Bullfrog A6L Select Hot Tub

Volume: 335 Gallons
Build Type: Fiberglass
10 oz of Liquid Chlorine • 4%
I just realized my Pool Chlorine is more deteriorated than I had calculated. I adjusted Poolmath bleach % until 9.5 oz predicted the +10 FC that that dose yielded for me. I revised the last two weeks worth of Bleach %'s to 4%.
15.0
FC
9.5 oz of Liquid Chlorine • 4%
5.0
FC
65
TA
5.6
FC
7.5
pH
70
TA
10.4
FC
7.5
pH
70
TA
14.2
FC
7.4
pH
80
TA
1.2 oz of Dichlor
With FC at 0.0 ppm and water was cloudy. I am trying to raise CYA from < 1 ppm, hoping to get to CYA of 30 eventually. I am going away for 5 days... I added 1.2 oz of Dichlor to raise FC from 0 to 16 (per P'Math). At 12:50pm, TA jumped from 50 to 80!??? FC 14.2, pH 7.4
0.0
FC
4.4
FC
7.4
pH
50
TA
1.0
FC
7.4
pH
50
TA
2.0
FC
7.3
pH
55
TA
0.5 oz of 31.45% (20º Be) Muriatic Acid
4.2
FC
7.6
pH
0.2 oz of 31.45% (20º Be) Muriatic Acid
1.8 oz of Liquid Chlorine • 4%
CC tested 0.6 ppm
0.4
FC
7.6
pH
60
TA
1 oz of Liquid Chlorine • 7.5%
30 min B'Ld.
4.4
FC
1 oz of Liquid Chlorine • 4%
Two people 30 min., no shower before. One w/ 'unrinsed detergent suit'. (1 hr. B'load.) For first time, tub had larger 'bubbles' (I assume from deterg.) and smaller 'foam' (I assume from bather's sweat, etc.) Foam scooped out for 5-8 mins.
CC Comb. Chlor. 0.6 ppm
4.4
FC
2 oz of Liquid Chlorine • 4%
CC- Comb. Chlorine 1 ppm
2.0
FC
7.6
pH
60
TA
** 1.5 oz Awesome wkly dose. 30 min B'Ld
2 oz of Liquid Chlorine • 4%
.5 hr. B'Load
3 oz of Liquid Chlorine • 4%
.75 hr. B'Load
2.5 oz of Liquid Chlorine • 4%
2.2
FC
7.5
pH
3 oz of Liquid Chlorine • 4%
1.25 hr. B'Load
4.2
FC
7.5
pH
55
TA
6.6
FC
7.6
pH
60
TA
0.65 oz of 15.7% (10º Be) Muriatic Acid
2 oz of Liquid Chlorine • 7.5%
1.0
FC
7.7
pH
60
TA
3 oz of Liquid Chlorine • 7.5%
40 min B'Load
2.8
FC
7.4
pH
60
TA
0.75 oz of 31.45% (20º Be) Muriatic Acid
4.5
FC
7.7
pH
60
TA
250
CH
1 oz of Liquid Chlorine • 7.5%
0.34 oz of 31.45% (20º Be) Muriatic Acid
5.6
FC
7.7
pH
4.5 oz of Liquid Chlorine • 8%
1.0
FC
1 oz of Liquid Chlorine • 8%
15.0
FC
7.9
pH
70
TA
0.6 oz of 31.45% (20º Be) Muriatic Acid
7.5 oz of Liquid Chlorine • 8%
0.4
FC
7.7
pH
65
TA
4.2
FC
7.7
pH
60
TA
1 hr. bthr load
5.8
FC
7.7
pH
60
TA
2.6 oz of Liquid Chlorine • 8%
30 min. bather load
3.4
FC
7.4
pH
65
TA
1.2 oz of 31.45% (20º Be) Muriatic Acid
30 min. bather load
3.8
FC
8.0
pH
70
TA
6.0
FC
8.1
pH
1.5 oz of 31.45% (20º Be) Muriatic Acid
0.8 oz of 31.45% (20º Be) Muriatic Acid
6.6
FC
8.5
pH
110
TA
0.4 oz of Dichlor
0.8
FC
9.0
pH
100
TA
1.5 oz of 31.45% (20º Be) Muriatic Acid
2.3 oz of 15.7% (10º Be) Muriatic Acid
1.4 oz of 15.7% (10º Be) Muriatic Acid
1.1 oz of 15.7% (10º Be) Muriatic Acid
I forgot to test pH & TA 'AFTER' adding the Dichlor & Bkg Soda. I did not know Borax would lock pH where it was (Way above 8 bright red) when Borax was added. :o0
9.0
pH
Decided to add Borax. PoolMath said to add 20 oz (by wt.) or 19 oz. (by volume). BUT when the measuring cup on the scale got to 19 oz of Volume, the weight was only 13 oz. WTH? I added this 19 oz vol./ 13 oz wt. to the tub.
Baking Soda to raise TA 40 to 50
0.8 oz of Baking Soda
0.4 oz of Dichlor
0.6
FC
7.5
pH
+ 1.5 oz Aqua Clarity Wkly dose
4.4
FC
7.5
pH
40
TA
0.35 oz of Dichlor
End of 1/2 hour bather load.
3.2
FC
5.8
FC
7.4
pH
0.3 oz of Dichlor
2.2
FC
6.0
FC
0.2 oz of Dichlor
3.2
FC
7.4
pH
6.4
FC
7.5
pH
45
TA
Added 3.5 oz (wt.) Dichlor, a little less than 2 Tsp.
2.0
FC
7.4
pH
45
TA
250
CH
10
CYA
6.5
FC
11.0
FC
7.6
pH
50
TA
10
CYA
Nitro said on fresh fill, after balanced, shock w/ Dichlor to 10 ppm. PoolMath Calc. said to add .8 oz (wt.) to get to 10 ppm. (Dichlor container said to add 3.5 Tspn 6.7 oz "for shock".)
0.8 oz of Dichlor
0.0
FC
7.4
pH
50
TA
350
CH
0
CYA
3 oz of 15.7% (10º Be) Muriatic Acid
0.0
FC
8.2
pH
75
TA
350
CH
0
CYA
5 oz of 15.7% (10º Be) Muriatic Acid
0.0
FC
8.2
pH
100
TA
350
CH
0
CYA
0.0
FC
6.8
pH
110
TA
350
CH
0
CYA
18 oz of 15.7% (10º Be) Muriatic Acid
0.0
FC
8.6
pH
225
TA
350
CH
0
CYA
0.0
FC
7.4
pH
250
TA
350
CH
0
CYA
12 oz of 15.7% (10º Be) Muriatic Acid
0.0
FC
6.8
pH
275
TA
350
CH
0
CYA
0.0
FC
7.8
pH
275
TA
350
CH
0
CYA