Pool

Volume: 72500 Liters
Build Type: Vinyl
3.8
FC
0.0
CC
7.9
pH
74 °F
TEMP
0.21
CSI
Started filling pool. 1 3/4” under skimmer line. Using skimmer line only causes pump to run dry.
Pool water level is 1 1/4” below skimmer line. 2” loss since last checked.
Pump off all night. Measured from skimmer 3/4” above mark. 1/2” loss over night.
4.6
FC
0.2
CC
7.6
pH
140
TA
70
CYA
71 °F
TEMP
-0.12
CSI
Turned pool pump off. Looks like water and bucket are about equal.
Stopped filling at 1 1/4” above line on skimmer. Reset bucket test. Water heater at 75.
Lost 7/8” of water since test started. Started to refill. Water was 1 1/4” below line on skimmer.
850 g of Dry Stabilizer
4.4
FC
0.2
CC
7.5
pH
130
TA
270
CH
60
CYA
3800
SALT
76 °F
TEMP
-0.19
CSI
Restarted bucket leak test on skimmer and return. Bucket was almost half an inch higher.
82 °F
TEMP
0.03
CSI
Salt cell reading 3300 avg.
1050 g of Dry Stabilizer
Started bucket leak test, skimmer and returns only.
1000 g of Dry Stabilizer
Salt cell reading 3400 avg
Salt cell reading 3300 avg.
1000 g of Dry Stabilizer
3000 mL of 31.45% (20º Be) Muriatic Acid
20 kg of Salt
3.8
FC
0.0
CC
7.6
pH
140
TA
73 °F
TEMP
-0.05
CSI
Vacuumed Brushed
Filter Pressure:10
72 °F
TEMP
-0.55
CSI
Salt cell now reading 3200 avg. Turned down from 33% to 25%.
Brushed
7.0
pH
-0.54
CSI
4000 mL of 31.45% (20º Be) Muriatic Acid
Salt cell is reading 3100 avg and test is showing 3800.
Vacuumed Brushed
Filter Pressure:10
2.6
FC
0.0
CC
8.0
pH
170
TA
270
CH
3800
SALT
75 °F
TEMP
0.45
CSI
40 kg of Salt
40 kg of Salt
7.0
pH
77 °F
TEMP
-0.40
CSI
4000 mL of 31.45% (20º Be) Muriatic Acid
5.4
FC
0.0
CC
7.6
pH
200
TA
270
CH
3000
SALT
76 °F
TEMP
0.18
CSI
4.8
FC
0.0
CC
7.2
pH
200
TA
270
CH
3000
SALT
76 °F
TEMP
-0.22
CSI
80 kg of Salt
3000 mL of 31.45% (20º Be) Muriatic Acid
6.0
FC
0.0
CC
7.4
pH
200
TA
250
CH
25
CYA
2000
SALT
75 °F
TEMP
-0.01
CSI
77 °F
TEMP
0.86
CSI
40 kg of Salt
80 kg of Salt
Vacuumed Brushed
Filter Pressure:10
5000 mL of 31.45% (20º Be) Muriatic Acid
0.8
FC
0.2
CC
8.0
pH
240
TA
270
CH
68 °F
TEMP
0.78
CSI
1250 g of Dry Stabilizer
3000 mL of 31.45% (20º Be) Muriatic Acid
2.0
FC
0.0
CC
7.8
pH
280
TA
300
CH
5
CYA
500
SALT
54 °F
TEMP
0.55
CSI
Opened Pool Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:10
2000 mL of 31.45% (20º Be) Muriatic Acid
Vacuumed Brushed
Filter Pressure:10
3200
SALT
0.07
CSI
7.0
FC
0.0
CC
7.8
pH
81 °F
TEMP
0.04
CSI
2000 mL of 31.45% (20º Be) Muriatic Acid
Added two packs of multi-shock after today’s pool party. Water actually looked pretty good. Slight haze.
1000 g of pH Down / Dry Acid
6.2
FC
0.0
CC
7.4
pH
100
TA
300
CH
65
CYA
4000
SALT
82 °F
TEMP
-0.34
CSI
2500 mL of 31.45% (20º Be) Muriatic Acid
1000 g of pH Down / Dry Acid
60 kg of Salt
7.0
pH
90
TA
83 °F
TEMP
-0.87
CSI
1000 mL of 31.45% (20º Be) Muriatic Acid
7.2
pH
105
TA
84 °F
TEMP
-0.61
CSI
1000 mL of 31.45% (20º Be) Muriatic Acid
4.2
FC
0.0
CC
7.4
pH
110
TA
3600
SALT
84 °F
TEMP
-0.39
CSI
500 g of Dry Stabilizer
2000 mL of 31.45% (20º Be) Muriatic Acid
5.2
FC
0.0
CC
7.8
pH
100
TA
219
CH
63
CYA
87 °F
TEMP
-0.03
CSI
750 g of pH Down / Dry Acid
Vacuumed Brushed
5.8
FC
0.0
CC
7.8
pH
115
TA
230
CH
3600
SALT
85 °F
TEMP
0.06
CSI
Turned SWCG up to 40 from 30.
