Glade Road

Volume: 18000 Gallons
Build Type: Vinyl
Closing today- water temp 69 degrees Salt reading Taylor kit 3500 Salt per acurite control box 3700
8.5
FC
0.5
CC
7.6
pH
70
TA
150
CH
60
CYA
3500
SALT
60 °F
TEMP
-0.82
CSI
8.5
FC
0.0
CC
7.6
pH
70
TA
62 °F
TEMP
-0.84
CSI
6.0
FC
7.6
pH
68 °F
TEMP
-0.77
CSI
7.5
FC
0.0
CC
7.6
pH
70
CYA
3600
SALT
64 °F
TEMP
-0.82
CSI
Moved SWG down to 10 from 15
8.0
FC
0.0
CC
7.5
pH
70
TA
70
CYA
62 °F
TEMP
-0.94
CSI
Received over 3.5” of rain Friday & Saturday
7.0
FC
63 °F
TEMP
-1.01
CSI
Increase SWG to 15 from 5
6.5
FC
0.0
CC
-1.03
CSI
7.0
FC
0.0
CC
7.4
pH
70
TA
70
CYA
62 °F
TEMP
-1.03
CSI
TA added about 3.5lbs of sodium bicarbonate to get ta to around 60 CYA added 2lb 10 oz dry acid (mega stabilizer) to get to around 60 cya
40 oz of Dry Stabilizer
48 oz of Baking Soda
Backwashed
Filter Pressure:13
turned on SWG to 20 for 1 hour then to 5
6.0
FC
0.0
CC
7.4
pH
50
TA
150
CH
45
CYA
3800
SALT
64 °F
TEMP
-1.14
CSI
8.0
FC
0.0
CC
7.4
pH
55
TA
79 °F
TEMP
-0.91
CSI
Turned off SWG
9.5
FC
0.0
CC
7.4
pH
69 °F
TEMP
-0.95
CSI
9.5
FC
0.0
CC
7.6
pH
70 °F
TEMP
-0.75
CSI
9.5
FC
0.5
CC
7.5
pH
60
TA
60
CYA
3300
SALT
70 °F
TEMP
-0.84
CSI
18 oz of 29% Muriatic Acid
Decreased SWG to 5
13.0
FC
7.8
pH
72 °F
TEMP
-0.54
CSI
-0.75
CSI
9.5
FC
7.4
pH
-0.85
CSI
Increased to 50%
7.5
FC
-0.85
CSI
I Increased SWG to 30% from 5% since fc dropped to 8 from 10 And I’ll be away for 3 days
8.0
FC
0.0
CC
7.4
pH
60
TA
60
CYA
3200
SALT
80 °F
TEMP
-0.85
CSI
10.0
FC
-0.85
CSI
10.0
FC
0.5
CC
80 °F
TEMP
-0.85
CSI
10.5
FC
0.5
CC
7.4
pH
60
TA
60
CYA
3200
SALT
82 °F
TEMP
-0.84
CSI
10.5
FC
-1.18
CSI
12.0
FC
0.5
CC
-1.18
CSI
12.0
FC
84 °F
TEMP
-1.18
CSI
12.5
FC
0.5
CC
60
TA
55
CYA
82 °F
TEMP
-1.20
CSI
14.5
FC
80 °F
TEMP
-1.13
CSI
14.0
FC
0.5
CC
70
TA
170
CH
3600
SALT
82 °F
TEMP
-1.12
CSI
16.0
FC
82 °F
TEMP
-1.20
CSI
16.5
FC
80 °F
TEMP
-1.21
CSI
17.5
FC
0.5
CC
55
CYA
3600
SALT
82 °F
TEMP
-1.20
CSI
Vacuumed
Filter Pressure:13.3
40 lbs of Salt
The OCLT test #2 has passed
20.5
FC
55
CYA
3000
SALT
74 °F
TEMP
-1.23
CSI
Oclt test #2. 42 drops fc 21
21.0
FC
-1.18
CSI
27.5
FC
-1.18
CSI
OCLT test #2 =. 56 or 57 = fc 28 28.5 test #1. 52 or 53 drops. fc 26 or 26.5
28.0
FC
-1.18
CSI
Added 160 salt should raise salt lol by ~1060 ppm to about 3200
160 lbs of Salt
26.0
FC
0.5
CC
52
CYA
2200
SALT
75 °F
TEMP
-1.18
CSI
26.5
FC
0.5
CC
55
CYA
72 °F
TEMP
-1.20
CSI
Slam target is 24
18 oz of Liquid Chlorine • 12.5%
23.0
FC
60
CYA
-1.20
CSI
Vacuumed Brushed
Filter Pressure:13.3
22.0
FC
0.5
CC
50
CYA
74 °F
TEMP
-1.17
CSI
-1.17
CSI
26.0
FC
-1.21
CSI
28.5
FC
-1.21
CSI
Started slam with 319 oz of lc Stopped adding salt at recommendation of forum. If I have to let more water out I could lose the salt that I add now.
