  1. C

    IC60 & IntelliPH

    @Dirk thank you so much for the detailed response. I will try to keep the old one but I don't think mine can be repaired since it's not just the connector but also D3, D4 and the one next to that who got fried. First I need to get a new one LOL Pentair wants to come out to check that it's not my...
  2. C

    IC60 & IntelliPH

    I know this is an old thread but thought it's probably not worth creating a new one for my question. My IntellipH just died and Pentair is hopefully replacing it. For the new unit I would apply fix #3 but was wondering which wire size is recommended to go around the connector? Also I noticed...
  3. IMG_5677.jpeg

    IMG_5677.jpeg

  4. C

    Filter draining through solar valve

    This is the same for me but I can see the air bubbling through the pipe. (I placed a check valve in the wrong place - removed the flapper - that's how I can see into that pipe) I inspected my check valve and they seem fine - the pump is not draining just the filter. Next step is to disassemble...
  5. C

    Filter draining through solar valve

    yes ideally it would be after the filter but I didn't have enough space to put it after the filter but before the solar stub.
  6. C

    Intellicenter freeze protection heater bypass valve

    That is a very good point. I will run some tests to find the optimum and report back.
  7. C

    Intellicenter freeze protection heater bypass valve

    as soon as I want to protect the heater from my water chemistry I need to close the loop completely which then doesn't provide freeze protection. Sorry I am a bit confused.
  8. C

    Intellicenter freeze protection heater bypass valve

    Originally I had it at the green line and closed the heater completely. As soon as I open it a bit for the heater to get some water flow I also close the bypass loop a bit and I wasn't sure what the optimum setting there is. Don't I get the efficiency benefits if both heater and bypass are...
  9. C

    Intellicenter freeze protection heater bypass valve

    Yes now that I changed it but now I am not sure if that's what Pentair had in mind for the bypass loop.
  10. C

    Intellicenter freeze protection heater bypass valve

    Yes correct. (That wasn't the case until today when I changed it) I am still trying to understand how Pentair set it up in their manual (which doesn't work for me since my plumbing is different).
  11. C

    Filter draining through solar valve

    As long as the drained filter is not a concern everything is good I guess :) Thank you!
  12. C

    Intellicenter freeze protection heater bypass valve

    A bit hard to show there is not a lot of space behind the heater.
  13. C

    Filter draining through solar valve

    It's a true solar valve with the little check valve on it.
  14. C

    Filter draining through solar valve

    Today I noticed that after the pump turned off my filter drained by getting air through the solar valve. I have a check valve between the pump and filter so the pump did not drain. Is this something I should be concerned about? Below is my plumbing setup.
  15. Screenshot 2023-12-04 at 4.46.03 PM.png

    Screenshot 2023-12-04 at 4.46.03 PM.png

  16. C

    Intellicenter freeze protection heater bypass valve

    @ajw22 Thank you so much for the attachment. I had not set it up that way 🤦‍♂️My plumbing is a bit different than in their manual I hope the following setup also makes sense?
  17. C

    Intellicenter freeze protection heater bypass valve

    Now that it's getting colder I thought it would be a good idea to setup the intellicenter freeze protection circuits. So far it seemed very straight forward with the exception of my heater bypass valve. What do I need to do for the heater valve to open when freeze protection is active so that...
  18. C

    IntelliFloXF VSF RPM vs GPM

    I am still curious to understand why there is such a big difference between the pump GPM and the FlowValve reading o_O
  19. C

    IntelliFloXF VSF RPM vs GPM

    I guess I’m cleaning it too much then 3 times a year 😆 I haven’t had solar long enough to actually get the filter dirty.
  20. C

    IntelliFloXF VSF RPM vs GPM

    I want my solar system to run at 50GPM independent of how dirty/ clean the filter is so I thought setting it a certain GPM would make my life easier but it seems like I should just stick to RPM and call it a day :D
  21. C

    IntelliCenter 2.017 FW Update

    Maybe it's related to my IntelliFloXF VSF pump. (FW 2.11)
  22. C

    IntelliFloXF VSF RPM vs GPM

    I was wondering if using GPM or RPM is better when setting different programs in the intellicenter. I assume GPM is better in theory since it adjusts based on filter resistance and other things but I wasn't sure if it's actually that smart/ good. Also I noticed that the set GPM in the pump is...
  23. Screenshot 2023-07-14 at 5.46.31 PM.png

    Screenshot 2023-07-14 at 5.46.31 PM.png

  24. C

    IntelliCenter 2.017 FW Update

    I had the pentair repair guys come out a couple of times and it seems like their is a bug in the FW related to the solar circuit.
  25. C

    IntelliCenter 2.017 FW Update

    I tried that and a few other things with Pentair which didn't help. Good thing downgrading is very easy and the update didn't add any new functionality. So I am back at the previous version and everything works great again.
  26. C

    IntelliCenter 2.017 FW Update

    Thank you for the super quick reply. I have 022056 VS pumps. The display showed not active. The FW is 2.11 does that mean my pumps are running super old FWs? Interestingly my spa jet pump and water feature pump work as expected just the main circulation pump does not.
  27. C

    IntelliCenter 2.017 FW Update

    I just updated to 2.017 yesterday evening and this morning my circulation pump started as specified in the schedule but when solar kicks in and the valve opened it didn't increase its RPM as it usually does. When I turn off the pump the dot in the app shows the pump as off by turning red but the...
  28. C

    Heater not turning on

    Thanks for all the comments. @JJ_Tex is there anyway to see if the heater is available on the little display at the intellicenter? I didn't have time to setup wifi/ lan connection yet.
  29. C

    Heater not turning on

    The pool has been filled for 2 weeks now so too early to turn on the heater (pentair mastertemp 400) but I wanted to see if it at least works (has power). And apparently it doesn’t - no light or anything on the display. Pumps, intellivalves and intellicenter work. Is there anything I need to do...
  30. C

    Intellivalve multiple stop points

    Are their any plans to implement that at some point? If the default position for the valve is bubbler off and I want to feature circuits with the bubbler on: 1) low flow and 2) max flow how would I achieve that? I can only assign the valve to open the bubbler to one circuits is my understanding.