Search results

  1. I

    Booster Pump recomendations? (Polaris TR28P pressure side cleaner)

    Title says it - gotta replace a very old booster after already replacing the very old vac. Vac is a polaris TR28P (been very satisfied with it so far, it does did a great job with pine straw, before the pump eviscerated itself). Polaris recommends their PB4SQ booster. Claims of efficiency...
  2. I

    Minimax NT parts available - mostly new

    If this is the wrong place to post this please let me know and I'll be happy to move it. I made several efforts to save my Minimax NT 400 and all I have to show for it are some new parts. They are very lightly used since the heater only lasted about another month after install. They're...
  3. I

    Raypak - Cupro Nickel or ASME copper?

    EDIT again: apparently raypak does not have a low-nox AND cupronickel option. (Learning as I go.) Back to the drawing board.
  4. I

    Raypak - Cupro Nickel or ASME copper?

    EDIT: cupronickel is available as an OPTION on the ASME models. So....still, is ASME overkill for residential? Thanks again.
  5. I

    Raypak - Cupro Nickel or ASME copper?

    Replacing minimax NT 400 (400k btu) and going with RayPak low nox heater. There are two options and I am hoping to get some advice about which to choose. I can either get the ASME model that has copper heat exchangers, or go with the cupro nickel heat exchanger version that is NOT ASME. I...
  6. I

    New in ground heater brand questions / recommendations

    This is not a solicitation for recommendations of any particular model - I understand that models need to be selected specifically to handle the pool size/region/etc/etc/etc. If my prior posts are any indication, I've met my match when it comes to our very old MinimaxNT and have decided that...
  7. I

    Is a Solar Heater possible if my pump equipment is not next to the house?

    So is there basically a distance restriction? I mean, there's gotta be since you're moving hot water and losing heat as you go, but I guess I'm wondering just what is it? Or how well would insulation help out. If it's the case that I can run it that far, my garage roof would be absolutely...
  8. I

    Is a Solar Heater possible if my pump equipment is not next to the house?

    I imagine the answer is always going to be that anything is *possible*, but I'm wondering more what's practical or efficient. I've included a (very professionally drawn) picture of the roof, equipment location, and usable roof space. Equipment circled, red line to house represents about 40...
  9. Screen Shot 2019-04-16 at 7.19.04 AM.png

    Screen Shot 2019-04-16 at 7.19.04 AM.png

  10. Screen Shot 2019-04-16 at 7.28.03 AM.png

    Screen Shot 2019-04-16 at 7.28.03 AM.png

  11. I

    Wits End with Minimax NT

    The motor itself is brand new, but of course it does run at a lower speed. I'm fairly confident there isn't a blockage - i checked the pipe. Tell me if this is a thing - the run capacitor on the motor is slightly smaller than the one on the 3400 RPM motor, but the motors themselves seem to be...
  12. I

    Wits End with Minimax NT

    I've got an old Pentair Minimax NT that I've dumped a modest amount into reviving, and it's worked for a while until now and I'm totally stumped. Heater worked fine the first two years we were in the house. It had some issue come up that led me to open it up and discover just a ton of rust and...
  13. I

    [SOLVED!]: Sundance Flow Motor Head Scratcher

    Re: Sundance Flow Motor Head Scratcher Update: It's a 2006 Sundance Cameo. Flow motor still not powering on (everything else does), but I've done some more trouble shooting. First, with the tub empty I removed the flow switch and "tested" it. (Basically turned on the tub and closed the...
  14. I

    [SOLVED!]: Sundance Flow Motor Head Scratcher

    UPDATE: Found a post from Feb 2013 on whatthebest-hottub.com referencing the K10 relay on a Sundance spa. Apparently not a terribly uncommon failure that many folks fix by purchasing a new circuit board. HOWEVER, there's a way to wire the circ pump to another relay by switching the terminals...
  15. I

    Minimax NT E04 Error - solved, gas manifold?

    It is, and has been reattached. And it still seems to be running like normal. I've only tested for a few hours here and there since its summer and not really necessary. I guess I was just surprised (1) that it was something that simple and (2) that it gave an E04 error which, if I've read...
  16. I

    Minimax NT E04 Error - solved, gas manifold?

