  1. mikespoolfl

    Is poolsupplyworld.com legit?

    I just got a pentair VS pump from them a couple of months ago. Happy with the price and the service. BlakeJ keeps a eye on the board and will jump in if he sees a problem. Glad everything work out for you.
  2. mikespoolfl

    Hayward SP3400VSP technical question

    I have the Intermatic Surge Protector PS3000, it's a panel protector. Replaced the old no name one when I replaced my hayward ecostar with the bad drive.
  3. mikespoolfl

    Hayward Ecostar VSP pump stalled

    I have one on the main panel for the house and one one the sub panel for the pool. - - - Updated - - - Forgot about the one on the meter. The software seemed to work ok from what I could see on the display. I also checked the impendence on the motor leads and they were either .6 or .7 ohms and...
  4. mikespoolfl

    Hayward Ecostar VSP pump stalled

    I took the drive apart enough to see what was under the burn. It appeared to be a surface mount resistor.
  5. mikespoolfl

    Hayward Ecostar VSP pump stalled

    I'm going to replace the pump. Haven't decided with what yet. I've been looking at Pentair intellflo.
  6. mikespoolfl

    Hayward Ecostar VSP pump stalled

    Sounds like my ecostar that died about a month ago. From what I could determine from the trouble shooting that Hayward recommends it’s the drive unit that died. I’ve seen a few photos of some units that have had drive unit die and I have noticed a little burn spot right above the circle next...
  7. mikespoolfl

    Need to start planning on new pump for spring

    If you are looking at the intelliflo VS model 011018. You may want to look at it's replacement coming out the intelliflo 2 VST model # 011055.
  8. mikespoolfl

    New wet end for the intelliflo ?

    Looks like this is going to be the new intelliflo to replace model 011018. New model number is 011055 and is called the intelliflo 2 VST. You can go to energystar.gov website and compare the 2 models. Looks like a more efficient wet end. A few other bells and whistles about it on Pentair site...
  9. mikespoolfl

    Need Help - EcoStar SP3400VSP - Have read tons of threads.... Still need help.

    I have the Ecostar with a cartridge filter. One configuration I have noticed for my setup is if the filter is dirty and I divert the water through the heater it sometimes has a problem priming. This only happens if diverted to heater. Dirty filter any other time has little or no effect on...
  10. mikespoolfl

    Variable speed pumps and air in basket at low speed

    I have the hayward ecostar and usually the pump will try and reprime itself if it starts sucking air.
  11. mikespoolfl

    Hayward Eco Star Questions

    What about making a 2” manifold for the intake being feed by all the 1 ½ intakes placing upgraded valves on the 1 ½ pipes . And using 2 “ for the pad plumbing. Make a 2” return manifold run all the returns off that. Placing upgraded valves on the return lines not on the manifolds.
  12. mikespoolfl

    Long sweep 90° pressure fittings???

    I've used those on the intake side for a few years and have not had any problems. I have gotten sch 40 sweep fittings here flexpvc.com . and use those on the pressure side. Look under PVC-Elbows-90-Sweeps
  13. mikespoolfl

    need a recommendation on a new variable speed pump

    I have the Ecostar. With all the timers ( 8 separate) you can run it 800 to a 1000 rpm just to filter, and have it speed up a couple of times a day to make the skimmer work more effectively. I also have a fountain and a spa. So it also allows me to tweak the speed for optimal use of anything...
  14. mikespoolfl

    Hayward Ecostar Pump Freeze Protection Setting

    Your menu should have Timers- Speed- Diagnostic- Configuration Press menu till you get to configuration menu. It should say locked. Push and hold down < > at the same time till it says unlocked. Press > nine times and you will get to where you can enable freeze settings. Press > again and you...
  15. mikespoolfl

    Hayward Ecostar Pump Freeze Protection Setting

    Re: Hayward Ecostar Pump I don’t remember where I read about the freeze protection either. When I got the pump and read the manual there is no mention of the freeze protection and I just stumbled across it just playing around with the settings. Glad to help. This forum has helped me so much...
  16. mikespoolfl

    Hayward Ecostar Pump Freeze Protection Setting

    Re: Hayward Ecostar Pump Press menu, press and hold < > and it will unlock configuration menu. Press > till you get to “low temp operation” it takes more than 7 presses to get to it. There you can enable or disable. I think the next press will get to the speed it will run at. Press again and...
  17. mikespoolfl

    Intelliflo Weather Resistance??

    Below is from Pentair VS 3050 manual page 18 3. Protect against moisture: • Protect from splashing pool water. • Protect from the weather. • Protect from lawn sprinklers. • If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has been flooded...
  18. mikespoolfl

    in ground pool with spa need help

    Your pool configuration sounds a lot like mine. I had a 1.5 hp pump and had to open the valves to spa and close all the returns to the pool and get the pressure up a little over 25 psi to get the jets to have bubbles in them. At 20 psi it could not pull the air in. My spa has 4 jets and 1.5...
  19. mikespoolfl

    How Small is too Small?

    Most spa's need quite a bit of water moving fast. You may not get bubbles in the jets with 1 hp.
  20. mikespoolfl

    upgrading to a new pump

    How long are you run times? I was typing the same things :lol:
  21. mikespoolfl

    How much wattage per hr does a Hayward Super 2 pump use?

    I agree with Jason I've seen my house voltage anywhere from 108 to 124 volts. Then add in power factor and there could be a difference. I guess were are looking at a snapshot when what is happening is a movie.
  22. mikespoolfl

    How much wattage per hr does a Hayward Super 2 pump use?

    All the following reading where taken with a clamp amp meter. I had a single speed 1.5 hp pump that drew 18.6 amps. I replaced it with the EcoStar about 2 weeks ago. Running the the Ecostar at 2500 rpm gives close to the old pump flow ( I can tell by the pressure at a fountain) it draws 6...
  23. mikespoolfl

    Skimmer Lines

    Jason would 90 psi be getting a little high?
  24. mikespoolfl

    old pump and estimation of the turnover time

    Since intake is 1.5 inch that’s going to be the max you will be able to flow. Most agree that 44 gallons minute is about the max you will get though that. So in theory all things perfect you would need at least 11 hours for your pool for one turn over. In reality I would think 14 or more...
  25. mikespoolfl

    Goodbye VS-3050...

    I just ordered ecostar for $906 delivered. Tracking number says I should have it Weds.
  26. mikespoolfl

    Would like to add new return line to gunite IG spa

    Another work around would be to leave one of the eyes loose enough so you can just reach in and take one out. This will reduce back pressure and keep the venturi effect from happening. Just screw it back in when you get in.
  27. mikespoolfl

    Suction manifold redo

    Bad lableing, they should be pool drain and spa drain. Between pool drain and skimmer will be new take off for pump. I found a good price on these "Pentair 1.5" PVC, 2-Way Lube-Free Diverter Valve, with 2" Slip Outside" $22.76. If order is over $149 free shipping.