Search results

  1. K

    Waterway Oasis and Hayward VS 950 - Wiring Question

    Finally figured all this out using the relays. The documentation for the Hayward VS 950 is inaccurate, so using a combination of relays and timer speed settings, instead of regular speed settings worked. Not as a VS pump, but as a two speed pump, which is fine for my needs. Thanks all for the...
  2. K

    Waterway Oasis and Hayward VS 950 - Wiring Question

    I spent some time attempting this. I'm having the same issue. According to Hayward documentation, based on the drive comm version, there are two scenarios. With zero relay inputs closed, the pump will stop or with input 3 closed it will remain stopped. I cannot get this darn pump to stop without...
  3. K

    Waterway Oasis and Hayward VS 950 - Wiring Question

    So, hooking up the two wires per the manual works..... kind of.... It starts the pump and does control the speed, however, it doesn't stop the pump. Adding the third wire actually starts the pump when it's off, so something isn't quite right. Suggestions?
  4. K

    Waterway Oasis and Hayward VS 950 - Wiring Question

    I'll give it a try. Hope to be working on it over the next few days and will report back. Thanks!
  5. K

    Waterway Oasis and Hayward VS 950 - Wiring Question

    I bought the Waterway Oasis automation kit with Wifi and 2 Actuators. Just getting around to installing and have one issue. The manual states that is is compatible with many VS pumps, Waterway (obviously), Jandy, Hayward and Pentair. However, for the Hayward VS pumps it shows only two wire...
  6. K

    Hayward H400FDP won't fire

    Outside with plenty of air. It's been 2 or 3 years since I had it serviced. All working well after removing and cleaning the first burner tube. Will give it a good clean this season.
  7. K

    Hayward H400FDP won't fire

    I took out the first burner, cleaned it up a little and it fired right up. I think I'll get somebody out to give it a thorough service/cleaning. Thanks folks for taking a look at this. Am still interested to know if the black stuff either side of the burner is some sort of insulation or if it is...
  8. K

    Hayward H400FDP won't fire

    Followed the service guide and it certainly seemed as though the gas valve was at fault. There was zero smell of propane at all and everything else seemed good after receiving the "IF" error code. I switched out the gas valve and now I do smell a little propane when it tries to fire, but nothing...
  9. K

    Cover Cost for Brand New Pool

    I had a 42x22 free form in ground pool built this summer. There is also a spa on one end and a 6ft wide rock waterfall near the deep end. The deck is dry set travertine. One company has provided me with a quote for the cover (GLI ProMesh), installation and closing of the pool for $6400.00. Does...