimum pressure adjustment on Hayward H250 ?

    I have a 1.5 HP Hayward SuperPump with a two-speed motor. For the heater to fire on low-speed the pressure switch needs to be almost completely turned counter clockwise. There is about 1/2 turn left on the the adjustment screw. With this setting the heater shuts off everytime the pump is...
  9. A

    Salt Readings = 25000. Aquapure 1400 stops generating chlorine

    I had been fighting sensor issues for years but the new version with the A/B box is the only one that has worked flawlessly.
  10. A

    Jandy Board Repair

    I have no idea what they fixed. When I sent the board in the power light was the only light that went on and the LCD was blank. With both boards removed the pump ran as normal and all the JVA valves worked with the remote as usual.
  11. A

    Jandy Board Repair

    My Aqualink had a bad front board for the Chlorine generator. Jandy no longer makes the board and they wanted me to replace the whole system for over $600 ! I looked on Ebay for my specific board and only a few were available. They few I did find, people were wanting close to $500. I ended...
  12. A

    Looking for Aquapure Front Board

    I installed a new cell and sensor in my PureLink System last night and ran into some issues: 1. After installation, everything appeared to be working except the salinity was reading 4100 when multiple water tests indicated it was 3000. With the Salinity so high the cell would not go on. 2...
  13. A

    Installation of new vesion Aquapure 1400 Questions

    I have a PureLink system that currently has the Aquapure installed with the Tri-sensor adapter board. My Aquapure version is 11230A05 and I have an AKC13 front board. I just purchased a new cell and sensor (new version with the external Program A and B box) and have a few questions. 1. The...
  14. A

    Aquapure 1400 - Replace cell or cell and sensor

    My cell is due to be replaced and I am debating on buying the cell or the kit with the sensor. One issue I have had off and on has been the no flow error when running the pump on low speed sometimes. My current set-up has the Tri-sensor adapter (Small Board) with clear cover but not the...
  15. A

    Hayward Millivolt heater doesn't always fire up with Jandy Aqua Link

    I think the issue may be resolved by replacing the wires going from the heater to the Aqualink control panel again. I noticed the wires ran very close to the pump motor so I got the same gauge wire but with significantly more insulation on it. Now it appears to be running fine. Sent from my...
  16. A

    Dolphin Diagnostic Bird's Nest Tangling

    I have had the same tangling issue since day one. I found a place that called Maytronics and they said the part in the link below could be retrofitted to an older cleaners cable. I work in the electronics industry and just ordered the part. It was only $45 delivered so I thought it was worth...
  17. A

    Hayward Millivolt heater doesn't always fire up with Jandy Aqua Link

    Over the last couple years, my heater won't fire using the Aqualink all the time. My thermocouple is generating millivolts within specification. When I try jumping all the safety devices it still won't fire. When I use a jumper on the gas valve it fires up every time and then stays on like it...
  18. A

    Hayward 300 millivolt intermittent with Jandy

    My thermocouple is putting out 480 mvs yet the heater won't fire unless I jump the terminals sometimes. Once jumped it stays running until the temp is reached so I know all the safety switches are ok. I have about 5 feet of wire running to the Jandy Aqualink. Is there special wire I should be...
  19. A

    Jandy Aquapure "Service" light on low speed

    I tried pushing the calibration button while on low speed but the issue is still there. Just to be sure I went through the whole procedure for installing a new sensor with the Tri-Sensor Adapter board. 1. My Aquapure version is 11230A05 and I have a AKC13 front board. 2. The instructions say...
  20. A

    Jandy Aquapure "Service" light on low speed

    Ever since I installed a two speed motor last year my Aquapure hasn't run consistently since. If I set the PDA to start low speed in the morning the motor starts on high for a while then switches to low as it should and the Aquapure service light comes on. If I set the high speed to run for...
  21. A

    Aquapure Tri-flow Sensor Error

    I did the calibration with good flow and the adapter board was light up. Last night I removed the jumper and everything started working, I didn't even do the calibration procedure. The adapter board "Flow" indicator was flashing and the flow indicator on the Aquapure is solid green. When I...
  22. A

    Aquapure Tri-flow Sensor Error

    I did press the calibration button for 5 seconds like the instructions said.
  23. A

    Aquapure Tri-flow Sensor Error

    I installed a new Aquapure cell about three years ago (New Style). A few weeks ago it stopped generating and the display had 172 and 186 error codes. I ordered a new sensor that came with the Tri-Sensor adapter board and then found out my set-up required a special cable due to a lack of...
  24. A

    Single or 2 speed pump??

    I upgraded my pump to a 2 speed motor this year and it was a huge improvement over the single speed. Not only is our electrical usage down significantly but we can barely hear it run. I also contacted Hayward about running the heat with the pump on low speed and they said it was OK to do so...
  25. A

    Where to point the outlets !

    I have had my pool for almost 10 years and to date don't know how to point the outlets so dirt does not settle in large quantities on my steps and in a corner on the deep end. I have tried pointing the outlets in every direction possible and the dirt ends up in the same two spots. I also tried...
  26. Pool2.jpg

    Pool2.jpg

  27. A

    Aqualink Pump Speed when Heater running

    I have a two speed pump connected to my 10 year old Aqualink system. If the system is running in low speed and heat is called for the heater wont fire up. Is there a way to program the pump to ramp up to high speed when heat is called for ? My heater is a Hayward 250,000 milivolt with a...