Recent content by Atl Greg

  1. A

    IAquaLink 2.0 connection problem...connects to network but not web

    Thanks Mark, Had the same issue, Logged out of the app, then back in. Issue solved. Seems the upgrade caused the problem Jandy wanted me to re-link the system to my router.
  2. A

    Jandy AquaLink / iLink

    Thanks, for the video. Looks like i need to reseat the 2 4 wire (red connectors) i will try that. Here are pics of what i am dealing with
  3. IMG_2765.jpg

    IMG_2765.jpg

  4. IMG_2764.jpg

    IMG_2764.jpg

  5. IMG_2767.jpg

    IMG_2767.jpg

  6. A

    Jandy AquaLink / iLink

    Have done multiple reboots no luck. Do you have a pic of the specific cable you are referencing Thank you
  7. A

    Jandy AquaLink / iLink

    Hi PoolGate. I have the old black handheld 3.0 Firmware Rev T.2 J-Box 3.0. With the Aqualink upgrade I do have smart-phone and computer interfaces. I can not see a salinity or aquapure setting on my iPhone, handheld or on the web interface
  8. IMG_2760.jpg

    IMG_2760.jpg

  9. IMG_2762.jpg

    IMG_2762.jpg

  10. IMG_2757.jpg

    IMG_2757.jpg

  11. i Link screenshot.jpg

    i Link screenshot.jpg

  12. A

    Jandy AquaLink / iLink

    My Aqualink (2007) does not show Salinity or the AquaPure setting on my handheld or my iLink (upgraded to Aqualink in 2021) The only readings that show on the handheld or on iLink is the pump speed, watts, Air & Water temperature I can get the Salinity & AquaPure setting readings on the AquaLink...
  13. Aquapure AKC-13 front PCB.jpg

    Aquapure AKC-13 front PCB.jpg

  14. A

    Replacement for obsolete Zodiac R0403900 Front LED Printed Circuit Board

    RamseyPool, Did you have any luck getting your board repaired? Or is there a replacement / upgrade for the old R0403900
  15. A

    Old Skimmer Lines now Leaking