Opened pool
Water Clear
All equip in working order.
Closed PoolVacuumed
37 oz of 31.45% (20º Be) Muriatic Acid
14.0
FC
8.2
pH
0.67
CSI
16.5
FC
0.0
CC
140
TA
350
CH
40
CYA
70 °F
TEMP
0.67
CSI
49 oz of 31.45% (20º Be) Muriatic Acid
11.5
FC
8.2
pH
0.79
CSI
12.5
FC
0.5
CC
85 °F
TEMP
0.39
CSI
11.5
FC
50
CYA
0.39
CSI
11.5
FC
0.37
CSI
11.5
FC
0.37
CSI
Increased SWCG to 60%
82 oz of Liquid Chlorine • 12.5%
6.0
FC
70
CYA
0.37
CSI
6.5
FC
7.8
pH
0.39
CSI
38 oz of Dry Stabilizer
6.5
FC
8.0
pH
0.59
CSI
Turned Salt cell back up to 50
86 oz of Liquid Chlorine • 12.5%
40 oz of 31.45% (20º Be) Muriatic Acid
3.0
FC
0.0
CC
7.8
pH
0.39
CSI
8.0
FC
0.0
CC
7.5
pH
150
TA
325
CH
50
CYA
2740
SALT
85 °F
TEMP
0.10
CSI
12.0
FC
0.0
CC
50
CYA
87 °F
TEMP
0.74
CSI
2 lbs of Dry Stabilizer
50 oz of 31.45% (20º Be) Muriatic Acid
10.5
FC
0.0
CC
8.2
pH
125
TA
40
CYA
85 °F
TEMP
0.74
CSI
11.0
FC
0.5
CC
7.8
pH
0.39
CSI
12.5
FC
0.10
CSI
VacuumedBrushed
40 lbs of Salt
15.0
FC
0.0
CC
2750
SALT
0.10
CSI
48 oz of 31.45% (20º Be) Muriatic Acid
15.5
FC
0.5
CC
0.10
CSI
8.5
FC
0.0
CC
7.5
pH
2750
SALT
86 °F
TEMP
0.10
CSI
102 oz of 31.45% (20º Be) Muriatic Acid
14.0
FC
8.0
pH
0.59
CSI
16.0
FC
0.00
CSI
15.0
FC
0.00
CSI
17.0
FC
85 °F
TEMP
0.00
CSI
24.0
FC
0.03
CSI
2 gal of Liquid Chlorine • 12.5%
12.5
FC
0.03
CSI
3 gal of Liquid Chlorine • 12.5%
20 lbs of Salt
0.0
FC
0.0
CC
7.4
pH
2520
SALT
0.03
CSI
7.0
FC
0.0
CC
7.6
pH
140
TA
89 °F
TEMP
0.16
CSI
7.0
FC
0.0
CC
7.8
pH
0.20
CSI
7.5
FC
7.4
pH
-0.19
CSI
64 oz of Liquid Chlorine • 12.5%
48 oz of 31.45% (20º Be) Muriatic Acid
5.5
FC
0.0
CC
8.0
pH
0.40
CSI
Up SWCG to 30%
4.0
FC
0.0
CC
7.8
pH
0.20
CSI
Turning SWCG back on to maintain 7ppm. 20%.
7.0
FC
0.0
CC
7.8
pH
0.20
CSI
9.0
FC
0.0
CC
7.8
pH
70 °F
TEMP
0.20
CSI
12.0
FC
-0.09
CSI
Salt cell was on 30. Turning off and opening pool cover. It’s going to rain this wknd.