319 oz of Liquid Chlorine • 12.5%
40 lbs of Salt
Turned off SWG adding salt and performing a SLAM
6.5
FC
0.5
CC
7.0
pH
60
TA
170
CH
60
CYA
2100
SALT
72 °F
TEMP
-1.21
CSI
Came home pool is green . Was clear this morning. SWG instant read salt 2400 I read using k-1766 about 2100
Took pool down to 18” in shallow end. I guestamte that to be 24”. Which is about 33% of the average depth (6ft). So that should lower CYA ~33% to about 67% to 70% For purposes of Slamming the pool
9.0
FC
0.5
CC
7.5
pH
90
CYA
3400
SALT
72 °F
TEMP
-0.58
CSI
Per Taylor salt test 3200 vs SWG 3500 Did nothing test again tomorrow Since SWG is happy
10.5
FC
7.5
pH
3200
SALT
75 °F
TEMP
-0.53
CSI
Increase SWG to 30%. Since fc went down to 9.5 from 11.5 over two days
9.5
FC
0.5
CC
7.4
pH
75
TA
80
CYA
3600
SALT
75 °F
TEMP
-0.64
CSI
Lowered SWG to 20% since fc still around 11.0 right at top of target range
11.0
FC
0.5
CC
7.5
pH
75
TA
270
CH
80
CYA
3300
SALT
75 °F
TEMP
-0.53
CSI
40 lbs of Salt
10.5
FC
0.5
CC
7.5
pH
80
CYA
3200
SALT
77 °F
TEMP
-0.48
CSI
I lowered SWG to 25% since fc has not decreased The salt reading of 2800 per Taylor 1766 is lower than the Hayward reading of 3200. I posted a question on forum
11.5
FC
0.5
CC
7.5
pH
75
TA
85
CYA
2800
SALT
73 °F
TEMP
-0.52
CSI
SWG indicated 3300 salt - my test results 2800
Fc did not drop - so left it at 30%
11.0
FC
0.5
CC
7.5
pH
70
TA
80
CYA
75 °F
TEMP
-0.55
CSI
Used approximately 2.2 fc & SWG at 30% made 1.2fc. Therefore left SWG at 30% to make 1.2 fc . Therefore expecting fc to drop tomorrow by 1.0 to 9.5. Pool math recommend 6.0 ppm. I like 8 to 9ppm
10.5
FC
0.5
CC
7.5
pH
75
TA
80
CYA
78 °F
TEMP
-0.47
CSI
11.5
FC
0.5
CC
7.4
pH
80
TA
80
CYA
3000
SALT
80 °F
TEMP
-0.50
CSI
12.0
FC
0.0
CC
7.4
pH
80
TA
80
CYA
79 °F
TEMP
-0.51
CSI
Test results taken by EV. I told him to lower SWG to 30 % - since fc increased to 13.0 from 8.0 in two days . When SWG was at 62%
13.0
FC
7.4
pH
-0.57
CSI
Noah did readings again today- Asked him to raise SWG to 62%. Since fc dropped to 8.0 from 8.5 He said that it rained hard today
8.0
FC
7.4
pH
70
TA
280
CH
70
CYA
80 °F
TEMP
-0.57
CSI
