Goldline Aqua Rite with T15, intermittent issues?

denofa

Active member
Feb 7, 2024
33
North Carolina
Pool Size
20000
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
Hayward Aqua Rite (T-15)
Hey all. I am working on getting my SWCG up and running so I can start enjoying my pool season. Disclaimer: I recently bought this house and it was a heavily-neglected foreclosure, most of the pools equipment seems in good shape but I can't verify the age or use of the salt cell.

Before trying to use the system, I cleaned the cell manually and with diluted muriatic acid to clear out the minimal scale. I tested out the SWCG a few weeks ago and it seemed to work: all diagnostic measurements were within spec, I saw bubbles from my return jets, but I didn't run it long enough to verify it was working as I was just starting my SLAM.

Last night, I measured my FC at 9 and salt at 3200pm. I set the switch to "Generate" to start getting a baseline at 50% after 8 hours of runtime overnight, and I found that my FC hadn't changed at all. When I checked the control panel, both "Inspect Cell" and "Check Salt" were flashing. After holding the diagnostic button to clear the "Inspect Cell," I toggled it off and on, set the dial to 100%, and confirmed it was generating (bubbles out of return jets).

I'll keep monitoring to see how it works, but is there anything else I can check before/when I get in the Inspect Cell/Check Salt situation again? As I have a ~20,000 gallon pool, it looks like I'll need another 40,000 gallon rated cell if I'm due for replacement.

Thanks!
 
This is the basic information we need to know in diagnosing a problem:
  • Report all diagnostic readings when you..
    • Move the switch from auto to off and check all of the readings.
    • Move the switch back to auto and recheck the readings.
    • Move the switch to off for a minute and then back to auto and recheck the readings.
  • What are the first seven characters of the cell and box serial numbers?
  • What is the actual salinity and how are you measuring it?
 
  • Like
Reactions: denofa
With generator off:

Pool temp: 74
Cell voltage: 31.7
Cell current: 0.00
Desired output: 100P
Instant salinity: -0
Product name: AL-0
Software revision: r 1.59


With generator auto:

Pool temp: 74
Cell voltage: 26.3
Cell current: 6.00
Desired output: 100P
Instant salinity: -3100
Product name: AL-0
Software revision: r 1.59


With generator auto after being off for 1 minutes:

Pool temp: 74
Cell voltage: 26.3
Cell current: 5.90
Desired output: 100P
Instant salinity: -3100
Product name: AL-0
Software revision: r 1.59


Cell serial first 7: 3E13170
Box serial first 7: *5A0704

K-1766 kit measured salinity is 3200
 
Your volts and amps look normal.

Why are you running the cell at 100%?
 
Your volts and amps look normal.

Why are you running the cell at 100%?

It was just a test since 50% gave me inspect cell/check salt errors. I'm not planning to do 100% long term once I get things dialed in.

What is the Average salinity?

Maybe the cell is running while the pump is off with no flow?

Average is up to 3000 now that it has been running and generating for a while. I shut the pump off and confirmed "No Flow" illuminates.
 
However, I left the SWCG on overnight and it definitely generated. Will keep trying to get it dialed in and report back with any other issues. Thanks!
 
  • Like
Reactions: JamesW

Enjoying this content?

Support TFP with a donation.

Give Support