16.0
FC
-0.09
CSI
9.0
FC
0.0
CC
7.6
pH
-0.09
CSI
10.0
FC
0.5
CC
7.5
pH
140
TA
350
CH
60
CYA
60 °F
TEMP
-0.19
CSI
Opened PoolBrushed
Closed PoolVacuumedBackwashed
16.5
FC
0.0
CC
8.0
pH
170
TA
375
CH
70
CYA
53 °F
TEMP
0.35
CSI
40 oz of 31.45% (20º Be) Muriatic Acid
12.5
FC
0.5
CC
7.8
pH
87 °F
TEMP
0.22
CSI
6.5
FC
0.0
CC
7.5
pH
150
TA
250
CH
70
CYA
3850
SALT
80 °F
TEMP
-0.13
CSI
45 oz of Liquid Chlorine • 12.5%
54 oz of 31.45% (20º Be) Muriatic Acid
4.0
FC
0.0
CC
8.0
pH
0.51
CSI
5.5
FC
0.0
CC
0.71
CSI
51 oz of Liquid Chlorine • 12.5%
4.5
FC
0.0
CC
8.2
pH
160
TA
70
CYA
83 °F
TEMP
0.71
CSI
7.0
FC
0.0
CC
7.8
pH
85 °F
TEMP
0.30
CSI
Chlorine 10.5
Turn SWCG down to 30
85 oz of 31.45% (20º Be) Muriatic Acid
10.5
FC
8.2
pH
0.72
CSI
SWCG from 50% down to 40%
12.5
FC
0.0
CC
7.8
pH
89 °F
TEMP
0.33
CSI
81 oz of 31.45% (20º Be) Muriatic Acid
6.5
FC
0.5
CC
0.51
CSI
8.0
FC
0.0
CC
8.0
pH
0.51
CSI
11.5
FC
0.51
CSI
Turned SWCG down from 60 to 40 bc CL was 15
11.0
FC
0.0
CC
0.51
CSI
9.0
FC
8.0
pH
70
CYA
87 °F
TEMP
0.51
CSI
11.0
FC
0.5
CC
7.8
pH
50
CYA
85 °F
TEMP
0.32
CSI
72 oz of 31.45% (20º Be) Muriatic Acid
102 oz of Liquid Chlorine • 10%
5.5
FC
8.2
CC
89 °F
TEMP
0.34
CSI
7.5
FC
0.0
CC
0.32
CSI
5.5
FC
0.32
CSI
6.0
FC
7.8
pH
0.32
CSI
61 oz of Liquid Chlorine • 12.5%
5.0
FC
0.32
CSI
24 oz of Dry Stabilizer
6.0
FC
0.32
CSI
8.0
FC
0.0
CC
0.32
CSI
128 oz of Liquid Chlorine • 12.5%
2.0
FC
0.0
CC
0.32
CSI
Cleaned calcium off of SWCG
Bumped SWCG up to 70 from 60. FC keeps falling, but it has been very hot in the 90’s.
4.0
FC
0.0
CC
7.8
pH
150
TA
300
CH
60
CYA
3580
SALT
87 °F
TEMP
0.32
CSI
128 oz of Liquid Chlorine • 12.5%
3.5
FC
0.5
CC
7.6
pH
86 °F
TEMP
0.08
CSI
75 oz of 31.45% (20º Be) Muriatic Acid
7.0
FC
0.0
CC
8.2
pH
0.68
CSI
8.5
FC
0.0
CC
8.2
pH
0.68
CSI
7.0
FC
0.0
CC
0.29
CSI
Bumped SWCG to 50 from 30
128 gal of Liquid Chlorine • 12.5%
0.5
FC
7.8
pH
0.29
CSI
6.0
FC
0.0
CC
0.00
CSI
7.0
FC
0.5
CC
7.5
pH
0.00
CSI
15.0
FC
0.0
CC
60
CYA
89 °F
TEMP
-0.29
CSI
10.5
FC
0.0
CC
7.2
pH
40
CYA
85 °F
TEMP
-0.30
CSI
3 lbs of Dry Stabilizer
SWCG making too much CL. Turned down from 50 to 20. Left cover open to uv and rain.
15.0
FC
0.0
CC
130
TA
0.29
CSI
63 oz of 31.45% (20º Be) Muriatic Acid
12.5
FC
0.0
CC
7.8
pH
0.29
CSI
Did an OCLT last night. Left salt cell running. Chlorine went up 3.5ppm. Pool water is clear this morning. Will dial SWCG back down to 50.
19.0
FC
0.0
CC
-0.30
CSI
16.5
FC
-0.30
CSI
4.0
FC
0.5
CC
-0.30
CSI
Water cloudy.
Added a gal of chlorine to get water to 7ppm.
Increased SWCG from 50 to 70%.