Noah did the readings- I said to increase the SWG up 5% to 55% since fc dropped from 9.0 to 8.5
8.5
FC
7.4
pH
75
TA
240
CH
75
CYA
78 °F
TEMP
-0.62
CSI
Increased the SWG by 10% to 50%. Since the FC used a net of 2.0 ppm
9.0
FC
0.5
CC
7.4
pH
75
TA
80
CYA
3100
SALT
79 °F
TEMP
-0.57
CSI
11.0
FC
-0.67
CSI
Lowered SWG to 40%
12.5
FC
-0.67
CSI
10.0
FC
0.5
CC
7.3
pH
70
TA
265
CH
70
CYA
3200
SALT
81 °F
TEMP
-0.67
CSI
Water level on skimmer - 2&1/2 down from Top 4&1/2 up from bottom After rain overflow #3
Vacuumed Backwashed
Filter Pressure:13
SWG turned down to ~50%
11.0
FC
0.5
CC
7.3
pH
70
TA
75
CYA
83 °F
TEMP
-0.63
CSI
Turned SWG up. To ~60%
Added 91 oz of lc to raise fc ~5 to 8ppm
91 oz of Liquid Chlorine • 12.5%
2.7
FC
0.5
CC
72
CYA
3000
SALT
84 °F
TEMP
-0.58
CSI
5.5
FC
0.5
CC
82 °F
TEMP
-0.57
CSI
31 oz of Dry Stabilizer
Added 18 oz of lc to raise fc by 1.0ppm to 8.0 And 31 oz of dry stabilizer to raise CYA by about 13 to get to 75 to 78 And 40 lbs of salt to increase to 3166 from 2900
18 oz of Liquid Chlorine • 12.5%
7.0
FC
0.5
CC
7.4
pH
65
CYA
2900
SALT
85 °F
TEMP
-0.54
CSI
Turned on SWG at 30%
8.0
FC
0.5
CC
83 °F
TEMP
-0.58
CSI
11.0
FC
85 °F
TEMP
-0.57
CSI
9.5
FC
0.5
CC
70
CYA
84 °F
TEMP
-0.58
CSI
Swimmer load 10 people
Turned SWG off
12.5
FC
0.5
CC
7.4
pH
65
TA
65
CYA
83 °F
TEMP
-0.57
CSI
We received 3” of rain
SWG reduced to 35%. And timer to 10 hrs Since fc increased from 10.5 To 12.5
12.5
FC
0.5
CC
75
CYA
81 °F
TEMP
-0.52
CSI
Vacuumed Brushed
Filter Pressure:12
10.5
FC
0.5
CC
75
CYA
3100
SALT
81 °F
TEMP
-0.52
CSI
Salt reading of 2800 must have been incorrect- see 7pm reading of 3100. Same as Hayward cell reading
12.5
FC
0.0
CC
7.4
pH
75
TA
62
CYA
2800
SALT
79 °F
TEMP
-0.49
CSI
Added dry stabilizer to increase CYA by 15 to reach 75
32 oz of Dry Stabilizer
12.0
FC
0.0
CC
7.4
pH
75
TA
60
CYA
80 °F
TEMP
-0.50
CSI
Lowered SWG to 70%. - since fc is at 11.5 steady over 1.5 over target level It rained 1/2 “ this morning
11.5
FC
0.0
CC
82 °F
TEMP
-0.54
CSI
11.5
FC
0.5
CC
65
CYA
84 °F
TEMP
-0.52
CSI
Lowered SWG to 60%. FC went up 4.5 ppm at 100% in about 7 hours of run time (7am to 2:15pm)
11.5
FC
0.5
CC
7.4
pH
70
CYA
87 °F
TEMP
-0.50
CSI
Lowered SWG to 12 hrs @ 100% tonight We had about 6 swimmers on & off today. & heated pool to about 85 degrees
7.5
FC
0.5
CC
7.3
pH
70
TA
60
CYA
85 °F
TEMP
-0.59
CSI
8.5
FC
0.2
CC
7.3
pH
70
TA
70
CYA
81 °F
TEMP
-0.64
CSI
Adde 43 oz dry conditioner - should increase CYA by about 18 to near 70
43 oz of Dry Stabilizer
13.5
FC
0.2
CC
7.3
pH
70
TA
50
CYA
3100
SALT
80 °F
TEMP
-0.61
CSI
14.0
FC
0.2
CC
7.4
pH
81 °F
TEMP
-0.46
CSI
OCLT passed for the third nite again
17.5
FC
0.2
CC
78 °F
TEMP
-0.59
CSI
17.0
FC
0.2
CC
80 °F
TEMP
-0.57
CSI
OCLT passed 2nd night - it increased by 1.0
21.0
FC
-0.56
CSI
OCLY fourth night 20.0. -..full day fc usage is 5.5
20.0
FC
81 °F
TEMP
-0.56
CSI
22.0
FC
0.2
CC
7.3
pH
80
TA
280
CH
65
CYA
83 °F
TEMP
-0.54
CSI
I’m treating this as a OCLT pass - fc increased by 1.5 . I may not have waited long enough last nite to get the fc reading after adding lc
25.5
FC
70
CYA
81 °F
TEMP
-0.63
CSI
OCLT third nite 24ppm
24.0
FC
-0.58
CSI
Add 10 oz of lc to increase to 24.00 ppm - slam amount
10 oz of Liquid Chlorine • 12.5%
23.5
FC
-0.58
CSI
Vacuumed Brushed
Filter Pressure:12
24.5
FC
0.2
CC
7.2
pH
80
TA
60
CYA
85 °F
TEMP
-0.58
CSI
40 oz of 29% Muriatic Acid
Morning OCLT after loss of 3.5ppm Added 48oz of lc to get to slam of 29ppm from 26.5 ppm
48 oz of Liquid Chlorine • 12.5%
26.5
FC
0.2
CC
7.8
pH
81 °F
TEMP
-0.10
CSI
OCLT test 2nd night - 1st night after slamming procedures during day
30.0
FC
-0.43
CSI
10 oz of Liquid Chlorine • 12.5%
28.5
FC
-0.43
CSI
Slam process to increase fc to 29
147 oz of Liquid Chlorine • 12.5%
0.1 oz of Liquid Chlorine • 12.5%
21.0
FC
-0.43
CSI
Slam of chlorine to bring fc up to 30ppm
304 oz of Liquid Chlorine • 12.5%
12.5
FC
0.0
CC
7.4
pH
80
TA
75
CYA
85 °F
TEMP
-0.43
CSI
Slam process to raise fc to 31
2.5 gal of Liquid Chlorine • 12.5%
OCLT morning after loss of 2.8
5.8
FC
0.2
CC
-0.81
CSI
OCLT test
8.2
FC
0.2
CC
-0.81
CSI
Backwashed
Filter Pressure:12.5
Increased SWG time starting tomorrow to 14.25 hours still running at 100% The 70 oz of bleach just added to raise fc to 7.0 increase of 3.8
70 oz of Liquid Chlorine • 12.5%
3.2
FC
0.2
CC
7.0
pH
75
