Search results

  1. F

    best way to reinstall spillover spa

    I was just going to make one of the stones thinner rather than cut into the spa wall will look into laticrete 254 thanks
  2. F

    best way to reinstall spillover spa

    thats my spillover spa the water is supposed to flood over the lip of these rocks more or less evenly
  3. F

    best way to reinstall spillover spa

    I have had to repair my spillover for my spa 3x in 10 years each time the mortar fails as water undermines the 5 stones each stone is indiana ledgerock about 3-4 inches thick with a crack of about 1/2 inch between the stones they are laid on a bed of mortar and then grouted together in the...
  4. F

    looking for a jandy controller expert for a problem jandy cant solve

    replaced the controller wire and the thing works !! they told me not to bother as it cannot be the wire but it seems like it was fs
  5. F

    looking for a jandy controller expert for a problem jandy cant solve

    I have a jandy controller RS 8 with T revision My heater is a jandy LXI which is plugged into slot 1 2 of the 10 pin connector not into the RS 485 4 pin port and worked fine until recently now The heater works fine in manual mode but I can no longer control it when the heater is set to be...
  6. F

    Unable to control a Jandy LXI heater

    oops - I forgot to ask - re connecting more devices there are 2 red connectors - with 4 pins does it make any difference which one I use or are they both the same and where does one buy the actual connector that slides onto the 4 pins
  7. F

    Unable to control a Jandy LXI heater

    1.My Jandy LXI Heater is working fine in manual mode but I cannot control it with my Jandy RS controller. Yesterday I installed a new CPU and bezel control board ( I am planning on a multi speed pump and needed a newer revision of firmware ) and I hoped it would get rid of the problem but still...
  8. F

    plumbing problem

    Great idea the problem would be how to plumb the suction from the spa which would become a 180
  9. F

    plumbing problem

    Originally there was a skimmer and drain dedicated to bringing water back from the spa to main pump as you can see in the picture this was capped because of a leak if you look at the picture and follow the spa side of the Jandy you can see the stub in the ground so all water from the spa comes...
  10. F

    plumbing problem

    Can you explain how and where the valves would go and what NM is in spa mode the water returns from the spa and is split into two streams part to the heater and back to spa and part to the spa pump and bypassing the filters and heater
  11. F

    plumbing problem

    True - wonder what people think about my idea or if they have a better one can you explain how adding a couple of cinder blocks would make it easier to plumb? fs
  12. F

    plumbing problem

    I have decided to change out my main pump to add a variable speed jandy jep 2.0 epump the old pump is about 25 inches and is a 1 hp The new one is about 35 inches and 2 hp I have 4 suctions going to the main pump, 3 on the pool and 1 on the spa controlled by a jandy valve creating a manifold...
  13. F

    Jandy Pool Actuator Problem Zodiac Unable to help

    great idea I did switch the positions on the controller and the problem did NOT go away. This led me to believe that there was something wrong with the actuator or the wire to the actuator. I took apart the actuator and checked the microswitchs and the left one works when the toggle is down...
  14. F

    Jandy Pool Actuator Problem Zodiac Unable to help

    Have a spillover spa pool with jandy aqualink and 2 jandy 2440 actuators one to switch suction from the pool three suctions to spa and the second to divert water from the spa return to the pool returns. The problem is the second one When I am in service mode and put the pool into spa both...