    Solar Valve No Longer Automatic

    Is solar enabled in the configuration menu? The solar temperature must also be set in the settings menu.
  2. mas985

    No pressure after using vacuum

    It prevents debris from getting stuck in the suction pipe or the pump impeller. So there could be two areas were the debris got stuck. Either in the pump impeller or the suction pipe. Does the pump basket have a lot of air in it? If so, it is likely the suction pipe. If not, then it is probably...
  3. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    Perhaps but I suspect it is far from a hard start like a 1 or 2 speed pump.
  4. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    It isn't just about cost, 230 watts * 24 hrs * 365 days ~ 1 Ton of CO2/yr Also, VS pumps do not suffer from on/off fatigue as they ramp speeds much slower than an induction motor so there is less stress on the mechanical parts.
  5. 1620746586699.png

    1620746586699.png

  6. mas985

    No pressure after using vacuum

    Did you clean out the pump basket after vacuuming? You should be using a vacuum plate in the skimmer.
  7. mas985

    Newbie wanting to a pump that can handle pushing water up high and over distance

    Welcome to the forum! Most any pump should be able to do that. About the only exception is an Intex pump. They are much weaker pumps. What kind of pump do you have?
  8. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    $0.15/kwh in CA? I'm not sure about the OP but I pay more than twice that.
  9. mas985

    Bubbles in return - is this a problem?

    It depends on the plumbing setup and the head curve of the pump. Have you measured flow rate in any way or felt the panels? Warm panels usually indicates lower than optimal flow rate. You want at least 0.1 GPM/sq-ft of panels.
  10. mas985

    Bubbles in return - is this a problem?

    For 15 feet, your filter pressure probably needs to be above 8 PSI to keep the VRV closed. What is the filter pressure now?
  11. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    I do not run 24 hrs per day. I have very high electrical costs so 24 hr is a big bump in costs. In the summer, I run at about 1500 RPM, I have two skimmers which requires more flow rate, and for about 9 hrs per day, mainly for solar gain. In the winter, I run only two hours per day at the same...
  12. mas985

    Bubbles in return - is this a problem?

    #1 would not cause bubbles out of the returns. However, it does cause bubbles to accumulate in the pump basket. #2 is the most likely cause of your problem. Higher speeds/pressure is necessary to keep the VRV closed. How high is the VRV in relation to the pump?
  13. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    Filtering does nothing for sanitation. Only chlorine is necessary for sanitation. Filtering is merely an aesthetic task, it just makes the pool look better. But one thing to keep in mind is that most debris in a pool either sinks or floats. Any very tiny particles that are suspended in the pool...
  14. mas985

    Featured Why is calculating run-time for my new VS motor so difficult?

    You still seem to be focused on turnovers. The number of gallons pumped in a 24 hour period is totally irrelevant. What is it you are really trying to accomplish with all this?
  15. mas985

    plumbing install for my Stenner pump

    Either pipe tape or plumbers putty.
  16. mas985

    plumbing install for my Stenner pump

    I have a different perspective on 1/2" vs 1/4". The problem with 1/2" is that the curvature of the pipe may not allow for a good seal (i.e. exposed thread). Also, should someone hit the connection, would you rather the inserted fitting break or the pipe/thread break? I think 1/4" is actually a...
  17. mas985

    plumbing install for my Stenner pump

    Not sure what you mean by double. Through a fitting and pipe at glue joint? No, I would not do that as it could compromise the glue joint. Pipe is a little less brittle than fittings so I tend to lean that way.
  18. mas985

    Losing 3ppm per day?

    Losing 3 out of 5, is 60% UV extinction which is actually quite good for a CYA of 40. As you increase CYA, you FC UV loss will drop.
  19. mas985

    Losing 3ppm per day?

    What is your target FC level? I have you done an OCLT?
  20. mas985

    plumbing install for my Stenner pump

    I would just drill and tap for 1/4". You are making it much harder than it needs to be. Downstream, closer to the returns is best because pressure is at it's lowest. Is this for acid or chlorine?
  21. mas985

    Saltwater Solar Blanket Deterioration

    Not in terms of life. They were both the same, about two seasons. However, my latest cover is going on 4 years but there is a caveat. The first year I used it quite a bit but haven't really used it much since. Keeping it out of the pool extends the life significantly. I think UV exposure is...
  22. mas985

    New DIY Vinly Pool Build - (OH)

    Ok, then why not use a waterfall pump?
  23. mas985

    Water Feature and SPA JET Plumbing Question

    Then why would matter if both pumps were running? Maybe I am missing something. If pumps are on isolated plumbing systems, they will have no effect on each other.
  24. mas985

    Water Feature and SPA JET Plumbing Question

    It is difficult to see how the pool and waterfall MDs are plumbed to their respective lines. Are each their own or are they sharing both MD's?
  25. mas985

    Best solution to fix air leak at pump fitting

    Yes, scrape out the old putty as much as you can. First try the pool lube and see if it works and lasts. If not, move on to the plumber's putty. You can soften the plumbers putty with a little water. But for both, apply while the pump is running. You will know right away if the gap is too big as...
  26. mas985

    Best solution to fix air leak at pump fitting

    Some alternatives to cutting out the plumbing: Suction side leaks are usually easier to fix than pressure side since with the pump running, the leak will draw in air or anything else you might put on it. If it is a very tiny leak, sometimes pool lube is enough to get sucked into the gap and...
  27. mas985

    Pump positioning in relation to filter

    The distances you are describing are not an issue.
  28. mas985

    Pump positioning in relation to filter

    If the gauge does not read 0 when the pump is shut off, the gauge is bad. It needs to be replaced.
  29. mas985

    Maytronics Robot Cleaner and Optimum Pool

    The all have there advantages and disadvantages. Have you compared the features sets on the Maytronics site: https://maytronicsus.com/product/residential/m200/ https://maytronicsus.com/product/residential/active-10/ https://maytronicsus.com/product/residential/s50/ The Active 10 and S50 are...