Our setups are similar and we have the same pump. 2200 should be fine.
That all makes sense. I feel like I have turned my HP on already to just test it and it has turned on. Maybe the pump was at a higher setting when I tested it. I’ll have to play around with it one day soonI had a heat pump for 8.5 years and never knew my flow. I speak RPM and not GPM.
Just like the SWG, start low and increase RPM 100 at a time and when the HP turns on, thats the flow it needs. Your flow will be restricted slightly as thr filter gets dirty so add 100 RPMs and thats the speed you need to run for the heater.
Footage to the equipment matters, and so does pool to pad elevation. The general set up can be the same and also very different.
Okay so my PB installed a flow meter on another poop last year and he asked the guy for info at different RPMs what the flow was. This guy has the same exact set up as me, but equipment but his pad is actually 10ft or so farther than mine according to my PB. These readings are from a 18x36 pool (kidney shaped) with the same depth, minus the sun shelf. So probably a couple thousand less gallons than mine. So I will need a little more rpms to achieve the same GPM flow.Our setups are similar and we have the same pump. 2200 should be fine.
He said he installed the exact same equipment as mine at this guys house. So I have to take his word for it. He is looking to see if he has a picture of the equipment pad in his photos.When you say EXACT SAME SETUP, are you sure about the pump model, filter model and size, and the same AcquaCal 145?
Have him send a picture of the setup. HPs are fairly restrictive, I'm really surprised you can get 35 GPM at 1600RPM with a superflo...
If you can, that's good for you!
@mas985, what do you think?
Equipment might be the same, but are the pipe run lengths, pipe size, fitting counts, valves, skimmers, main drains, return eyeball diameters, etc. identical? Everything that touches the water through the plumbing affects the pump operating point and it would be extremely rare for two pools to have identical operating points because the plumbing layouts are almost never the same.He said he installed the exact same equipment as mine at this guys house. So I have to take his word for it. He is looking to see if he has a picture of the equipment pad in his photos.
But very similar size pool.
As I said earlier, the pressure switches are really not accurate, most are set lower than the flow threshold, manufacturers should put in FLOW switches.Alright just went out and played around with RPMs. At 1900RPMs the heat pump kicks on. So that must be where I’m getting 30gpm. So would 2000rpms suffice to run 24/7?
Alright sounds good. The extra 300rpms won’t kill me haha. Set it back to 2200 for 24/7As I said earlier, the pressure switches are really not accurate, most are set lower than the flow threshold, manufacturers should put in FLOW switches.
Why do you think they recommend the calibration port? So you can ensure the temperature rise TELLS you you have adequate flow.
My recommendation stands.
- Run at 2200-2400. Heaters are very expensive to replace, a bit of electricity is insurance to not kill the heater because it overheated with low flow.
- Or, get a flow meter to determine you are getting the flow. Put it after the heater.
- Or do as the manual recommends, install the port and measure the temperature rise.
AquaCal heat pumps may have a delay before the compressor starts, typically 3 to 4 minutes, after the unit is turned on or when calling for heating or cooling. This allows the fan to operate and ensures proper water flow before the compressor engages.Not sure what compressor delay means
Makes sense. Thanks.AquaCal heat pumps may have a delay before the compressor starts, typically 3 to 4 minutes, after the unit is turned on or when calling for heating or cooling. This allows the fan to operate and ensures proper water flow before the compressor engages.
Maybe I’ll click mine down a little more tomorrow. Just trying to figure out the sweet spot for now. Obviously just started out doing all this. Hence all of the questionsMin is on 5. Low UV this time of year...and cold water.
^^^What Allen says. Don't fret it. Just keep it at or above the top of the range for your CYA. If top of target is 10, and runs a little hot for a week and you end up at 12.5, why does it matter? Fiddle if you like, I don't fiddle, but maybe once a week.At CYA 70 it is safe to swim up to 28 FC.
Ok good. And yes we plan to get one and a reel to cover everything but the sun shelf. But am waiting until the concrete is poured sometime in June. Why?^^^What Allen says. Don't fret it. Just keep it at or above the top of the range for your CYA. If top of target is 10, and runs a little hot for a week and you end up at 12.5, why does it matter? Fiddle if you like, I don't fiddle, but maybe once a week.
And, if you are above range and have a bunch of people over on a hot/sunning day in June/July, your pool can handle it.
Do you have a solar cover, or intend to get one?
You are about the same lattitude...so same same. Cover will reduce FC consumption.Ok good. And yes we plan to get one and a reel to cover everything but the sun shelf. But am waiting until the concrete is poured sometime in June. Why?
Great info. Thanks!!You are about the same lattitude...so same same. Cover will reduce FC consumption.
This is what I do:
This system just works for me. Might work for you!
- Don't try to micromanage the % output daily. Once you know what it takes (log everything in PM), you will learn what % to run each month.
- FC can drift up/down over the week. Since it is safe up to slam level just keep it within range or a bit above.
- With the cover on, (May, early June) I run 5-10%. June/July 15%, Aug/Sep 10-15%. You will find your ranges.
- When we get in to swim and cover comes off, SWG goes to 50 or 60% depending on the number of people, the sun etc. When we are done, and cover goes on, SWG goes back to baseline (or I might leave it on until 8 or 9). The increase output while swimming offsets the demand. That way I only have to change the output when we are out there, or have to wait to test at the end of the day, adjust output up, then remember to turn if off in the morning.
- ^^^Your cell makes 8FC in 24 hours in your pool. Mine makes 13 in my pool. Me turning it 50% on for 6 hours will make 1.5 (additional demand from swimmers). That would me you would need to run closer to 70/80/90 to make up the same. If you try this route, when you open turn it up to 80, then back down, see how that works.