Search results

  1. TDockUSC

    Calcium in T-Cell?

    Understood...I guess I'm just struggling to figure out what changed. I've had this pool for 3 summers, this spring we re-plastered and now the massive and rapid scaling. It feels like they have to be related, to me, but maybe not.
  2. TDockUSC

    Calcium in T-Cell?

    Will do on lowering TA. With my current levels over the last two weeks, does it seem probable that the amount of scaling occurred as seen in the pics?
  3. TDockUSC

    Calcium in T-Cell?

    Correct, which is why I am so confused. I added 25lbs of of calcium chloride on June 15 in an effort to raise my CSI slightly because I'd read here that can help slow the pH rise in new plaster pools. I added it the way I've always done, in the deep end and then brushed. I took a closer pic of...
  4. IMG_4833.jpeg

    IMG_4833.jpeg

  5. TDockUSC

    Calcium in T-Cell?

    Hey guys, I am having an issue with calcium build up (I think) in my t-cell. Before I get to that, some quick info: I had my entire pool replastered this spring. My PB did a 30-day acid treatment to start up and handed it over to me in June. Since then I've brushed, maintained pH as best I can...
  6. IMG_4831.jpeg

    IMG_4831.jpeg

  7. IMG_4832.jpeg

    IMG_4832.jpeg

  8. TDockUSC

    Jack’s Magic Power Blue Scale Off question

    SLAM update: Even more convinced the Jack’s is messing with something… My pool is fairly shaded…tested at 7:16pm last night and FC held at 24 from a 6pm addition of chlorine. Pool was losing plenty of FC while sunny, drop stopped once sun was off the pool. At 8:30pm FC still at 24 (so I was...
  9. TDockUSC

    Jack’s Magic Power Blue Scale Off question

    Thanks so much! In the meantime, I've started a SLAM just to be safe...here are my updated numbers from this morning, pre-SLAM (some of the numbers last night were a few weeks old so I retested everything this morning): FC-8 CC-0 PH-7.4 TA-70 CH-350 CYA-60 Salt—3000
  10. TDockUSC

    Jack’s Magic Power Blue Scale Off question

    Hi all, I recently used about a quart of Jack’s Magic Power Blue Scale Off to remove scale from my pool tiles (it worked well.) Since then, I’ve noticed either a massive increase in FC demand or it’s affecting the tests. I’ve seen that other Jack’s Magic products can cause issues with FC...
  11. TDockUSC

    Hayward TCell940 Daily Output?

    Quick question, just had a TCell940 added to my system. I'm trying to configure pool math and I am gettin conflicting info so I wanted to verify here. What is the daily chlorine output? Some places say 1.47 lbs per day while others say it's 1.74 lbs per day. Thanks!
  12. TDockUSC

    New Pool, New Questions

    The only acid I have on hand is muriatic acid. Would that work?
  13. IMG_3936.jpeg

    IMG_3936.jpeg

  14. IMG_3935.jpeg

    IMG_3935.jpeg

  15. TDockUSC

    New Pool, New Questions

    Hey guys, I found the site two years ago when I added a fiberglass pool to my home. You were and continue to be an amazing resource. I recently sold that home and bought an older home with a much larger, older pool. I'm pretty sure the pool is about 20 years old, gunite and about 31,000...
  16. IMG_3937.jpeg

    IMG_3937.jpeg

  17. TDockUSC

    Delete Heyward Online Owner Account?

    I reached out to Heyward directly and they said the new owner would have to contact them to get the account transferred.
  18. TDockUSC

    Delete Heyward Online Owner Account?

    Hey guys, I am in the process of moving. I currently have the Goldline Aqua Connect network module on my pool and I am trying to figure out to either transfer it to the new owner or simply delete my account so he can set his own info up tomorrow. I've searched the manuals and online and I've...
  19. TDockUSC

    FC in low-circulation areas

    Makes sense. Do I need to adjust my FC target up to account for those low-circulation areas?
  20. TDockUSC

    FC in low-circulation areas

    Hey guys, just coming off a SLAM and trying to make sure I don't have the same problem again. I discovered (the hard way) I have a few low-circulation areas in my spa that I wasn't brushing enough. That's where my algae originated. Today I was testing the FC from my normal spot at the deep end...
  21. TDockUSC

    OCLT Results Question

    Yes, I do have a speed stir. It sounds like that might lesson the margin of error, even at this many drops?
  22. TDockUSC

    OCLT Results Question

    Hey guys, currently running my first SLAM (pretty sure I didn't brush enough and got some green in low circulation areas coupled with possibly my FC dropping while on vacation. Lesson learned: BRUSH more!) Anyway, my CYA is 80 so my SLAM target is 31. I'm there right now, pool is crystal clear...
  23. TDockUSC

    Cloudy Water Question

    All very helpful guys, thanks! Just ran home for lunch and it’s already clearer since the pumps been running for over 4 hrs. I’ll continue to monitor and come back if anything else comes up. Thanks again!
  24. TDockUSC

    Cloudy Water Question

    I have an SWG, I just use dicholor very rarely to give FC a boost. Since I tested CYA a week ago, I've only added 4 oz of dicholor which pool math says would only raise it 1.3. According to the chart, 4 is the minimum with 6 the target. I'm raising it back to 6 now, but if it didn't drop below...
  25. TDockUSC

    Cloudy Water Question

    Hi all, I have a question about cloudy water but need to give you a few details first. Thanks to this site, my pool has been crystal clear since install last December. Last night, my son had about 10 friends over and they swam for several hours. Before they swam, I tested the water and these...
  26. TDockUSC

    Pressure Question

    Yes, my water drains from the skimmer in the pool and returns to both the pool and spa when in "pool" setting. In "spa" setting, it drains from the spa and only returns to the spa.
  27. TDockUSC

    Pressure Question

    The equipment is next to the pool and the same height as the pool deck. So it’s probably 6-8 inches above the waterline.
  28. TDockUSC

    Pressure Question

    Thank you for that explanation. Very helpful. I guess my question at this point is do I wait it out for a few days or is there another step to take? Cleaning the basket raised the pressure up to 16, and I normally sit at 18. Is that amount worth worrying about?
  29. TDockUSC

    Pressure Question

    Thanks, duraleigh. Based on your feedback, I checked for obstructions and cleaned out the basket at my pump. That raised the pressure from 14 to 16. While there, I noticed something I else that I had never seen before (but had never really looked at before.) I've attached pics to help clarify...