IntelliChlor SCG circuit board JP2 and JP4

The IntelliChlor Controller Circuit Board communicates to the IntelliCenter MotherBoard via an RS-485 4-conductor, 22 AWG or larger cable.
The cable connects to either JP2, JP3 or JP4 on the IntelliChlor Controller Circuit Board and connects to either of the COM PORTS on the MotherBoard. Either RS485-A (J5) OR RS485-B (J4).
Here is a diagram and which can also be found on pp 33 of your IntelliCenter Control System Installation Guide.


1707593049415.png
 
So any of the JP2, JP3 or JP4 can be connected to the motherboard Comm port J4 or J5. OK thanks. I have two wires (a green and a yellow data cable) double connected on the same connector on the intellichlor connector. Should they be moved to one of the other comm ports on the intellichlor board?
 
  • Like
Reactions: JamesW
Thread Status