    Other than one small screw hole being rusted a little bit, the rest of the heater is in fairly decent shape all things considered. The exchangers don't leak. The flue collector, while plenty rusty on the inside, has been repaired and is fully intact. The motor runs fine, the burners all...
  17. I

    Minimax NT E04 Error - solved, gas manifold?

    TL;DR: is it possible that my E04 code is being caused by the gas manifold simply falling out of place causing the burners not to ignite? So far, propping up the manifold (where it normally falls open because its screw hole is rusted) seems to be all that's needed to fix* my annoying E04 code...
  18. I

    What if my salt level is at 6000?

    Nothing's broken, everything works, salt level is 3200. But it made me wonder, what would happen if my salt level was twice that? Would the salt deteriorate the pool? The plumbing? Would the chlorine generator still make chlorine? Would algae, etc even grow in that?
  19. I

    Flow Motor - Capacitor or whole pump?

    I've got a buzzing flow motor and a "FLO" error on a spa. I switched out the capacitor with one that I have not been able to test yet, so I can't vouch for it, and I get the same buzzing. I can't take a cap off of either of the other motors because the covers are sealed shut. Obviously it's...
  20. IMG_0020.jpg

    IMG_0020.jpg

  21. I

    Adding automation to older system

    Currently have a Hayward Aqualogic PS-4 (SWG, looks like this one ). I've been reading a lot about the apps and home automation related resources with pools and spas and was wondering if there was any way to retrofit any kind of automation or wireless/phone based control to this kind of system...
  22. L1120865.jpg

    L1120865.jpg

  23. I

    Can I replace single speed motor with variable? Is it feasible?

    Thanks for the input. Requested some more info from Inyo Pools. They seem really good about their support and whatnot. Any suggestions of other retailers check with? This is the first bit of actual equipment I'll be replacing, so I don't have a lot of experience on that end. Thanks!
  24. I

    Can I replace single speed motor with variable? Is it feasible?

    Still learning a bit about all of this. What does this mean: "The pump wet doesn't add anything to efficiency. In fact the Intelliflo uses the same wet end as the Whisperflo WFE-12." As this just saying that the only thing different between the IntelliFlo and WhisperFlo is the "dry end", aka...
  25. I

    Can I replace single speed motor with variable? Is it feasible?

    Current pool pump is a Pentair WhisperFlo 1.5 HP single speed. For all intents and purposes the pump is fine but the motor is showing its 7-year age. (1) Can I replace just the dying single-speed motor with a variable speed motor? (2) Is that even worth it, or does replacing the whole pump...
  26. I

    '06 Sundance Spa - Heater or Recirculation Pump Capacitor?

    Re: '06 Sundance Cameo main fuse blowing Well, this issue seems yet unsolved:https://www.troublefreepool.com/threads/131093-06-Sundance-Spa-Heater-or-Recirculation-Pump-Capacitor?p=1158749#post1158749
  27. I

    '06 Sundance Spa - Heater or Recirculation Pump Capacitor?

    This is continued from another thread where I "figured" that the issue was with the heater...or was it? https://www.troublefreepool.com/threads/130853-06-Sundance-Cameo-main-fuse-blowing Either way, the issue occurred again where the main fuse blew and tripped the breaker. This time I dug a...
  28. I

    '06 Sundance Spa - Heater or Recirculation Pump Capacitor?

    Re: '06 Sundance Cameo main fuse blowing UPDATE: Some research revealed that IF the breaker also trips when the fuse blows, that is most commonly a sign on Sundance spas that the heater is going bad. Heaters are fairly simple to replace and run around $200, so I preemptively bought one...
  29. I

    '06 Sundance Spa - Heater or Recirculation Pump Capacitor?

    '06 Sundance Cameo main fuse blowing Got home from vacation to find no pumps or filters running. Checked and the breaker was tripped. Flipped it on and noticed the same except also my control panel going a bit berserk, though not showing any actual codes. Flipped breaker off and on once more...
  30. I

    Is vacuuming required?

    Any suggestions on vacuums that won't totally break the bank? Like I said, I don't have a debris "problem" and the pool is not all that big. In others' experience, how much vacuum is necessary to do a good job?