0.5
FC
0.0
CC
7.2
pH
130
TA
40
CYA
85 °F
TEMP
-0.30
CSI
35 oz of 31.45% (20º Be) Muriatic Acid
7.5
FC
0.0
CC
7.8
pH
85 °F
TEMP
0.27
CSI
128 oz of Liquid Chlorine • 12.5%
3.0
FC
0.0
CC
7.5
pH
50
CYA
3060
SALT
85 °F
TEMP
-0.02
CSI
2.5 lbs of Dry Stabilizer
40 lbs of Salt
VacuumedBackwashed
28 oz of 31.45% (20º Be) Muriatic Acid
7.0
FC
0.0
CC
7.8
pH
130
TA
300
CH
40
CYA
2610
SALT
60 °F
TEMP
0.08
CSI
Opened Pool
Opened Pool
77 oz of 31.45% (20º Be) Muriatic Acid
20.0
FC
0.0
CC
8.2
pH
200
TA
325
CH
40
CYA
2830
SALT
50 °F
TEMP
0.62
CSI
Cleaned salt cell
Bumped SWCG up to 50.
64 oz of Liquid Chlorine • 12.5%
85 oz of 31.45% (20º Be) Muriatic Acid
3.5
FC
0.0
CC
8.2
pH
0.73
CSI
51 oz of 31.45% (20º Be) Muriatic Acid
72 oz of Liquid Chlorine • 12.5%
4.5
FC
0.0
CC
8.0
pH
0.53
CSI
7.0
FC
0.0
CC
8.2
pH
87 °F
TEMP
0.73
CSI
5.0
FC
0.0
CC
8.0
pH
0.53
CSI
61 oz of Liquid Chlorine • 12.5%
5.0
FC
0.0
CC
0.33
CSI
6.0
FC
0.0
CC
7.8
pH
0.33
CSI
10.0
FC
0.0
CC
7.8
pH
0.33
CSI
Turned SWG down to 30 from 50 to lower chlorine.
13.0
FC
0.0
CC
8.2
pH
86 °F
TEMP
0.73
CSI
18.5
FC
0.0
CC
8.2
pH
85 °F
TEMP
0.71
CSI
8.0
FC
0.0
CC
7.8
pH
0.35
CSI
11.0
FC
7.8
pH
0.35
CSI
11.0
FC
0.0
CC
0.35
CSI
Cover has been closed the last 2 days bc rain. Water looks good. Notice some dead algae on the liner seams. Going to turn SWCG down from 60 to 40 and test water this evening and probably bump back up to 50 for heavy
15.0
FC
0.0
CC
7.8
pH
70
CYA
88 °F
TEMP
0.35
CSI
6.0
FC
0.0
CC
7.5
pH
150
TA
0.06
CSI
Increased SWCG to 60%.
PH no longer stable. Added 106 oz of MA to bring TA down. Aerating to bring up.
106 oz of 31.45% (20º Be) Muriatic Acid
5.5
FC
0.0
CC
8.2
pH
0.67
CSI
35 oz of 31.45% (20º Be) Muriatic Acid
8.0
FC
0.0
CC
8.2
pH
0.67
CSI
11.5
FC
70
CYA
0.28
CSI
9.0
FC
0.0
CC
7.8
pH
0.30
CSI
24 oz of 31.45% (20º Be) Muriatic Acid
7.8
pH
0.30
CSI
53 oz of Dry Stabilizer
11.0
FC
0.5
CC
130
TA
50
CYA
3060
SALT
88 °F
TEMP
0.01
CSI
Left water on to top off pool too long. Backwashed, rinsed & dumped to waste.
Turned salt cell back on @ 50%.
13.0
FC
-0.10
CSI
Turning SWCG off for 24 hrs to let FC fall.
22.0
FC
-0.10
CSI
Cover was closed all day.
24.0
FC
0.5
CC
-0.10
CSI
24.0
FC
0.5
CC
-0.10
CSI
26.0
FC
0.5
CC
-0.10
CSI
72 oz of Liquid Chlorine • 12.5%
20.5
FC
-0.10
CSI
1 gal of Liquid Chlorine • 12.5%
18.5
FC
0.0
CC
-0.10
CSI
22.5
FC
0.0
CC
-0.10
CSI
Added 2.6 gal to SLAM FC up to 24 bc we had a pool party today and the pool water was a little cloudy when we opened it this afternoon. FC has been holding around 7. SWCG is at 50%. It’s been very hot this week.
2.6 gal of Liquid Chlorine • 12.5%
7.5
FC
-0.10
CSI
50 oz of Liquid Chlorine • 12.5%
6.5
FC
7.5
pH
-0.10
CSI
61 oz of Liquid Chlorine • 12.5%
4.0
FC
0.0
CC
7.5
pH
-0.10
CSI
8.5
FC
7.5
pH
-0.10
CSI
8.0
FC
7.8
pH
0.19
CSI
SWCG set to 40%
13.0
FC
-0.38
CSI
SWCG is running at 20%. Need to get FC down. Turning it off for 24 hours and retesting. Sunny today.
21.0
FC
-0.38
CSI
18.5
FC
-0.38
CSI
24.0
FC
-0.38
CSI
27.0
FC
-0.38
CSI
28.0
FC
-0.38
CSI
SWCG ran at 100% since last test. Something is eating chlorine. SLAM started
524 oz of Liquid Chlorine • 10%
3.5
FC
0.0
CC
7.2
pH
120
TA
300
CH
60
CYA
3580
SALT
85 °F
TEMP
-0.38
CSI
2.0
FC
0.0
CC
7.2
pH
91 °F
TEMP
-0.31
CSI
7.0
FC
0.0
CC
7.2
pH
130
TA
-0.30
CSI
7.5
FC
1.0
CC
7.5
pH
60
CYA
92 °F
TEMP
-0.01
CSI
14.0
FC
-0.30
CSI
17.5
FC
7.2
pH
-0.30
CSI
4 lbs of Dry Stabilizer
71 oz of 31.45% (20º Be) Muriatic Acid
17.0
FC
0.0
CC
8.0
pH
30
CYA
88 °F
TEMP
0.49
CSI
Set SWG to 50% last night. FC up to 10 from 5
10.0
FC
0.0
CC
7.4
pH
130
TA
50
CYA
-0.26
CSI
5.0
FC
72 °F
TEMP
0.06
CSI
4 lbs of Dry Stabilizer
28 oz of 31.45% (20º Be) Muriatic Acid
0.5 lbs of Dry Stabilizer
Increased SWG from 20 to 40
Vacuumed
3.5
FC
0.5
CC
7.8
pH
100
TA
300
CH
10
CYA
3890
SALT
70 °F
TEMP
0.05
CSI
24 oz of 31.45% (20º Be) Muriatic Acid
1 gal of Liquid Chlorine • 12.5%
4.0
FC
7.8
pH
90
TA
300
CH
59 °F
TEMP
-0.19
CSI
133 oz of Liquid Chlorine • 12.5%
1.5
FC
1.0
CC
0.34
CSI
11.0
FC
0.34
CSI
48 oz of 31.45% (20º Be) Muriatic Acid
20.5
FC
8.2
pH
52 °F
TEMP
0.34
CSI
Closed pool today.
Closed - blow out skimmers
Recirculate-blow our returns
POF to install replacement heater today.
Vacuumed
K-100 chlorine test kit only reads .5ppm of FC all three times I tested it. Reagent must be bad.
FC is 15 after adding 2 gal of 12.5% LC.
15.0
FC
0.5
CC
-0.05
CSI
128 oz of Liquid Chlorine • 12.5%
128 oz of Liquid Chlorine • 12.5%
0.5
FC
7.5
pH
-0.05
CSI
52 oz of 31.45% (20º Be) Muriatic Acid
128 oz of Liquid Chlorine • 12.5%
0.0
FC
8.2
pH
0.63
CSI
Turned SWCG off
52 oz of 31.45% (20º Be) Muriatic Acid
8.0
FC
0.0
CC
8.2
pH
0.63
CSI
52 oz of 31.45% (20º Be) Muriatic Acid
5.0
FC
0.0
CC
8.2
pH
0.63
CSI
8.5
FC
0.0
CC
8.2
pH
0.63
CSI
35 oz of 31.45% (20º Be) Muriatic Acid
8.0
FC
0.5
CC
7.8
pH
0.24
CSI
1 gal of Liquid Chlorine • 8.25%
7.0
FC
0.0
CC
7.6
pH
0.04
CSI
10.5
FC
0.0
CC
8.2
pH
0.63
CSI
7.8
pH
130
TA
0.24
CSI
Turned SWCG down to 70
55 oz of 31.45% (20º Be) Muriatic Acid
9.5
FC
0.0
CC
8.2
pH
140
TA
300
CH
70
CYA
3200
SALT
85 °F
TEMP
0.67
CSI
45 oz of 31.45% (20º Be) Muriatic Acid
7.0
FC
0.5
CC
8.2
pH
0.51
CSI
45 oz of 31.45% (20º Be) Muriatic Acid
8.5
FC
0.0
CC
8.2
pH
0.51
CSI
7.5
FC
0.5
CC
7.8
pH
0.12
CSI
8.5
FC
1.0
CC
7.8
pH
70
CYA
0.12
CSI
Heavy use today, and sunny all day. Only lost 1 ppm chlorine. Salt cell is at 70.
10.0
FC
0.49
CSI
Turned SWCG down to 70%.
No sun on pool.
Added water to pool.
11.5
FC
0.49
CSI
Turned SWG down to 80%
45 oz of 31.45% (20º Be) Muriatic Acid
11.5
FC
0.5
CC
8.2
pH
0.49
CSI
9.5
FC
7.8
pH
0.10
CSI
15.0
FC
0.5
CC
-0.09
CSI
Turned SWCG back on 90%
128 oz of Liquid Chlorine • 10%
6.0
FC
0.5
CC
-0.09
CSI
Vacuumed
11.5
FC
0.5
CC
-0.09
CSI
Turned SWCG off to do an OCLT.
11.0
FC
0.5
CC
-0.09
CSI
34 oz of Liquid Chlorine • 10%
9.5
FC
1.0
CC
-0.09
CSI
90 oz of Liquid Chlorine • 10%
7.5
FC
0.5
CC
7.6
pH
-0.09
CSI
8.5
FC
7.5
pH
-0.19
CSI
102 oz of Liquid Chlorine • 10%
Had a few inches of rain overnight and chlorine e held at 7.
Cover open.
Still a little cloudy this morning. Going to raise chlorine to max for 80 cya. (Not slam)
7.0
FC
-0.19
CSI
7.0
FC
-0.19
CSI
Set SWCG to Boost for 24 hr
9.0
FC
0.0
CC
7.5
pH
80
CYA
3100
SALT
85 °F
TEMP
-0.19
CSI
153 oz of Liquid Chlorine • 10%
4.0
FC
0.5
CC
7.3
pH
-0.35
CSI
12.5
FC
0.13
CSI
6.5
FC
0.0
CC
7.8
pH
0.13
CSI
9.5
FC
0.5
CC
7.8
pH
0.13
CSI
8.0
FC
-0.45
CSI
13.5
FC
0.5
CC
-0.45
CSI
14.5
FC
-0.45
CSI
22.0
FC
-0.45
CSI
24.0
FC
-0.45
CSI
3.0
FC
0.0
CC
7.2
pH
88 °F
TEMP
-0.45
CSI
51 oz of Liquid Chlorine • 10%
6.0
FC
0.5
CC
7.5
pH
110
TA
275
CH
70
CYA
3580
SALT
88 °F
TEMP
-0.16
CSI
6.0
FC
-0.30
CSI
Bumping SWG to 40% and tipping off pool water level.
6.5
FC
-0.30
CSI
Only had 56 oz of 12%.
Should raise FC by 2.7ppm.
From 5 to 7.7ppm FC.
SWG still at 20%.
To increase chlorine from 5-8.
64 oz of Liquid Chlorine • 12%
5.0
FC
-0.30
CSI
Increased SWG from 10 to 20%
5.0
FC
0.5
CC
7.5
pH
-0.30
CSI
14.0
FC
0.5
CC
-0.30
CSI
15.0
FC
0.0
CC
-0.30
CSI
22.0
FC
0.0
CC
-0.30
CSI
28.0
FC
-0.30
CSI
Turned heater off.
Water temp 73.
576 oz of Liquid Chlorine • 10%
Passed OCLT.
Lost .5 FC
Barely have .5 cc
Water still dull
Going to leave cover open today and bring FC up to SLAM level.