Search results

  1. T

    ic40 life check and blinking green high salt

    ha. true. Im more of a scorched earth when it comes to pool cleanliness. There is some algae that I see developing so I might as well slam it. thanks for the insight about the 2.5 min cycle test. should I just ignore the high salt warning as I've validated at the pool store and via taylor...
  2. T

    ic40 life check and blinking green high salt

    thanks Jim. i purchased the unit in april 2019. I checked the lights at 50% and it cycles on/off every 2.5 mins...... ive run the tests.... FC 2 Ph: 7.6 TA 60 CH 350 CYA 60 Salt 4000 water temp 85F me: stumped. perhaps do a SLAM?!?
  3. T

    ic40 life check and blinking green high salt

    thanks. i used this for reference prior to posting.... i thought i read somewhere on TFP that when using ic40 with easy touch, the buttons on the intellichor do not work....so how does someone test the remaining life if that is the case? Peter.
  4. T

    ic40 life check and blinking green high salt

    Hi and happy Friday i have a ic40 with the easytouch. how do i check the remaining life? pressing on the "More" button does not do anything. i've looked on youtube and can see that pressing More after three seconds scrolls the LEDs. it is not producing any chlorine. mine does nothing. any...
  5. T

    Pentair master temp 400 manifold

    Yes. I took it off to clean and check on the diverter after replacing the HLS. It was rusted on the inside of the manifold.
  6. T

    Pentair master temp 400 manifold

    Does anyone know what this does and what part number to replace on the manifold? Was cleaning manifold and saw that this is rusting on the inside.
  7. B96AF692-EEE5-4C1E-AE55-0A70B8D5936B.jpeg

    B96AF692-EEE5-4C1E-AE55-0A70B8D5936B.jpeg

  8. T

    power went out and pool pumps iced up - how to thaw?

    how do i thaw out a pool pump that iced over? thanks. power went out around midnight SUnday/Monday. and the pumps stopped and froze. power is back on so i wanted to thaw out so i can run as cold temps are expected again in houston tonight.
  9. T

    Pool sleeve repair

    Keith, The sleeve is pvc. It seems the cement holding in the sleeve was compromised and no longer holds it in place. Some of the dirt inside the hole washed out so i need to backfill and re-seat the sleeve. the umbrella fits snug/nicely in the sleeve. Am looking for recommendations on how...
  10. T

    Pool sleeve repair

    Here are a couple of pictures of the sleeve. In the deck and pulled out. Thanks!
  11. 5B2BF5B7-9281-4818-8B9E-1BD863B6D5A5.jpeg

    5B2BF5B7-9281-4818-8B9E-1BD863B6D5A5.jpeg

  12. 80CA23B3-83BC-4B2A-ACD8-9C0D23EB0367.jpeg

    80CA23B3-83BC-4B2A-ACD8-9C0D23EB0367.jpeg

  13. T

    Pool sleeve repair

    thanks Steve. the sleeve is in the pool deck and not in the pool. I noticed the umbrella in the sleeve was tilting and took the umbrella out of the sleeve to find that the sleeve is loose (in the deck). I am able to pull the entire sleeve out of the hole in the deck. I am hoping I can...
  14. T

    Pool sleeve repair

    Hi folks, I have an umbrella sleeve that popped out from the concrete...what's the recommendation on how to repair? The deck looks to be 3-4 inches deep and the sleeve definitely hits dirt. I can take some pics later this evening. Thanks in advance! Peter
  15. T

    Pentair CVA 24 Actuator Died

    woke up this morning and saw all the water overflowing from my spa into the pool instead of a light trickle. Found that one of the two actuators had a problem. microswitch ended up being the problem based on diagnosis derived from this thread. Thanks to the contributors and moderators. 20...
  16. T

    New IC40 Flow Light Red after a week

    Yes..doing it as we speak. it was the filters. everything works great now. Thanks Jim!
  17. T

    New IC40 Flow Light Red after a week

    yes there is a bunch of that...pool is still brownish...so i need to clean the filters, then clean again after the algae? this is the first time i've ever had algae....thanks.
  18. T

    New IC40 Flow Light Red after a week

    Thanks for the quick reply Jim. I just cleaned the filters a month (they are about 5 years old but do not have any tears and the binding straps are still good). but just looked at the filter pressure and it may be the problem. i'll clean filters tomorrow and hope that that solves the issue...
  19. T

    New IC40 Flow Light Red after a week

    Hi all, i got a new IC40 to replace and old one after 6 years! replaced and it worked no problem for 3 weeks or so. I was out of town for a week and returned to a green pool. It had rained a lot in Houston so i added the necessary salt to 3700. the red flow light is on and my variable pump...
  20. T

    Polaris 280 too buoyant?

    Hi, I have this problem and have checked for the “kidney stone”...it’s clear. What else have you all tried? Ball float has no water in it and is .75 inches from the post. Not sure what else I can do. Thanks in advance....
  21. T

    New Pool Calc for iOS

    Is the poolcalculator.com the same is the https://www.troublefreepool.com/calc.html ? the only difference is the font and that the recommendations for CH for plaster pools is different. poolcalculator.com has Goal: 250 to 350 while https://www.troublefreepool.com/calc.html has Goal: 350 to 450...
  22. T

    Muriatic acid cost

    11 bucks for two 1 gallon containers 31.45% at HD in woodlands tx
  23. T

    PB4 Booster Pump troubles....

    Thanks for all the help folks. Replaced another capacitor on the PB4 with 124-149MFD 165VAC and ensured that the booster was primed....voila!
  24. T

    PB4 Booster Pump troubles....

    Tried again....and it was making the loud buzzing noise.
  25. T

    PB4 Booster Pump troubles....

    i can turn it on temporarily Check. Now it just blows the fuse... Replaced the cap with 125-149mfd and 125vac The original was 165vac Would that cause the breaker to flip?
  26. T

    PB4 Booster Pump troubles....

    impeller is fine after taking off six bolts and confirming it is spinning with shaft. I also looked in the volute and no obstructions. However, it is easier to spin than a new pump. and it makes a squealing noise when i rotate. is that indicative of a bad motor?
  27. T

    PB4 Booster Pump troubles....

    Thanks. Would I need to get any resealer/kit after I take the housing off?
  28. T

    PB4 Booster Pump troubles....

    I have a 5 year old Pb4 booster pump that stopped working. I checked the back and it spins freely. I replaced the capacitor and it now runs. However, it runs quieter than i remember and there is no water coming out of the jet where i connect the cleaner. Any ideas on the next step to...
  29. T

    Pentair MasterTemp 400 Error code E05

    You are more right than wrong on your statement. Being a newbie, i opened up the panels on the MasterTemp to find a couple of mud dauber nests against the air blower vent...cleared out with a blower and VOILA....No more E05. Thanks for the tips PC!:joker: