RookiePool

Volume: 35900 Liters
Build Type: Fiberglass
8.0
FC
19 °C
TEMP
-0.26
CSI
Vacuumed Brushed
7.5
FC
0.0
CC
7.8
pH
19 °C
TEMP
-0.24
CSI
set swg to 40% output. approx 2.2fc generation
turned off chlorine generator night of 23rd April. 2.5 FC consumed in 24hrs reduced pump run time to 8 hrs
6.0
FC
18 °C
TEMP
-0.28
CSI
8.5
FC
21 °C
TEMP
-0.21
CSI
Vacuumed Brushed Cleaned Filter
Filter Pressure:10
Vacuumed Brushed Cleaned Filter
Filter Pressure:9
300 mL of 14.5% Muriatic Acid
8.5
FC
0.0
CC
7.8
pH
90
TA
200
CH
40
CYA
3400
SALT
26 °C
TEMP
-0.13
CSI
Vacuumed Brushed
Filter Pressure:15
10.0
FC
0.0
CC
26 °C
TEMP
-0.26
CSI
Vacuumed Brushed
8.5
FC
29 °C
TEMP
-0.23
CSI
Vacuumed Brushed
300 mL of 14.5% Muriatic Acid
Vacuumed Brushed
7.0
FC
7.8
pH
50
CYA
-0.20
CSI
350 mL of 14.5% Muriatic Acid
6.0
FC
7.8
pH
-0.20
CSI
Vacuumed Brushed Cleaned Filter
10.0
FC
30 °C
TEMP
-0.40
CSI
8.0
FC
31 °C
TEMP
-0.38
CSI
Vacuumed Brushed
Vacuumed Brushed
Filter Pressure:13
NYE party yesterday. 9 kids plus odd adult swimming for many hours. lots of paper debris into pool. pool was getting a bit cloudy by conclusion. left pump & swg generator running overnight. pool clear and.numbers as per.this.mornings test. added last of on hand CYA. need to get filter cleaning chems and treat cartridge.
290 g of Dry Stabilizer
7.5
FC
80
TA
175
CH
3200
SALT
29 °C
TEMP
-0.43
CSI
7.0
FC
7.6
pH
50
CYA
31 °C
TEMP
-0.40
CSI
Vacuumed Brushed
9.0
FC
31 °C
TEMP
-0.40
CSI
800 mL of Liquid Chlorine • 8%
7.5
FC
7.6
pH
-0.44
CSI
kids did not take SWG out of cover mode while I was away but had cover off. Calculated bleach strength after addition and retest of FC change.
2000 mL of Liquid Chlorine • 8%
2.5
FC
-0.35
CSI
Vacuumed Brushed
10.5
FC
-0.35
CSI
Vacuumed Brushed
9.0
FC
7.7
pH
29 °C
TEMP
-0.35
CSI
8.0
FC
30 °C
TEMP
-0.43
CSI
Vacuumed Brushed
700 g of Dry Stabilizer
7.0
FC
7.6
pH
70
TA
200
CH
50
CYA
-0.41
CSI
turned SWG up to 10.5 hours per day run time
6.0
FC
30 °C
TEMP
-0.53
CSI
5.5
FC
30 °C
TEMP
-0.54
CSI
Vacuumed Brushed
7.0
FC
0.0
CC
7.6
pH
28 °C
TEMP
-0.57
CSI
Cleaned Filter
Filter Pressure:8
need to clean pump basket and filter
Vacuumed Brushed
Filter Pressure:11
Vacuumed Brushed
7.5
FC
26 °C
TEMP
-0.60
CSI
Vacuumed Brushed
7.5
FC
0.0
CC
7.6
pH
70
TA
175
CH
26 °C
TEMP
-0.60
CSI
400 mL of 14.5% Muriatic Acid
turned SWG to 80%
6.5
FC
29 °C
TEMP
-0.54
CSI
Vacuumed Brushed
950 mL of Liquid Chlorine • 12.5%
5.5
FC
60
TA
26 °C
TEMP
-0.59
CSI
turn SWG up to 50%
5.5
FC
0.0
CC
27 °C
TEMP
-0.56
CSI
Vacuumed Brushed
7.0
FC
7.8
pH
20 °C
TEMP
-0.67
CSI
8.5
FC
0.0
CC
21 °C
TEMP
-0.84
CSI
7.5
FC
7.6
pH
21 °C
TEMP
-0.84
CSI
Vacuumed Brushed
8.5
FC
0.0
CC
22 °C
TEMP
-0.82
CSI
9.5
FC
0.0
CC
7.6
pH
21 °C
TEMP
-0.84
CSI
Vacuumed Brushed
Filter Pressure:9
8.5
FC
20 °C
TEMP
-1.05
CSI
7.4
pH
60
TA
-1.03
CSI
set dose pump to 630ml. ran 57 seconds. reset dose pump to 550ml. ran 7 mins 20 sec
630 mL of 14.5% Muriatic Acid
7.5
FC
0.0
CC
7.8
pH
70
TA
150
CH
70
CYA
20 °C
TEMP
-0.56
CSI
Vacuumed Brushed
Filter Pressure:9.5
set SWG to 30% cover off as kids swimming daily.
7.0
FC
19 °C
TEMP
-0.77
CSI
Vacuumed Brushed
Filter Pressure:8
took cover off for daylight 23rd August and set SWG to 20%. put cover back on and activated cover mode again. kids swim 23 24 25 August. less than 1 hr
7.5
FC
0.5
CC
7.6
pH
19 °C
TEMP
-0.77
CSI
8.5
FC
0.0
CC
18 °C
TEMP
-0.78
CSI
put on pool blanket. set SWG to cover on mode start temp 15C
Vacuumed Brushed
Filter Pressure:8
8.0
FC
0.0
CC
7.6
pH
70
CYA
16 °C
TEMP
-0.82
CSI
SWG turned on to 20%
turned off SWG. running robot 2 hr floor to mix and dissolve Chems after brushing in
1000 g of Dry Stabilizer
20 kg of Salt
40
CYA
-0.56
CSI
Vacuumed Brushed
SWG turned back to 20%. pump run time left 8 hrs
9.5
FC
0.0
CC
7.8
pH
16 °C
TEMP
-0.59
CSI
Vacuumed Brushed
Filter Pressure:9
dosing pump ran 5 mins 30. set SWG to 30%. suspect CYA down as per salt
400 mL of 14.5% Muriatic Acid
5.5
FC
0.5
CC
7.8
pH
70
TA
150
CH
3200
SALT
15 °C
TEMP
-0.60
CSI
dosing pump ran 4mins30sec approx
300 mL of 14.5% Muriatic Acid
Vacuumed Brushed
Filter Pressure:10
6.5
FC
0.5
CC
7.8
pH
16 °C
TEMP
-0.57
CSI
7.0
FC
0.0
CC
7.8
pH
15 °C
TEMP
-0.59
CSI
Vacuumed Brushed
Filter Pressure:8
300 mL of 14.5% Muriatic Acid
7.0
FC
0.0
CC
7.8
pH
16 °C
TEMP
-0.57
CSI
7.0
FC
-0.81
CSI
5.5
FC
-0.81
CSI
5.5
FC
0.0
CC
7.6
pH
70
TA
175
CH
50
CYA
13 °C
TEMP
-0.81
CSI
Vacuumed Brushed
Filter Pressure:9
turned SWG to 20% pumped 2-3" to waste
5.0
FC
0.0
CC
7.8
pH
14 °C
TEMP
-0.69
CSI
6.0
FC
0.0
CC
7.8
pH
15 °C
TEMP
-0.66
CSI
Vacuumed Brushed
5.5
FC
0.0
CC
7.6
pH
60
TA
175
CH
15 °C
TEMP
-0.85
CSI
Vacuumed Brushed
Filter Pressure:8
7.5
FC
14 °C
TEMP
-0.65
CSI
pumped another 1-2" to waste around lunch time and set SWG to 40%> FC checked and SWG reset to 10%
7.5
FC
0.0
CC
7.6
pH
15 °C
TEMP
-0.63
CSI
big storm this afternoon/evening. checked pool before bed and almost overflowing. found some plumbing pieces and pumped 4-5" to waste. review in the morning
7.5
pH
80
TA
16 °C
TEMP
-0.73
CSI
dose pump ran 5 mins 20 seconds
400 mL of 14.5% Muriatic Acid
Vacuumed Brushed
dose pump ran 50 seconds
400 mL of 14.5% Muriatic Acid
7.5
FC
16 °C
TEMP
-0.57
CSI
turned SWG down to 10% set pump to run at 1900rpm
9.5
FC
0.0
CC
7.6
pH
90
TA
16 °C
TEMP
-0.55
CSI
skimming performance seems to be marginal at 1300rpm. debris accumulating on edge of pool surface
added 400mL MA via doser. Ran for 5 mins 30 secs to dose.
400 mL of 14.5% Muriatic Acid
turned SWG to 20% output. pump run time 8 hours. 1300rpm speed
8.0
FC
0.0
CC
7.6
pH
100
TA
200
CH
50
CYA
15 °C
TEMP
-0.51
CSI
400 mL of 14.5% Muriatic Acid
set doser to add 400mL MA. pump ran for approx 30 seconds.
585 g of Dry Stabilizer
Vacuumed Brushed
7.0
FC
16 °C
TEMP
-0.53
CSI
7.0
FC
7.6
pH
16 °C
TEMP
-0.53
CSI
7.0
FC
0.0
CC
7.6
pH
90
TA
200
CH
40
CYA
4400
SALT
17 °C
TEMP
-0.53
CSI
Brushed
4000 g of Calcium Chloride
300 mL of 14.5% Muriatic Acid
turned SWG down to 30%. pump run time 8 hours/day
Vacuumed
7.0
FC
0.0
CC
7.8
pH
18 °C
TEMP
-0.60
CSI
this is not a test NB: testing
turned SWG up to 40%. pump run time 8 hours/day
5.5
FC
0.0
CC
7.6
pH
80
TA
125
CH
50
CYA
4400
SALT
17 °C
TEMP
-0.82
CSI

RookiePool0

Volume: 136274 Liters
Build Type: Fiberglass
6.5
FC
0.0
CC
7.6
pH
80
TA
50
CYA
18 °F
TEMP
-0.77
CSI
6.5
FC
0.0
CC
-0.62
CSI
4.0
FC
7.6
pH
18 °F
TEMP
-0.62
CSI
3800
SALT
-0.62
CSI
5.5
FC
0.0
CC
7.6
pH
125
CH
17 °F
TEMP
-0.62
CSI
5.0
FC
7.6
pH
18 °F
TEMP
-0.62
CSI
4.5
FC
7.8
pH
-0.42
CSI
4.5
FC
7.8
pH
17 °F
TEMP
-0.42
CSI
7.8
pH
-0.43
CSI
4.0
FC
7.8
pH
3600
SALT
16 °F
TEMP
-0.43
CSI
4.0
FC
17 °F
TEMP
-0.39
CSI
4.0
FC
0.0
CC
7.8
pH
100
TA
125
CH
30
CYA
2600
SALT
3.0
FC
4.0
FC
0.0
CC
3.0
FC
4.0
FC
0.0
CC
4.5
FC
4.5
FC
3.0
FC
0.0
CC
7.8
pH
40
CYA
0.5
FC
0.0
CC
0.0
FC
0.5
CC
4.0
FC
0.0
CC
1.0
FC
0.5
CC
80
TA
0.0
FC
0.0
CC
7.8
pH
100
TA
125
CH
0
CYA
2.0
FC
7.6
pH
90
TA
0
CYA
0.1
FC
7.6
pH
0
CYA
0.5
FC
7.6
pH
90
TA
0
CYA
3.0
FC
7.6
pH
90
TA
0
CYA
3.0
FC
7.4
pH
90
TA
0
CYA
3.0
FC
7.6
pH
100
TA
0
CYA
1.0
FC
7.6
pH
0
CYA
3.0
FC
7.6
pH
100
TA
0
CYA
0.5
FC
7.6
pH
80
TA
0
CYA
0.5
FC
7.2
pH