Thank you, sir! I do not hear a click at all in the box when turning it to auto. What cell do you recommend purchasing as a replacement that is compatible with my box?
Yes, it worked last year. I moved into the property a year ago so I do not know the age. However, I can confirm that it worked until January. I just cleaned the cell as well.
Box SN: 3A14143
Cell SN: 8885A5D
Hello,
The readings are the same when off an on auto and are as follows:
0
76
33.3
0.00
100P
-0
Al-0
R1.59
T-15
The model number is AQR15. The salinity is 3100 and was tested at leslies.
Hello,
I have a Hayward Aquarite goldline SWG that is reading 0. The salt levels are around 3,000 by a test. I do not hear a click when turning the SWG on. Is this the salt cell or main PBC?