750 g of pH Down / Dry Acid
750 g of pH Down / Dry Acid
900ml stain and scale control (few metal deposit spots on liner that don’t remove with scrubbing).
Vacuumed Brushed
Added cover free dose and a clarifier to see if anything is suspended in the water. Will vacuum tomorrow and then clean the filter this week.
500 g of pH Down / Dry Acid
Vacuumed Brushed
4.8
FC
0.0
CC
7.8
pH
110
TA
230
CH
3400
SALT
87 °F
TEMP
0.07
CSI
750 g of pH Down / Dry Acid
500 g of pH Down / Dry Acid
1100 g of pH Down / Dry Acid
2.8
FC
0.0
CC
8.0
pH
110
TA
3600
SALT
88 °F
TEMP
0.25
CSI
Vacuumed Brushed
4.8
FC
0.0
CC
7.4
pH
110
TA
86 °F
TEMP
-0.33
CSI
1000 g of pH Down / Dry Acid
Vacuumed Brushed
7.0
FC
0.0
CC
7.5
pH
100
TA
3200
SALT
80 °F
TEMP
-0.35
CSI
Added two packages of multishock.
1750 g of pH Down / Dry Acid
1010 g of pH Down / Dry Acid
D&D test results
3.2
FC
0.0
CC
7.9
pH
100
TA
221
CH
56
CYA
2900
SALT
85 °F
TEMP
0.10
CSI
3.2
FC
0.0
CC
7.2
pH
115
TA
230
CH
3200
SALT
85 °F
TEMP
-0.50
CSI
Filled pool to 1/8th below black line at stairs
7.2
pH
100
TA
85 °F
TEMP
-0.56
CSI
700 g of Dry Stabilizer
1750 mL of 31.45% (20º Be) Muriatic Acid
Test by D&D
3.9
FC
0.0
CC
7.8
pH
100
TA
228
CH
54
CYA
3000
SALT
87 °F
TEMP
0.03
CSI
Vacuumed Brushed
4.6
FC
0.0
CC
7.6
pH
120
TA
3400
SALT
85 °F
TEMP
-0.11
CSI
1000 mL of 31.45% (20º Be) Muriatic Acid
Salt tests all over. Drop kit saying 3800, DD saying 3100 and salt cell sensing 3000.
4.2
FC
0.2
CC
7.9
pH
105
TA
3800
SALT
88 °F
TEMP
0.13
CSI
Added package of multi-shock this morning
Last test from D&D
5.2
FC
0.0
CC
7.4
pH
86
TA
225
CH
57
CYA
3000
SALT
72 °F
TEMP
-0.57
CSI
1000 mL of 31.45% (20º Be) Muriatic Acid
7.5
pH
105
TA
72 °F
TEMP
-0.39
CSI
7.0
pH
-0.76
CSI
500 mL of 31.45% (20º Be) Muriatic Acid
7.2
pH
-0.57
CSI
1600 mL of 31.45% (20º Be) Muriatic Acid
2000 g of pH Down / Dry Acid
4.4
FC
0.0
CC
8.1
pH
130
TA
3600
SALT
72 °F
TEMP
0.31
CSI
Vacuumed Brushed
Vacuumed Brushed
1004 g of pH Down / Dry Acid
3.5
FC
0.0
CC
7.4
pH
140
TA
3500
SALT
81 °F
TEMP
-0.26
CSI
2500 mL of 31.45% (20º Be) Muriatic Acid
3.3
FC
0.1
CC
8.1
pH
137
TA
230
CH
61
CYA
3100
SALT
80 °F
TEMP
0.42
CSI
Vacuumed Brushed
3000 mL of 31.45% (20º Be) Muriatic Acid
2.4
FC
0.0
CC
7.8
pH
134
TA
197
CH
59
CYA
3300
SALT
87 °F
TEMP
0.10
CSI
D&D
7.4
pH
86 °F
TEMP
-0.17
CSI
1500 mL of 31.45% (20º Be) Muriatic Acid
500 mL of 31.45% (20º Be) Muriatic Acid
3000 mL of Liquid Stabilizer
Vacuumed Brushed
3.0
FC
0.0
CC
7.8
pH
150
TA
220
CH
35
CYA
3400
SALT
80 °F
TEMP
0.16
CSI
Vacuumed Brushed
Added package of multi shock after day with family over.
