Search results

  1. C

    Pump Replacement

    I verified there is 240V running to the pool equipment. I read 240V inputting to the timer and exiting the timer. The input to the safety switch also read 240V but the output was only 2.3V. So the safety switch is the culprit! Once I replace that I should be in business. Will report back once...
  2. 0C2DB400-ED4C-4533-83DE-2D33F2B4D6B3.jpeg

    0C2DB400-ED4C-4533-83DE-2D33F2B4D6B3.jpeg

  3. 437FE81B-828E-4999-BE17-4E46E37E7B15.jpeg

    437FE81B-828E-4999-BE17-4E46E37E7B15.jpeg

  4. C

    Pump Replacement

    It reads 124V
  5. 9770682E-FBCD-493C-A7E6-3027490BA7AE.jpeg

    9770682E-FBCD-493C-A7E6-3027490BA7AE.jpeg

  6. C

    Pump Replacement

    Voltage came back at 231V which should be right on the money. The nameplate gives a 208-230V range.
  7. 0739BF1B-7993-49D8-B104-4B19DBF92252.jpeg

    0739BF1B-7993-49D8-B104-4B19DBF92252.jpeg

  8. 70BF1A8D-2686-47E0-9F03-FF28AF55506A.jpeg

    70BF1A8D-2686-47E0-9F03-FF28AF55506A.jpeg

  9. C

    Pump Replacement

    Thanks for the insight. I’ll get one of those tomorrow and report back the results!
  10. 45372E10-351C-42EB-9D54-C5C40C433E3B.jpeg

    45372E10-351C-42EB-9D54-C5C40C433E3B.jpeg

  11. 4E75FCA2-E1C9-4106-B8BD-AA5C0A15C467.jpeg

    4E75FCA2-E1C9-4106-B8BD-AA5C0A15C467.jpeg

  12. FDFF0FD4-66B9-4C10-A378-ADF94ECD3C20.jpeg

    FDFF0FD4-66B9-4C10-A378-ADF94ECD3C20.jpeg

  13. C

    Pump Replacement

    Hi all, we recently left our pump (Hayward Super Pump) running over the weekend and came home to it not running. I tried everything I could think of: testing power with voltage tester all the way to the motor hookups, checking for debris/obstructions, there was no humming whatsoever so I did not...