Difference between revisions of "Pentair Intellichlor ICXX SWG" - Further Reading

Line 1: Line 1:
==Cell Usage==
+
=How to Determine the Intellichlor Cell Usage=
 
Pressing and holding the “More” button launches the System Status Mode. When the lights finish scrolling, the percent lights indicate hours of usage in 1,000s. For example, if the 40% light lights, that indicates 4,000 hours.
 
Pressing and holding the “More” button launches the System Status Mode. When the lights finish scrolling, the percent lights indicate hours of usage in 1,000s. For example, if the 40% light lights, that indicates 4,000 hours.
  
==Flow/Temperature Switch==
+
=What Does the Flow/Temperature Switch do on the Intellichlor?=
  
 
The flow switch also contains a thermistor that senses water temperature.  The water temperature is used for the salinity calculation.  If the thermistor is failing the salinity will be incorrect.
 
The flow switch also contains a thermistor that senses water temperature.  The water temperature is used for the salinity calculation.  If the thermistor is failing the salinity will be incorrect.
Line 16: Line 16:
 
A suspected bad flow switch can be confirmed by cutting the black and red wires and connecting them together coming out of the cell.  If the cell operates with the wires connected this confirms the flow switch was bad.  Do this only for temporary diagnostic purposes.
 
A suspected bad flow switch can be confirmed by cutting the black and red wires and connecting them together coming out of the cell.  If the cell operates with the wires connected this confirms the flow switch was bad.  Do this only for temporary diagnostic purposes.
  
===High Salt===
+
==What Causes the High Salt Light on the Intellichlor?==
  
 
High salt error occurs around 4500ppm.  The cell will continue generating chlorine with a high salt warning.
 
High salt error occurs around 4500ppm.  The cell will continue generating chlorine with a high salt warning.
  
===Low or High Salt Lights===
+
==What Does the Intellichlor Low or High Salt Lights Mean?==
  
 
Always check salt level independent of the cell before adding salt.  A failure of the temperature sensor will give incorrect salt warnings.
 
Always check salt level independent of the cell before adding salt.  A failure of the temperature sensor will give incorrect salt warnings.
  
===Cold Temperature===
+
==What Does the Intellichlor Do in Cold Temperature?==
 
The cell will stop generating chlorine when water temperate is below 60 degrees.
 
The cell will stop generating chlorine when water temperate is below 60 degrees.
  
 
If the cell light says cold when the water is warm, the temperature sensor is likely bad.
 
If the cell light says cold when the water is warm, the temperature sensor is likely bad.
  
===Displaying Cell Water Temperature===
+
==How Do You Display Intellichlor Cell Water Temperature?==
 
Version 3.1 on adds the ability to determine system temperature. Pressing the “More” button after the display shows 1,000s of hours of usage, will show temperature as follows:<ref>https://www.troublefreepool.com/threads/intellichlor-system-status-mode.134913/</ref>
 
Version 3.1 on adds the ability to determine system temperature. Pressing the “More” button after the display shows 1,000s of hours of usage, will show temperature as follows:<ref>https://www.troublefreepool.com/threads/intellichlor-system-status-mode.134913/</ref>
  
Line 59: Line 59:
 
Press and hold the More button until the lights scroll and note which % light lights up. Then, immediately press the More button again and see which % lights light up.
 
Press and hold the More button until the lights scroll and note which % light lights up. Then, immediately press the More button again and see which % lights light up.
  
==Salinity Calculation==
+
=How Does the Intellichlor Calculate Salinity?=
 
The salinity is calculated based on the conductivity of the water and the water temperature.
 
The salinity is calculated based on the conductivity of the water and the water temperature.
  
Line 66: Line 66:
 
The Intellichlor manual states that measurements will vary between measuring devices (salt test strips, electronic testers, andtitration). The salt sensor reading is within +/- 500 ppm accuracy.<ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
 
The Intellichlor manual states that measurements will vary between measuring devices (salt test strips, electronic testers, andtitration). The salt sensor reading is within +/- 500 ppm accuracy.<ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
  
==Salt Levels==
+
=What is the Recommended Intellichlor Salt Level?=
 
*3600 ppm of salt is recommended for optimum water condition.<ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
 
*3600 ppm of salt is recommended for optimum water condition.<ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
 
*Low salt concentration below 2600 ppm will cause the unit to turn off
 
*Low salt concentration below 2600 ppm will cause the unit to turn off
Line 72: Line 72:
 
*The cell tests the salt level every 12 hours.  So it may take 12 hours for the salt level on the cell to change after adding salt.
 
*The cell tests the salt level every 12 hours.  So it may take 12 hours for the salt level on the cell to change after adding salt.
  
==Cycle Time==
+
=What is the Intellichlor Cycle Time?=
 
The Intellichlor cycles the % generation in 5 minute intervals.  If the % generation is set to 50% the cell will generate chlorine for 2.5 minutes and be idle for 2.5 minutes.
 
