Recent content by pool999

  1. P

    Pumps wont start after repair

    Took multimeter - was getting 120v at each breaker but not 240 across the two. Replaced the breaker not giving me 240v on that BUS and bingo, back in business. Thanks all
  2. P

    Pumps wont start after repair

    Bearings were shot.... Will grab my meter and check the line voltage, thanks.
  3. P

    Pumps wont start after repair

    Yep - I understand that, thanks.
  4. P

    Pumps wont start after repair

    Thanks for the quick response. Both timers are 240v. I am using a fluke voltage indicator (the type that turns red when voltage is detected). The one pole failure would make sense in that there would still be voltage from the other pole. I do have a multimeter, but did not have it with me...
  5. P

    Pumps wont start after repair

    Yesterday I replaced the motor to my booster pump, Polaris PB4-60. I have a breaker panel feeding two intermatic timers, one for the pool pump and one for the booster cleaner pump. While the pool pump was running, I just turned off the breaker feeding both of the intermatic timers. The pool...
  6. P

    Pentair Mastertemp 400 Combination Gas Control Valve Issue / Question

    Thanks for your reply @ajw22 - I was able to clean the contact and see all of those post were connected. I put the contact on the middle one and it fired right up. The pool service company wanted $400 for a new valve and $200 for labor. Seems anyone who works on this widely used heater would...
  7. P

    Pentair Mastertemp 400 Combination Gas Control Valve Issue / Question

    Hello Everyone - I discovered my heater went out and called a local company to come take a look. Turns out, I've been hosting a mice hotel in my heater and they effectively have somehow chewed on where one of the electrical connections connects to the Gas control valve (see arrow in pic). My...
  8. IMG_6712 copy.jpg

    IMG_6712 copy.jpg

  9. P

    Help Please - Numbers posted

    Thanks Caco. It's going well, looks like I'm in the clear. Losing less than 1ppm over night and water is clear as can be. Letting it drift down to normal chlorine levels now. My PH was good pre slam so should be good there. Going to need a refill on my solutions after all this testing!
  10. P

    "You don't need to worry about CYA <dude> if the water looks clear". Agree?

    Re: "You don't need to worry about CYA <dude> if the water looks clear". Agree? I can tell you from a person going through a SLAM process right now, CYA matters. I let my CYA levels get high (unknowingly), water was clear (could see the phillips head screw on the drain), tested water weekly...
  11. P

    Help Please - Numbers posted

    Just wanted to post an update and new #'s. On Saturday I replaced 50% of my water and started the SLAM process. Numbers below. My PH is high, but pool school tells me PH is inaccurate during SLAM, when should it be accurate again? I know my SLAM FC is high for my CYA (I got a little carried...
  12. P

    Help Please - Numbers posted

    Thanks Splash. I just tried the diluted method for the CYA and got 118, so it's definitely high. Also checked my FC again and it's up to 12 since I added shock and what bleach I had on hand last night(obviously not high enough for slam level). I'll wait to pump some water out then bring to...
  13. P

    Help Please - Numbers posted

    I don't have a drain
  14. P

    Help Please - Numbers posted

    Looks like I can get my hands on a pump tomorrow or Sunday. Should I go ahead and bring it to slam levels today? Then drain half tomorrow or Sunday and go from there? Or just wait and drain/refill and go from there? Also, we've had quite a bit of rain lately. Is it safe to drain half...