TA
80
CYA
3200
SALT
87 °F
TEMP
-0.81
CSI
4.4
FC
0.2
CC
7.1
pH
70
TA
70
CYA
84 °F
TEMP
-0.78
CSI
Increased SWG to 100% and run time to 13 hrs vs 12 hrs. Since FC dropped to 2.8
54 oz of Liquid Chlorine • 12.5%
2.8
FC
0.2
CC
7.2
pH
80
TA
75
CYA
85 °F
TEMP
-0.61
CSI
Vacuumed Brushed
Filter Pressure:13
4.6
FC
0.2
CC
83 °F
TEMP
-0.43
CSI
Sergio increased SWG to 90% due to high heat predicted (86 & 85 next few days)
48 oz of Liquid Chlorine • 12.5%
2.4
FC
0.2
CC
70
CYA
84 °F
TEMP
-0.43
CSI
Increased SWG to 60% for 12 hours
54 oz of Liquid Chlorine • 12.5%
2.6
FC
0.2
CC
75
CYA
85 °F
TEMP
-0.43
CSI
4.2
FC
0.2
CC
70
CYA
3200
SALT
83 °F
TEMP
-0.43
CSI
Increased SWG to 9 hrs at 60% due to forecasted heat wave for next two days
Turned SWG down to 55% with FC at 5.4
5.4
FC
0.4
CC
7.4
pH
80
TA
55
CYA
85 °F
TEMP
-0.37
CSI
5.0
FC
0.2
CC
-0.47
CSI
Turned SWG UP TO 60% after adding 26 oz of bleach. To get it to FC of 6.0 and hold at end of day
26 oz of Liquid Chlorine • 12.5%
4.6
FC
0.2
CC
7.4
pH
75
TA
75
CYA
84 °F
TEMP
-0.47
CSI
7.0
FC
0.2
CC
7.4
pH
80
TA
84 °F
TEMP
-0.44
CSI
6.6
FC
0.2
CC
7.3
pH
80
TA
83 °F
TEMP
-0.53
CSI
7.0
FC
0.2
CC
7.3
pH
-0.47
CSI
16 oz of 29% Muriatic Acid
48 oz of Liquid Chlorine • 12.5%
Vacuumed Brushed
Filter Pressure:12.5
3.2
FC
0.2
CC
7.4
pH
85
TA
80
CYA
87 °F
TEMP
-0.38
CSI
Lowered pump time to 8 hours
67 oz of Baking Soda
6.6
FC
0.2
CC
7.3
pH
60
TA
77
CYA
3000
SALT
87 °F
TEMP
-0.68
CSI
1.5 ppm FC • SWG  9.5 hrs @ 40 %
Lowered SWG % to 40%. Since FC went up by ~ .8%
6.2
FC
0.2
CC
7.3
pH
75
CYA
85 °F
TEMP
-0.59
CSI
5.4
FC
0.2
CC
7.3
pH
70
TA
75
CYA
84 °F
TEMP
-0.61
CSI
Vacuumed Brushed
29 oz of 29% Muriatic Acid
5.2
FC
0.2
CC
7.6
pH
75
TA
75
CYA
85 °F
TEMP
-0.28
CSI
1.9 ppm FC • SWG  9.5 hrs @ 50 %
4.8
FC
0.2
CC
7.5
pH
75
TA
70
CYA
84 °F
TEMP
-0.37
CSI
Backwashed
Filter Pressure:12
1.5 ppm FC • SWG  12 hrs @ 30 %
4.8
FC
0.2
CC
7.5
pH
75
TA
70
CYA
83 °F
TEMP
-0.37
CSI
21 oz of Baking Soda
Put SWG back to 35%
24 oz of Liquid Chlorine • 12.5%
4.2
FC
0.2
CC
7.4
pH
70
TA
75
CYA
3100
SALT
85 °F
TEMP
-0.50
CSI
1.4 ppm FC • SWG  12 hrs @ 29 %
3.6
FC
0.2
CC
75
CYA
85 °F
TEMP
-0.42
CSI
