Search results

  1. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Initially had it on boost (100% for 24h). With appropriate levels as of 36 hours ago turned it down to 50%. Edit: 75% x 12 hours
  2. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Hi @mknauss. Took your advice and added liquid chlorine. Per the instructions, we were able to get a free level of three. Continued with the SWG. Unfortunately, now about 36 hours later showing no free chlorine again. Stabilizer also looks a bit low. Would that be the cause of no...
  3. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Well, just to close the loop here, I ended up ordering a new salt cell. Upon further inspection of the old one, the central plate does seem to be somewhat degraded. It's certainly not gone entirely, but it's quite jagged at the end. I don't know the age but my estimate is that it's at least...
  4. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Anyone have any other suggestions? Either this is an issue no one has ever seen, or I"m not explaining it righ t.... For what it's worth and for future reference - a few additional things I have learned: There is no front and back board anymore. Jandy replaced the front/back board setup...
  5. R

    Pros and Cons to SWG

    Sorry, I don't have an answer to your question but I did want to say "Go Irish!"
  6. R

    Jandy Aquapure error code 170

    Were you getting a no-flow error?
  7. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Hi all - So I received the replacement board (back board I believe .... R0467600) and reinstalled it this morning. Good news is that my previous error codes are now gone (125/194). Bad news is that I have two new error codes to replace them! (170/193). Reading through the tech manual...
  8. 20230808_115130.jpg

    20230808_115130.jpg

  9. 20230808_115657.jpg

    20230808_115657.jpg

  10. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Interesting. So if this is the rear PCB, where is the front PCB? I do not see another board. In looking at the workbook, it seems to me The front / rear board configuration must have been an older configuration. It is listed as such in the workbook. The board referenced first in the workbook...
  11. R

    Zenith/Jandy SWG Nature2 FusionSoft 1400 Error Codes

    Hi All - hoping for a little help diagnosing my salt water generator system. I've done as much troubleshooting as I can and getting some confusing results. I have the Jandy Aqualink connecting to a Zenith Nature2 Fusionsoft 1400 SWG. My wife, primary caretaker of the pool, noted to me she was...
  12. 20230803_132113.jpg

    20230803_132113.jpg

  13. R

    Spa filter stuck

    Thanks @Mdragger88. I will look into that. So I ran it without the filter overnight, to see if I could replicate the FL-1 error again. When I inspected the tub this morning, temperature was fine and the waterfall was running as expected. Upon starting the jets however, The FL-1 error returned...
  14. R

    Spa filter stuck

    Hello again - So I've been working to bring the spa chemistry into acceptable ranges. However, still getting an intermittent flow error. At this point, I believe that the filter probably needs replaced. When I run it without the filter and place it seems to do just fine. Any suggestions on...
  15. R

    Spa filter stuck

    So by way of followup .... I did get the filter out. It took 2 channel locks and a lot more forced than I had ever thought but eventually got it loose. In the meantime, the lines had frozen because the temp dropped. But after space heating my way to unfrozen lines, refilling part of the...
  16. R

    Spa filter stuck

    Hello again everybody. So I did obtain and try some strap wrenches today. Unfortunately did not work. I think it's a surface area issue. The elevated projections on the nut keep the wrench from gripping a whole lot so it just slips as I try to pull hard on it. A few times I did get some...
  17. 20221210_174638.jpg

    20221210_174638.jpg

  18. 20221210_174644.jpg

    20221210_174644.jpg

  19. R

    Spa filter stuck

    What Joe said below is correct. It's a two-part filter, one part is cleanable on the left, the other part is one time use and gets replaced every three or four months. That plastic winged nut thing is what is stuck. It's part of a pretty inexpensive piece that I believe pulls water into the...
  20. R

    Spa filter stuck

    Sure - thanks for tagging him. I'm assuming he's the expert in these parts. :-) I'm open to anything at this point. I rarely get flummoxed like this....
  21. R

    Spa filter stuck

    Hi all - I hope I'm posting this in the right location. I have a Sundance Chelsea 780 spa. We've had a down for a few months because of an electrical issue, have had a very difficult time getting electrician to come help us. Long story short, the electrical issue is addressed. I refilled...
  22. 20221209_142214.jpg

    20221209_142214.jpg

  23. R

    Another Jandy upgrade question

    Got it. Thank you both VERY much for the input. We don't have any "schedules" per se as of yet - need to work on all of that. As I said we are brand new to this, pool open for less than a week and the first pool we own. Wife is very interested in the Alexa skills, doesn't like the PDA...
  24. R

    Another Jandy upgrade question

    Thank you very much ajw! Someone earlier in the thread mentioned that when I would install this upgrade kit, there would be a significant amount of "reprogramming" that I would need to do. Is there a resource for learning how to do that reprogramming? I'm comfortable with circuit boards and...
  25. R

    Another Jandy upgrade question

    Makes sense. So something like this would be what I'm looking for?
  26. R

    Another Jandy upgrade question

    So looking at the panel there's none of those buttons. I was able to pull this up on the PDA. Model PDA-P4 Type Only Firmware PDA 7.1.0 JBox 4.0 Handheld 3.0
  27. 20220603_223100.jpg

    20220603_223100.jpg

  28. 20220603_223510.jpg

    20220603_223510.jpg