Search results

  1. M

    Pool heater nightmare 400K BTU Pentair/ Sta rite heater

    Thanks everyone for the help. Problem fixed. Paul (ps0303) was correct. It ended up being a flow issue which can be tricky to diagnose unless you know a little bit about what you're doing. Gas company technician came, replaced new gas meter, and announced it had to be my gas line running from...
  2. M

    Pool heater nightmare 400K BTU Pentair/ Sta rite heater

    I understand. My hookup is meter, then gas regulator, and then it splits to the house and second run to the pool heater (2", about 100 feet).
  3. M

    Pool heater nightmare 400K BTU Pentair/ Sta rite heater

    I'm not 100% sure but i think so.
  4. M

    Pool heater nightmare 400K BTU Pentair/ Sta rite heater

    My run from the gas regulator to my heater is 2" (about 100 ft) and the last 5-8 feet is 1" I think (same caliber as the pipe that goes into and out of the gas valve).
  5. M

    Pool heater nightmare 400K BTU Pentair/ Sta rite heater

    I'm caught up in a nightmare of a situation with pool heater technician pointing at gas line issue and gas company pointing finger at pool heater. I had a StaRite Max E therm 400K btu heater which stopped working around the time my gas meter got upgraded to 2.5 psi 800 cfh. My pool technician...