0.7 ppm FC • SWG  12 hrs @ 15 %
Increased SWG to 35% total for 12 hours
5.8
FC
0.2
CC
7.5
pH
70
TA
300
CH
80
CYA
84 °F
TEMP
-0.45
CSI
Had about 7 or 8 people in pool for pats bday
7.6
FC
0.2
CC
7.4
pH
75
TA
75
CYA
85 °F
TEMP
-0.48
CSI
SWG on at 10% for 12 hours
8.4
FC
0.2
CC
7.4
pH
75
TA
70
CYA
82 °F
TEMP
-0.50
CSI
24 oz of Dry Stabilizer
42 oz of Baking Soda
Turned SWG down to 30% since FC increased by ~ 1.4
7.2
FC
0.2
CC
7.3
pH
65
TA
60
CYA
82 °F
TEMP
-0.65
CSI
23 oz of 29% Muriatic Acid
5.6
FC
0.2
CC
7.5
pH
85 °F
TEMP
-0.41
CSI
10 oz of 29% Muriatic Acid
Drop FC increased by 1.0 in one day to 6.2. Lowered setting from 50% to 38% SWG reads 3200 same as Taylor K1766
6.2
FC
0.2
CC
7.6
pH
70
TA
68
CYA
3200
SALT
85 °F
TEMP
-0.32
CSI
5.2
FC
0.2
CC
82 °F
TEMP
-0.36
CSI
Turned SWG on 50% at 6:00 pm
SWG indicates salt at 3200
5.0
FC
0.2
CC
7.6
pH
70
TA
70
CYA
83 °F
TEMP
-0.35
CSI
7.7
FC
0.2
CC
7.5
pH
70
TA
83 °F
TEMP
-0.42
CSI
Still have SWG set to off
8.0
FC
0.2
CC
83 °F
TEMP
-0.47
CSI
8.4
FC
0.2
CC
7.4
pH
62
CYA
83 °F
TEMP
-0.47
CSI
Still have SWG set at off due to FC at 9.0 . This morning so far has decreased about 1.4 ppm
9.0
FC
0.2
CC
7.4
pH
75
TA
65
CYA
84 °F
TEMP
-0.47
CSI
Vacuumed Brushed
Filter Pressure:12
10.6
FC
0.2
CC
7.4
pH
70
TA
70
CYA
3300
SALT
85 °F
TEMP
-0.51
CSI
Lowered SWG down to 10% to get the FC down to under 6.0 ( the target amount is 4.0) The current FC reading is 10.2 and increased with 48% settings and hot sun on pool
10.3
FC
0.2
CC
-0.51
CSI
27 oz of 29% Muriatic Acid
2nd night for SWG GC went up by 1.5 so lowered % to 48%
The SWG also reads 3300 ppm of salt . My readings are 3300 from Taylor K1766 kit
9.8
FC
0.2
CC
7.7
pH
80
TA
62
CYA
3300
SALT
85 °F
TEMP
-0.13
CSI
8.4
FC
0.2
CC
-0.28
CSI
First day for SWG - set at 79%
7.0
FC
0.2
CC
3200
SALT
85 °F
TEMP
-0.13
CSI
RM pools Sergio Montes installed Hayward Autoright 900 with Tcell 940
33 oz of Liquid Chlorine • 12.5%
5.2
FC
0.2
CC
55
CYA
3200
SALT
85 °F
TEMP
-0.28
CSI
17 oz of Dry Stabilizer
40 lbs of Salt
21 oz of Liquid Chlorine • 12.5%
6.2
FC
0.2
CC
7.6
pH
70
TA
60
CYA
2800
SALT
84 °F
TEMP
-0.29
CSI
20 oz of Liquid Chlorine • 12.5%
