    Baffling In Ground Spa Leak

    Correct. - - - Updated - - - Spa returns. I think in that position (middle) you get some flow to the spa jets in pool mode to have the water spill over. In spa mode it moves to the right for full flow to the jets. Am assuming full left is no flow to the jets.
  2. P

    Baffling In Ground Spa Leak

    I do manual shutoff from interior Jandy control and using the breaker outside. Both have same result - negligible leak.
  3. P

    Baffling In Ground Spa Leak

    I do manual shutoff from interior Jandy control and using the breaker outside. Both have same result - negligible leak. - - - Updated - - - Have not looked at the check valves as I assumed that since I had a large net loss of water, as opposed to going between the pool and spa, that they...
  4. P

    Baffling In Ground Spa Leak

    Seems that would put the water into the pool rather than disappearing - true? Pool level does not rise when the 500 gallons goes missing.
  5. P

    Baffling In Ground Spa Leak

    Have an in ground spa and pool. Spa is raised above pool by a couple of feet (see pics attached). Some mornings before the pump comes on I have lost half the water in my spa (about to the jet line - approx. 500 gallons). Others mornings there is negligible water missing. Does not seem to be...
  6. P

    Hayward H250IDL no blower, no ignition sequence

    Cleaned the ground connection on the blower (slightly rusty) and the heater fired right up......never have such good luck but why question success....thanks.
  7. P

    Hayward H250IDL no blower, no ignition sequence

    I placed the heater in manual mode via the dip switch and then turned on spa mode. Nothing for 1 minute then AO error code. Blower never runs and no ignition attempted. Thoughts?
  8. P

    Hayward H250IDL no blower, no ignition sequence

    I have a Hayward H250IDL spa heater, 13 years old, controlled from a Jandy control panel (heater is in bypass mode). When in spa mode, the heater does not activate the blower and the ignition cycle never proceeds. No error codes are displayed. It just sits there and does nothing. I replaced...