Search results

  1. blakeusa

    Mottled discolored plaster

    I would contact the Mfg of the plaster and see what they say after reviewing the pics.
  2. blakeusa

    Best Practice - Installing Anchor Cups for Stair Railing in Pavers

    Thanks.. I have the bond wire right in front of the pad... will be connecting to that... and thanks for the other info.
  3. blakeusa

    Best Practice - Installing Anchor Cups for Stair Railing in Pavers

    I have a set of Permacast Big Boy 6 inch brass anchors and a the metal plate. What is the best way/ method to install these in a paver deck. ??? I plan on pouring a 2x2 ft concrete pad then installing the anchors... but not sure on the best way to attatch the plate and cups to the...
  4. blakeusa

    Pentair Intellichlor Bypass (Custom Made)

    I just use an old dead cell and cut the cord off. too lazy to buy or make one. but nice job.
  5. blakeusa

    Multiple rebar rust stains in 9 year old plaster pool - seeking permanent fix

    The problem is that the rebar is not embedded enough in the gunite/ concrete shell. Its possible that they did not shoot enough gunite over the bottom to fully cover and encase the rebar. Even if your plaster was really thick the plaster would suck out the rust from the concrete shell... So...
  6. blakeusa

    Leak in gunite pool - spa inlet

    The crack and lack of bond would need to be all the way through the plaster & the concrete/ gunite shell. Some type of tow part epoxy will only be a band-aid. I hate to say but the spa needs to be chipped out around the leaking return fitting -- all the way through. With the pipe exposed...
  7. blakeusa

    Concrete dividers

    You can apply some Sika rite self leveling adheasive. Its rubbery and will fill the cracks. https://retail.usa.sika.com/en/products/sealants/self-leveling/sikaflexr-self-leveling-sealant-0
  8. blakeusa

    Calcium Nodules

    And a proper replaster should remove 100 percent of the existing plaster to getdown to all hard gunite/concrete shell. Any cracks or problems with the shell should be repaired, then it get washed down, a bond coat and then the new plaster. Calcuim nodules are from the OLD plaster coming...
  9. blakeusa

    Storm Blew Out IntelliCenter

    You may be able to make a homeowners insurance claim.
  10. blakeusa

    Pentair EasyTouch remote has " NO COMM "

    Try powering off the main control panel. Shut off all circuit breakers. First turn off any active pool functions on the panel. Then flip off all the circuit breakers. Wait a minute and flip all back on. It has worked for me in the past... the old Crt Alt Del.
  11. blakeusa

    Installing new Waterway Jets - lube?

    I use a little silicone lube but others are against it because they feel it allows dirt or debris to stick. I have never had a problem but I like lube +.
  12. blakeusa

    Done with Pentair LED’s?

    I have been running my Pentair Intellibrite LED lights for 10 years now. No problems.
  13. blakeusa

    What are you using for Rail Anchors - Brass or Plastic / Pavers

    Installing a couple of sets of stair rails. Q- recommendations on anchor bases and install for paver deck. Was planning on pouring a 2x3 deep concrete cube w mesh then setting anchor plate. Keeping concrete at paver base then using some urethane adhesive for the few pavers ontop of the...
  14. blakeusa

    Paint for pentair meyal light covers

    Anyone have a product that works or do I just replace em. Thanks
  15. blakeusa

    Painted chrome light covers?

    I am working on a pool and the chrome trim rings on the lights seem to have been painted. Before I replace with new has anyone had sucess with painting their covers. They are Pentail Ameri Lights.
  16. blakeusa

    Filling New Pool With Well Water

    Good idea to get water. You would really stress your well running 30k+ gallons
  17. blakeusa

    Anyone use or try Microglass (plaster sealer)?

    I would expect it to be similar to stone and concrete penetrating sealers. You spray and roll it onto dry cured plaster or pebble to seal the plaster. https://www.microglassllc.com/
  18. blakeusa

    HELP! Sub Deck or Paver Instalation Issue ???

    Get a tape measure and check for square. Measure from corner of the pool to corner of the deck on each side. Also do a X measure from corner to corner. If it is not square someone screwed up. If its the concrete pad I would just have the paver company cut the edge straight with a concrete saw...
  19. blakeusa

    Adding new hand railing to paver deck or first step underwater? Recommendations

    Looking at installing a new SR Smith Art-1004 railing to my pool. Dimensions make it more functional if I was to install it using the first step (underwater) to attatch the anchors vs deck mount. If I deck mount it is too high (for my wife) and does not extend into the pool enough. She has...
  20. blakeusa

    Adding 3rd Valve/Actuator to my EasyTouch 8 System

    UNDER RATED POST and SOLUTION. Good job Pohoda & Jhva & TFP :) This IMHO would be the best soution to adding additional 24V valve actuators to an Easytouch Automation System. Thanks Blake :)
  21. blakeusa

    Pentair ic40 salt cells not available?

    My local New England parts distributor has not had cells for over a year. Are they available in other areas or states.... Any aftermarket cells compatible with the pentair control box
  22. blakeusa

    Recommendations for Chlorine Tabs?

    I have two pools that the Pentair Salt Cells are dying or dead. They are not available from the manufacturer.. all on backorder. So recommendations for some Chlorine tabs to let float in the pool or skimmer. Thanks in advance.
  23. blakeusa

    Concrete coping eroding (pitting) - how to stop

    There are non wet / non slip looking concrete sealers. You can apply them yourself with a paint brush. Can't think of the name of a good one we used before but there are several. Just do not buy at a box store. Get at a concrete supply company or online. The popping us due to air...
  24. blakeusa

    IC40 no LED's on Output only

    Just getting back on this... unfortunately this pool does not have Screenlogic. Just the power box and cell. Works on Shock Mode where all lights blink but does not show any LED's on basic inputs ie 20,40,60 etc. Going to go back out today and reset the system again and call Pentair.
  25. blakeusa

    IC40 no LED's on Output only

    Have a IC40 that has power and flow but no lights on the Output (increase chlorine) buttons. Cell is about 3 years old. Need to test to see if its producing later today. Any ideas or feedback. Thanks
  26. blakeusa

    Installing Stair railing w. 1 post underwater -best way

    Thanks.. yes Art-1004 was my second option.
  27. blakeusa

    Installing Stair railing w. 1 post underwater -best way

    Looking to install a stair rail where one post sits underwater on a stair. I would expect that I could use a deck mount anchor below the waterline - but what is the best way to do this without draining the water. ?
  28. blakeusa

    Exposed rebar and plumbing after gunite

    The exposed areas on the exterior of the pool can be patched or repaired with concrete with a bonding agent and are not that big of a deal. The entire gaps need to be sealed. I would then request a waterproof agent by applied to those areas on the exterior. This will get backfilled so not...