The Intellichlor cycles the % generation in 5 minute intervals.  If the % generation is set to 50% the cell will generate chlorine for 2.5 minutes and be idle for 2.5 minutes.
  
==ET/ScreenLogic reports Salt Level as Zero==
+
=What to Do If Easy Touch/ScreenLogic Reports Salt Level as Zero=
 
For some reason, unknown to Pentair, minor changes to the system will cause the salt level in the EasyTouch and ScreenLogic to read zero.<ref>https://www.troublefreepool.com/threads/screenlogic-reports-salt-level-as-zero.180867/#post-1598882</ref>  This is just an error in reporting and the cell should still be working as long as the actual salt level is ok and the cell does not show a "red low salt" light on the cell. I believe that there is a timing issue in the circuitry that reports the salt reading to the EasyTouch. It is obvious that the cell knows what the real salt level is. This has been "Fixed" by the following actions:
 
For some reason, unknown to Pentair, minor changes to the system will cause the salt level in the EasyTouch and ScreenLogic to read zero.<ref>https://www.troublefreepool.com/threads/screenlogic-reports-salt-level-as-zero.180867/#post-1598882</ref>  This is just an error in reporting and the cell should still be working as long as the actual salt level is ok and the cell does not show a "red low salt" light on the cell. I believe that there is a timing issue in the circuitry that reports the salt reading to the EasyTouch. It is obvious that the cell knows what the real salt level is. This has been "Fixed" by the following actions:
  
Line 84: Line 84:
 
*Replacing the salt cell itself.
 
*Replacing the salt cell itself.
  
==Power Center==
+
=What Does the Intellichlor Power Center Do?=
  
 
The ICXX cells are powered by either a stand-alone Power Center box or a transformer that is integrated with an Easy Touch or Intellicenter Load Center.
 
The ICXX cells are powered by either a stand-alone Power Center box or a transformer that is integrated with an Easy Touch or Intellicenter Load Center.
  
===Power Center Wiring===
+
==How is the Intellichlor Power Center Wired?==
 
The stand-alone Power Center box can run with 120V or 240V ac power.  You have to wire the transformer for 240 volts or 120 volts.
 
The stand-alone Power Center box can run with 120V or 240V ac power.  You have to wire the transformer for 240 volts or 120 volts.
  
Line 95: Line 95:
 
When using the 120 volts, you connect the hot wire to the Yellow and Black wires and the Neutral to the Blue/Violet and White wires.
 
When using the 120 volts, you connect the hot wire to the Yellow and Black wires and the Neutral to the Blue/Violet and White wires.
  
==Cell Should Not be Powered When Pump is Off==
+
=Intellichlor Cell Should Not be Powered When Pump is Off=
  
 
The flow switch is a secondary safety mechanism. There should be a primary means for the cell not to be powered when the pump is off and there is no water flow.  This can be with pool automation equipment or a mechanical timer.
 
The flow switch is a secondary safety mechanism. There should be a primary means for the cell not to be powered when the pump is off and there is no water flow.  This can be with pool automation equipment or a mechanical timer.
Line 107: Line 107:
 
''WARNING:CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING:  To reduce the risk of personal injury the IntelliChlor® Salt Chlorine Generator (SCG) Power Center must be installed on and wirded to the load side of the time clock, electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. Otherwise, dangerous chlorine gas buildup can occur. The IECG should never be energized when the pool pump is OFF and water is not flowing through the unit.'' <ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
 
''WARNING:CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING:  To reduce the risk of personal injury the IntelliChlor® Salt Chlorine Generator (SCG) Power Center must be installed on and wirded to the load side of the time clock, electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. Otherwise, dangerous chlorine gas buildup can occur. The IECG should never be energized when the pool pump is OFF and water is not flowing through the unit.'' <ref>https://www.pentair.com/content/dam/extranet/product-related/product-manuals/pool-and-spa-equipment/intellichlor/IntelliChlor_Owners_Manual_Version_3_units_after_Nov_2011_English.pdf</ref>
  
===Cell Explosions do Happen===
+
==Intellichlor Cell Explosions do Happen==
 
Here is one report - [https://www.troublefreepool.com/threads/explosion-near-the-swg.183280/ Explosion near the SWG]
 
Here is one report - [https://www.troublefreepool.com/threads/explosion-near-the-swg.183280/ Explosion near the SWG]

Revision as of 21:36, 31 August 2019

How to Determine the Intellichlor Cell Usage

Pressing and holding the “More” button launches the System Status Mode. When the lights finish scrolling, the percent lights indicate hours of usage in 1,000s. For example, if the 40% light lights, that indicates 4,000 hours.

What Does the Flow/Temperature Switch do on the Intellichlor?

The flow switch also contains a thermistor that senses water temperature. The water temperature is used for the salinity calculation. If the thermistor is failing the salinity will be incorrect.

