Search results

  1. D

    Panel no longer controls heater

    Solved: Closing this out in hopes someone in the future. Issue was the control board behind the control keypad. New $25 board off Amazon corrected the issue.
  2. D

    Panel no longer controls heater

    Ok, I’ve opened up the heater verified 120vac & 24vac at the transformer pin connector at the board, fuses aren’t blown. I’m half way through Haywards troubleshooting guide. Interestingly , after cycling the breaker the panel service light and the display are rapidly flashing. The display is...
  3. IMG_0112.jpeg

    IMG_0112.jpeg

  4. D

    Panel no longer controls heater

    Hi All, Via a little more troubleshooting and research I've eliminated the EasyTouch as the issue. I am able to measure 24vac when the panel is not commanding heat and 0vac when the panel is commanding heat. I can perform a continuity test if necessary, however the conductor between the panel...
  5. D

    Panel no longer controls heater

    Hi, DW wanted to use the spa today, however the heater failed to fire after putting the system in “SPA“ mode. So far, I have: - Verified sufficiently high set point for spa temp - Verified app and panel indicated heat was being commanded - Manually turned on heater; verified fan, ignition and...
  6. D

    Screenlogic2 Password Reset

    Marty, This did it. I had my adapter on my IOT VLAN, I had switched it over to the main LAN to see if I could get access but was still blocked. I then rebooted the adapter so it would release the VLAN IP and grab the main LAN IP and I was able to access locally and remove the password...
  7. D

    Screenlogic2 Password Reset

    ajw22 - Can they reset my password or am I looking at a full factory reset of the entire system? I take it Pentair customer service isn't available on the weekends?
  8. D

    Screenlogic2 Password Reset

    After setting the password in the Screenlogic setup on my PC I also lost access from my mobile devices, so I’m confident that the password is stored somewhere with Pentair.
  9. D

    Screenlogic2 Password Reset

    Marty, Unfortunately I got into this whole mess using the ScreenLogic Connect program from my PC. That is what I am now locked out of. App doesn't work either, but that because I can't duplicate the password.
  10. D

    Screenlogic2 Password Reset

    Unfortunately the password option at the panel is only to setup a 4 digit numeric code. So no luck.
  11. D

    Screenlogic2 Password Reset

    Let me check to see if I can access it from the panel.
  12. D

    Screenlogic2 Password Reset

    Via Local from the app? I’ve never been able to get that to work. My only access has been through remote.
  13. D

    Screenlogic2 Password Reset

    Hello... in setting up my PC access via ScreenLogic connect I must have fat fingered the password because I can no longer login to ScreenLogic Connect. The system has worked for months and I was screwing around in the interface and decided to setup a password. Apparently I fat fingered the...
  14. D

    New Pump for In - Floor system

    Anything you don’t like about the Pentair system? Is your controller accessible via WiFi?
  15. D

    New Pump for In - Floor system

    Chiefwej… thanks for the response. That was one of my concerns, if I removed the valve body, would be enough pressure to for the pop-ups to “pop” without running the pump at high speed constantly. May I ask your run schedule and RPM’s? Did you leave the nozzles in your pop-ups when you pulled...
  16. D

    New Pump for In - Floor system

    I need to replace my existing pump, which I hope I can limp it along to the off season. With the new pump, I’m also going to upgrade our automation. I’m fairly settled on the Intelliflo series of pumps, which seems to get high praises on this board. Here is the rub, my only plumbing returns...
  17. D

    Seal Plate Gasket Failures

    OP here - Smoked another gasket yesterday, this one failed a little more than five weeks.
  18. D

    Seal Plate Gasket Failures

    Hi James… I agree it’s time for a new pump. I’m trying to figure out what I can do with my Caretaker system so I don’t need such a hog of a pump. As for photos, unfortunately I threw the gasket away in disgust. I have noticed that previous leaking gaskets had a bit of a candy cane stripe in...
  19. D

    Pop up system and Pumps

    I have a five zone Jandy pop up system that is the only supply for my pool, with the exception of my spa spillover. I'd like to downsize this hungry single stage 2.7HP pump to a VFD or dual speed at a minimum. We bought a robot last season and have found that it easily out performed the pop-up...
  20. D

    Seal Plate Gasket Failures

    I have a older Hayward Northstar pump that keeps eating seal plate gaskets. Generally, the gasket will last a season, and when the gasket had previously failed there would be a loss of vacuum once the pump shut down, but no loss of water while the pump was operating. Fast forward to yesterday...
  21. D

    What’s causing my stone to break down?

    The stone under the spillover appears to be the same material as the adjacent stone. However, we purchased this home with the pool and thus have no knowledge of what materials were used.
  22. D

    What’s causing my stone to break down?

    The stone itself. The stone just outside of the spill over has lost its veneer, and is breaking down. The “stone” seems to be a week pea gravel concrete mix that is crumbling into the pool now that the veneer is gone.
  23. D

    What’s causing my stone to break down?

    Bump. Any more thought? I want to repair this condition and prevent reoccurrence.
  24. D

    What’s causing my stone to break down?

    Curiously the breakdown of the stone is outside the spillover “area,” and the stone directly under the spill over appears to be in good shape. To your point, unfortunately the only pool return I have is via an in floor pop up system. One of the zones is in my spa, so whenever I run the pump...
  25. D

    What’s causing my stone to break down?

    Noticed that the “faux” stone veneer, or at least what I assume is veneer, is breaking down on either side of the waterfall feature from our spa to the pool. Any idea what would cause this, and how to prevent it in the future?
  26. D8A1C44D-D951-48E5-99F6-1A5010ACD4C9.jpeg

    D8A1C44D-D951-48E5-99F6-1A5010ACD4C9.jpeg

  27. D

    Pressure side leak?

    It appears the leak was caused by the seal plate o-ring. Replaced the o-ring, primed and ran the system for a few minutes. Shut down the filter and and everything seemed to hold.
  28. D

    Pressure side leak?

    Thanks Jim...much appreciated everyone. I’ll let you know how it goes.
  29. D

    Pressure side leak?

    Thanks... is rebuilding an actuated Jandy valve substantially different than rebuilding a manually operated diverter valve?
  30. D

    Pressure side leak?

    Sktn, MPV seals? I am unfamiliar with the term.