Search results

  1. M

    Low filter pressure on two return lines (5psi) and regular filter pressure on side outlet (20psi)

    I put in the eyeballs, and the water is coming out of the returns just fine now. However, the psi at the filter pressure remains ~6 psi. I guess that is my normal 'clean' psi starting point. Thanks for your help! -Mcflied
  2. M

    Low filter pressure on two return lines (5psi) and regular filter pressure on side outlet (20psi)

    Hi Jim, So you mentioned pool return eyeballs. I don't have any on there which finally explains the low pressure. I found another return for a total of three lines. So 3 lines at 1.5" each = 4.5". With the eyeballs in place, it would be 2.25" in total (.75" x 3). This pool was resurfaced...
  3. M

    Low filter pressure on two return lines (5psi) and regular filter pressure on side outlet (20psi)

    Hi Jim. Yes that makes sense. I guess my main concern is that the flow of water coming out of the return is not great. One of the two lines barely anything coming out. The other one, the flow seems to be weak. So when switch Jandy to return, the pool water is not filtering the water at a...
  4. M

    Low filter pressure on two return lines (5psi) and regular filter pressure on side outlet (20psi)

    Hello there. I have a pool now, new to me, that I have started to clean and take care of. After taking the cartridges out and hosing them clean, I reassembled the unit and all seems to be good, except I noticed one thing. Low filter pressure when Jandy valve is switched to the two return...