Previous test from D&D pools
3.7
FC
0.0
CC
7.4
pH
103
TA
145
CH
34
CYA
3000
SALT
83 °F
TEMP
-0.53
CSI
6.8
FC
0.2
CC
7.5
pH
150
TA
80 °F
TEMP
-0.29
CSI
500 mL of 31.45% (20º Be) Muriatic Acid
4.8
FC
0.2
CC
7.6
pH
85 °F
TEMP
0.03
CSI
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:10
1000 mL of Liquid Stabilizer
Vacuumed Brushed
4.8
FC
0.2
CC
8.0
pH
160
TA
220
CH
40
CYA
3600
SALT
80 °F
TEMP
0.38
CSI
2 L of 31.45% (20º Be) Muriatic Acid
2 L of 31.45% (20º Be) Muriatic Acid
6.5
FC
0.0
CC
8.0
pH
150
TA
212
CH
48
CYA
3200
SALT
75 °F
TEMP
0.29
CSI
4.6
FC
0.2
CC
7.4
pH
170
TA
220
CH
44
CYA
3400
SALT
84 °F
TEMP
-0.15
CSI
585 g of Dry Stabilizer
20 kg of Salt
405 g of Dry Stabilizer
20 kg of Salt
5.0
FC
0.5
CC
7.5
pH
160
TA
190
CH
30
CYA
3000
SALT
76 °F
TEMP
-0.17
CSI
Vacuumed Brushed
Filter Pressure:11
300 g of Dry Stabilizer
3.6 L of Liquid Chlorine • 10.3%
60 kg of Salt
5.0
FC
0.0
CC
7.2
pH
165
TA
190
CH
20
CYA
2000
SALT
72 °F
TEMP
-0.43
CSI
5.5
FC
0.0
CC
7.1
pH
160
TA
15
CYA
73 °F
TEMP
-0.54
CSI
250 g of Dry Stabilizer
350 g of Dry Stabilizer
Turned heater on to 75
7.8
FC
0.5
CC
7.1
pH
167
TA
186
CH
15
CYA
2000
SALT
64 °F
TEMP
-0.61
CSI
Results from D&D automated testing
8.0
FC
0.5
CC
7.1
pH
160
TA
230
CH
15
CYA
2400
SALT
63 °F
TEMP
-0.56
CSI
9.0
FC
9.5
CC
7.1
pH
160
TA
63 °F
TEMP
-0.63
CSI
1.75 kg of Dry Stabilizer
7.2 L of Liquid Chlorine • 10.3%
4 L of 31.45% (20º Be) Muriatic Acid
0.0
FC
7.4
pH
180
TA
63 °F
TEMP
-0.18
CSI
4 L of 31.45% (20º Be) Muriatic Acid
5.0
FC
1.0
CC
7.8
pH
200
TA
54 °F
TEMP
0.18
CSI
7.0
FC
0.5
CC
7.8
pH
210
TA
59 °F
TEMP
0.25
CSI
7.2 L of Liquid Chlorine • 10.3%
7.4
pH
200
TA
59 °F
TEMP
-0.17
CSI
7.0
pH
190
TA
53 °F
TEMP
-0.66
CSI
0.0
FC
7.4
pH
210
TA
230
CH
0
CYA
2000
SALT
53 °F
TEMP
-0.21
CSI
Switched to Taylor kit
0.0
FC
7.6
pH
210
TA
53 °F
TEMP
4 L of 31.45% (20º Be) Muriatic Acid
0.0
FC
7.4
pH
300
TA
53 °F
TEMP
1.5
FC
7.4
pH
280
TA
2 L of 31.45% (20º Be) Muriatic Acid
300
SALT
3.0
FC
7.2
pH
310
TA
53 °F
TEMP
7.4
pH
290
TA
7.2 L of Liquid Chlorine • 10.3%
2 L of 31.45% (20º Be) Muriatic Acid
Vacuumed Brushed Cleaned Filter
Filter Pressure:11
7.4
pH
280
TA
2 L of 31.45% (20º Be) Muriatic Acid
7.8
pH
340
TA
2 L of 31.45% (20º Be) Muriatic Acid
8.2
pH
350
TA
2 L of 31.45% (20º Be) Muriatic Acid
8.4
pH
350
TA
2 L of 31.45% (20º Be) Muriatic Acid
Opened Pool Vacuumed Brushed Cleaned Filter
Filter Pressure:10