6.6
FC
0.2
CC
7.6
pH
70
TA
60
CYA
2800
SALT
85 °F
TEMP
-0.28
CSI
22 oz of Dry Stabilizer
6.6
FC
0.2
CC
7.6
pH
70
TA
290
CH
48
CYA
1800
SALT
84 °F
TEMP
-0.20
CSI
160 lbs of Salt
18 oz of Liquid Stabilizer
1 g of Baking Soda
1 g of Baking Soda
1 g of Baking Soda
1 g of Baking Soda
21 oz of Baking Soda
16 oz of Liquid Chlorine • 12.5%
6.4
FC
0.2
CC
7.4
pH
65
TA
52
CYA
700
SALT
85 °F
TEMP
-0.32
CSI
9.2
FC
0.2
CC
7.4
pH
60
TA
55
CYA
84 °F
TEMP
-0.48
CSI
Vacuumed Brushed
Removed remainder of 3 leslies chlorine tricolor tabs
13.0
FC
0.2
CC
7.6
pH
70
TA
48
CYA
84 °F
TEMP
-0.08
CSI
Copper. .3 Iron. 0.0
10.4
FC
0.2
CC
7.7
pH
70
TA
300
CH
45
CYA
80 °F
TEMP
-0.01
CSI
24 oz of TriChlor
Leslies tricolor tabs 8 oz each Each Raise CYA BY 1.3 Fc by 2.2 each Lower PH BY .1 Raise salt by 1.8
40 oz of Liquid Stabilizer
3 lbs of Baking Soda
6.0
FC
0.2
CC
82 °F
TEMP
-0.36
CSI
Copper I got .2. Leslie’s got .5 this morning Iron Leslie’s got 0.0
48 oz of Liquid Chlorine • 12.5%
Salt per Leslie’s tds of 600. I got 800 salt per
4.4
FC
0.2
CC
7.5
pH
58
TA
273
CH
50
CYA
800
SALT
80 °F
TEMP
-0.38
CSI
7.8
FC
0.2
CC
7.4
pH
78 °F
TEMP
-0.44
CSI
16 oz of Liquid Chlorine • 12.5%
Vacuumed Brushed
Filter Pressure:12
5.6
FC
0.2
CC
7.4
pH
45
CYA
76 °F
TEMP
-0.45
CSI
20 oz of Liquid Chlorine • 12.5%
5.8
FC
0.2
CC
7.3
pH
60
TA
48
CYA
78 °F
TEMP
-0.54
CSI
26 oz of 29% Muriatic Acid
7.4
FC
0.2
CC
7.6
pH
70
TA
45
CYA
76 °F
TEMP
-0.18
CSI
Vacuumed Brushed
Filter Pressure:12
7.2
FC
0.2
CC
74 °F
TEMP
-0.29
CSI
65 oz of Liquid Chlorine • 12.5%
3.6
FC
0.4
CC
7.6
pH
60
TA
74 °F
TEMP
-0.29
CSI
5.2
FC
0.2
CC
7.5
pH
74 °F
TEMP
-0.38
CSI
25 oz of Liquid Chlorine • 12.5%
5.0
FC
0.2
CC
74 °F
TEMP
-0.29
CSI
7.4
FC
0.2
CC
7.6
pH
76 °F
TEMP
-0.27
CSI
36 oz of Liquid Chlorine • 12.5%
5.2
FC
0.2
CC
7.4
pH
60
TA
300
CH
48
CYA
75 °F
TEMP
-0.48
CSI
Vacuumed Backwashed
Filter Pressure:12
16 oz of Liquid Chlorine • 12.5%
11 oz of 29% Muriatic Acid
6.0
FC
0.2
CC
7.6
pH
65
TA
46
CYA
75 °F
TEMP
-0.22
CSI
20 oz of Liquid Chlorine • 12.5%
5.6
FC
0.2
CC
7.6
pH
60
TA
75 °F
TEMP
-0.28
CSI
16 oz of 29% Muriatic Acid
60 oz of Liquid Chlorine • 12.5%
3.8
FC
0.2
CC
