Search results

  1. P

    Are copper ionizers worth it?

    I should have asked here first, guys :( But I trusted thousands of great reviews on Amazon...
  2. P

    Are copper ionizers worth it?

    Hello, You guys have probably heard about copper ionizers, like this one: https://www.amazon.com/gp/product/B00IIXKL6O/ref=ppx_yo_dt_b_search_asin_title?ie=UTF8&psc=1 I got 2 of them and I don't really see copper levels increasing, so I'm afraid to decrease my chlorine levels. Also, here are...
  3. P

    Pool lost water down to the bottom of the skimmers - New Jersey, US

    Thank you. I added more water, turned on the pump and turns out a pipe above ground cracked. Thank God, will be easy to fix.
  4. P

    Pool lost water down to the bottom of the skimmers - New Jersey, US

    Hello guys, I wanted to swim today (I have a heater, so water is almost 90 degrees), but found that my pool has lost water down to the bottom of the skimmers. I swam 2 days ago and everything was fine. I also didn't see any water loss (or didn't notice) yesterday. I don't think we had freezing...
  5. P

    Spa's GFCI trips immediately

    Update: So... after I dried up the spa internals with an electric heater & a fan, reconnected all the cables/wires, replaced 2 leaking unions & added some scotch tape to prevent water from getting inside, my spa is finally working! It was working the whole evening yesterday, and has been working...
  6. P

    Spa's GFCI trips immediately

    Here's an update guys: In the previous episode: ...Started tripping again, without any rains. I tried to disconnect everything on the board and connect again and it started working immediately after that (suggesting bad connection somewhere).... In the latest episode: But later it stopped...
  7. P

    Spa's GFCI trips immediately

    Why? The pump is for the pool, not for the spa.
  8. P

    Spa's GFCI trips immediately

    Thank you. It was tripping even when everything on the left side & the heater (2 wires in the top right corner of the board) were disconnected. It made me think something on the board itself was tripping. So I started unplugging everything on the board one by one. And eventually, the GFCI...
  9. P

    Spa's GFCI trips immediately

    Thank you. Yesterday the GFCI started tripping again, although there was no rain and everything looks dry. I disconnected a lot of cables/wires from the board and on the board and it started working again. So it seems the reason is not a water leak but a bad connection somewhere on the board...
  10. P

    Spa's GFCI trips immediately

    Ok, guys, finally 3 months later, I got time to look into the hot tub issue. To my surprise, when I tried to turn the GFCI on, it didn't trip. I tried turning on the spa and it did, jets & lights were working. But I quickly noticed that it was leaking from the union connecting the heating...
  11. P

    Heater turns off quickly with "Rollout sw open" error. Also "flame noise" is too much?

    Turns out it is a DIY project for someone without experience in servicing gas heaters :) I replaced the pilot: https://www.amazon.com/gp/product/B003ZTQMUU/ref=ppx_yo_dt_b_asin_title_o00_s00?ie=UTF8&psc=1 the tension wire...
  12. P

    FC 9, CYA 30 - May I swim?

    Hello, I accidentally increased FC too much, FC is 9 ppm now, CYA is 30 ppm. May I swim, or I have to decrease FC or increase CYA first? If I shouldn't swim now, what the minimum FC for CYA = 30 I should swim with? Kind regards, Pavel
  13. P

    Heater turns off quickly with "Rollout sw open" error. Also "flame noise" is too much?

    Thank you. I'm willing to try to reanimate it and use it until it dies completely. I took the heat exchanger off, cleaned it up with a pressure washer and cleaned everything I could reach in a heater with a pressure washer. See the 4 pictures below of how it looked after cleaning. I cleaned the...
  14. 1654272667237.JPEG

    1654272667237.JPEG

  15. 1654272673897.JPEG

    1654272673897.JPEG

  16. 1654272669290.JPEG

    1654272669290.JPEG

  17. 1654272672515.JPEG

    1654272672515.JPEG

  18. P

    Spa's GFCI trips immediately

    Thank you, will try soon!
  19. P

    Spa's GFCI trips immediately

    @RDspaguy Yes, the GFCI breaker trips while my hand is still on it or within a few seconds after I release it. As I said, it trips even if everything is disconnected from the board, i.e. I tried disconnecting all these connectors: Although I don't see a label for heater connection here.
  20. 1654115873137.png

    1654115873137.png

  21. P

    Spa's GFCI trips immediately

    Hello, While I was on vacation I left my spa in the "Sleep" mode. When I came back, the spa wasn't working and I saw that the GFCI trips immediately. I opened the spa, disconnected power cables and the GFCI doesn't trip anymore. But when I connect the high voltage cable - it trips (doesn't trip...
  22. 1653950787901.JPEG

    1653950787901.JPEG

  23. 1653950792003.JPEG

    1653950792003.JPEG

  24. 1653950779555.JPEG

    1653950779555.JPEG

  25. 1653950783456.JPEG

    1653950783456.JPEG

  26. 1653950772645.JPEG

    1653950772645.JPEG

  27. 1653950776326.JPEG

    1653950776326.JPEG

  28. 1653950763350.JPEG

    1653950763350.JPEG

  29. 1653950771127.JPEG

    1653950771127.JPEG