Flow switch has 4 wires:

  • Red/black - flow switch
  • Green/white - temperature sensor

The IntelliChlor uses the Harwil Q-12DST-C2 flow switch.[1] It has an integrated 10k thermistor.[2]

With no temperature input, the cell defaults to a temperature of 77 Fahrenheit. The sensors are prone to failure. When the sensor fails and it's obvious to the software that the sensor has failed, it defaults to a standard temperature of 77 f.

A suspected bad flow switch can be confirmed by cutting the black and red wires and connecting them together coming out of the cell. If the cell operates with the wires connected this confirms the flow switch was bad. Do this only for temporary diagnostic purposes.

What Causes the High Salt Light on the Intellichlor?

High salt error occurs around 4500ppm. The cell will continue generating chlorine with a high salt warning.

What Does the Intellichlor Low or High Salt Lights Mean?

Always check salt level independent of the cell before adding salt. A failure of the temperature sensor will give incorrect salt warnings.

What Does the Intellichlor Do in Cold Temperature?

The cell will stop generating chlorine when water temperate is below 60 degrees.

If the cell light says cold when the water is warm, the temperature sensor is likely bad.

How Do You Display Intellichlor Cell Water Temperature?

Version 3.1 on adds the ability to determine system temperature. Pressing the “More” button after the display shows 1,000s of hours of usage, will show temperature as follows:[3]


Lights Temperature
No LEDs Below 30F
40% 36 to 45F
40% and 60% 46 to 55F
60% 56 to 65F
60% and 80% 66 to 75F
80% 76 to 85F
80 and 100% 86 to 95F
100% 96 to 99F
100% blinking over 99F
All LEDs blinking Sensor bad

Press and hold the More button until the lights scroll and note which % light lights up. Then, immediately press the More button again and see which % lights light up.

How Does the Intellichlor Calculate Salinity?

The salinity is calculated based on the conductivity of the water and the water temperature.

The conductivity sensor is a separate device in the cell which can be seen if you look in the cell.[4]

The Intellichlor manual states that measurements will vary between measuring devices (salt test strips, electronic testers, andtitration). The salt sensor reading is within +/- 500 ppm accuracy.[5]

What is the Recommended Intellichlor Salt Level?

  • 3600 ppm of salt is recommended for optimum water condition.[6]
  • Low salt concentration below 2600 ppm will cause the unit to turn off
  • High salt concentration above 4500 ppm may cause excessive corrosion or deterioration to pool equipment and surrounding surfaces in and around the pool.
  • The cell tests the salt level every 12 hours. So it may take 12 hours for the salt level on the cell to change after adding salt.

What is the Intellichlor Cycle Time?

The Intellichlor cycles the % generation in 5 minute intervals. If the % generation is set to 50% the cell will generate chlorine for 2.5 minutes and be idle for 2.5 minutes.

What to Do If Easy Touch/ScreenLogic Reports Salt Level as Zero

For some reason, unknown to Pentair, minor changes to the system will cause the salt level in the EasyTouch and ScreenLogic to read zero.[7] This is just an error in reporting and the cell should still be working as long as the actual salt level is ok and the cell does not show a "red low salt" light on the cell. I believe that there is a timing issue in the circuitry that reports the salt reading to the EasyTouch. It is obvious that the cell knows what the real salt level is. This has been "Fixed" by the following actions:

  • Just shutting off and rebooting the ET
  • Replacing the flow switch
  • Replacing the ET's surge card (power supply for the cell)
  • Replacing the ET's main board
  • Replacing the salt cell itself.

What Does the Intellichlor Power Center Do?

The ICXX cells are powered by either a stand-alone Power Center box or a transformer that is integrated with an Easy Touch or Intellicenter Load Center.

How is the Intellichlor Power Center Wired?

The stand-alone Power Center box can run with 120V or 240V ac power. You have to wire the transformer for 240 volts or 120 volts.

When using 240 volts (often called 220) you connect L1 to the Yellow wire and L2 to the White wire and connect the Blue/Violet to the Black wire with a wire nut.

When using the 120 volts, you connect the hot wire to the Yellow and Black wires and the Neutral to the Blue/Violet and White wires.

Intellichlor Cell Should Not be Powered When Pump is Off

The flow switch is a secondary safety mechanism. There should be a primary means for the cell not to be powered when the pump is off and there is no water flow. This can be with pool automation equipment or a mechanical timer.

Pentair Manuals say:

The IntelliChlor Salt Chlorinator Power Centers must be interconnected with the pool pump motor power source. This ensures the IntelliChlor Salt Chlorinator and pool pump will switch on and off together. [8]

and

WARNING:CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING: To reduce the risk of personal injury the IntelliChlor® Salt Chlorine Generator (SCG) Power Center must be installed on and wirded to the load side of the time clock, electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. Otherwise, dangerous chlorine gas buildup can occur. The IECG should never be energized when the pool pump is OFF and water is not flowing through the unit. [9]

Intellichlor Cell Explosions do Happen

Here is one report - Explosion near the SWG