  1. A

    questions about replacing salt cell for first time

    thank you so much!! glad to know it's still performing well. I'll check the performance periodically.
  2. A

    questions about replacing salt cell for first time

    omg, I am so dumb! I was trying to reset the check cell light by using the switch... it was a really long winter and cold spring so my pool procedure memories are clearly slow to wake up! I can't believe that I got something so obvious wrong. duh.. For future knowledge, how much longer can I...
  3. A

    questions about replacing salt cell for first time

    I will try replacing the display board this weekend. When I turned it on/off I got 3000 instant salinity both times (occasionally switching to 3100). The T-9 cell is 3E1102. This means 2011? Maybe the box was replaced but the cell was still okay? I see no signs that the T-9 was ever used...
  4. A

    questions about replacing salt cell for first time

    3E0907 AQR-CUL 3A1106 When I switch to super chlorinate I can see the instant salinity switching between 3000-3100 and I think was the amps that was changing. I tried off and unplugging the cell. same result. When you say to reset the display board do you mean just take it off and put it back on?
  5. A

    questions about replacing salt cell for first time

    I corrected my post to T-9. I had a power failure overnight which tripped the breaker so these could be a little off, however I did a manual test with my reagents and got reading of 3100. 3.00 18 31.9 0.00 14p -0.00 al-1 r1.58 t-15 do you need serial number of the cell or the panel? where do...
  6. A

    questions about replacing salt cell for first time

    I've had the same T-15 cell for 7 years. I don't know how long the previous owner had it. It is giving Inspect Cell message which I cannot clear. The green generating light is on so does this mean it is working but at reduce rate?? I assume this means that it needs replacing?? The old owner...
  7. A

    no power light on swg - current limiter failed again??

    Thanks. I replaced with an AS32 last time... I think that is what the original was. I ordered 2 from digi-key this time!!
  8. A

    no power light on swg - current limiter failed again??

    No green power light on my swg. I replaced the current delimiter two years ago but only ordered one thinking they lasted a long time. How long should they last?? I can't remember if it was same thing but seeing other posts seems to indicate the same component has failed again... The display...
  9. A

    ideal setting for swg w dual speed pump?

    Thanks for the feedback. I don't know anything about timers, I'll look into it.
  10. A

    ideal setting for swg w dual speed pump?

    Is there a guideline to determine what setting I should have my swg at if running my pump on low vs high, or is it just trial and error? I have a 1hp Hayward super pump with an Aquarite t-15 cell. 12000 gallon vinyl pool. No timer, just a high/low switch. Now that I've discovered what dual...