Hello everyone, thank you for taking the time to read.
I have a customer with an IntelliCenter with the I8PS daughter card. On his deck are 2 IS4 SPA side remotes.
Remote 1 controls SPA lights, waterfall, deck jets and lazy river
This remote is wired to the main board
Remote 2 controls Pool lights, Slide, Jacuzzi and lazy river fast action
This remote is wired to the I8PS daughter card
I showed up one day and the entire remote 2 stopped working. I swapped the 2 remote to test if the buttons were working and the remote 2 tested ok. Got on the phone with Pentair, they had me run the same tests, and concluded the daughter card is bad.
I took the daughter card to a computer repair shop who found a fault on capacitor C26, he replaced C26 and do not have a fault on anything else after. I reinstalled the board but still having the same issue.
Is there anything else I could do before replacing this $1300 card that’s only 14 months old?
I have a customer with an IntelliCenter with the I8PS daughter card. On his deck are 2 IS4 SPA side remotes.
Remote 1 controls SPA lights, waterfall, deck jets and lazy river
This remote is wired to the main board
Remote 2 controls Pool lights, Slide, Jacuzzi and lazy river fast action
This remote is wired to the I8PS daughter card
I showed up one day and the entire remote 2 stopped working. I swapped the 2 remote to test if the buttons were working and the remote 2 tested ok. Got on the phone with Pentair, they had me run the same tests, and concluded the daughter card is bad.
I took the daughter card to a computer repair shop who found a fault on capacitor C26, he replaced C26 and do not have a fault on anything else after. I reinstalled the board but still having the same issue.
Is there anything else I could do before replacing this $1300 card that’s only 14 months old?