7.6
pH
48
CYA
76 °F
TEMP
-0.17
CSI
10.5 oz of pH Down / Dry Acid
6.2
FC
0.2
CC
7.8
pH
70
TA
310
CH
43
CYA
75 °F
TEMP
0.02
CSI
18 oz of Liquid Chlorine • 12.5%
5.8
FC
0.2
CC
7.6
pH
-0.23
CSI
7.0
FC
0.2
CC
-0.61
CSI
60 oz of Liquid Chlorine • 12.5%
3.6
FC
0.2
CC
7.2
pH
70
TA
290
CH
72 °F
TEMP
-0.61
CSI
53 oz of Calcium Chloride
5.2 oz of pH Down / Dry Acid
6.2
FC
0.2
CC
7.7
pH
70
TA
280
CH
48
CYA
72 °F
TEMP
-0.15
CSI
23 oz of Liquid Chlorine • 12.5%
5.4
FC
0.2
CC
-0.29
CSI
7.0
FC
0.2
CC
-0.29
CSI
7.4
FC
0.2
CC
-0.29
CSI
7.0
FC
0.2
CC
45
CYA
68 °F
TEMP
-0.29
CSI
18 oz of Liquid Chlorine • 12.5%
5.8
FC
0.2
CC
-0.24
CSI
7.2
FC
0.2
CC
-0.24
CSI
8.0
FC
0.4
CC
47
CYA
-0.24
CSI
18 oz of Liquid Chlorine • 12.5%
5.2
FC
0.2
CC
7.6
pH
70
TA
270
CH
45
CYA
74 °F
TEMP
-0.24
CSI
6.6
FC
0.2
CC
-0.25
CSI
7.0
FC
0.2
CC
-0.25
CSI
29 oz of Liquid Chlorine • 12.5%
4.6
FC
0.2
CC
-0.25
CSI
5.6
FC
0.2
CC
48
CYA
-0.25
CSI
5.0
FC
0.0
CC
42
CYA
-1.00
CSI
Vacuumed Brushed
Copper. .1
5.0
FC
0.2
CC
7.6
pH
70
TA
280
CH
45
CYA
72 °F
TEMP
-0.24
CSI
8 lbs of Calcium Chloride
Back yard system Copper. .3 to .4 Iron zero
Copper. .1 Iron. 0.0 Back yard hose Copper. Zero to .1. Iron zero House filter Copper. Zero to .1
6.8
FC
0.2
CC
7.6
pH
70
TA
240
CH
38
CYA
72 °F
TEMP
-0.28
CSI
48 oz of Liquid Chlorine • 12.5%
3.6
FC
0.0
CC
-1.00
CSI
5.6
FC
0.2
CC
-0.31
CSI
6.4
FC
0.2
CC
-0.31
CSI
Copper test maybe .1 Iron. Zero
7.0
FC
0.0
CC
7.6
pH
-0.31
CSI
35 oz of Liquid Chlorine • 12.5%
3.8
FC
0.0
CC
-0.40
CSI
5.6
FC
0.2
CC
7.5
pH
70
TA
240
CH
70 °F
TEMP
-0.40
CSI
5.8
FC
0.2
CC
7.6
pH
70
TA
250
CH
40
CYA
70 °F
TEMP
-0.29
CSI
6.0
FC
0.2
CC
7.6
pH
70
TA
250
CH
40
CYA
-0.31
CSI
5.8
FC
0.0
CC
40
CYA
-0.24
CSI
5.6
FC
0.2
CC
-0.24
CSI
5.4
FC
0.2
CC
-0.24
CSI
8.2 oz of TriChlor
4.2
FC
0.2
CC
-0.24
CSI
6.0
FC
0.2
CC
7.6
pH
80
TA
250
CH
40
CYA
68 °F
TEMP
-0.24
CSI
Copper test 0.1 maybe 0.0 Iron test. 0.0
6.0
FC
0.2
CC
7.4
pH
80
TA
-0.41
CSI
5.4
FC
0.2
CC
-0.60
CSI
33 oz of Liquid Chlorine • 12.5%
Brushed
3.2
FC
0.2
CC
7.2
pH
80
TA
250
CH
40
CYA
70 °F
TEMP
-0.60
CSI
Brushed
6.6
FC
0.2
CC
-0.01
CSI
7.2
FC
0.2
CC
7.8
pH
80
TA
260
CH
40
CYA
70 °F
TEMP
-0.01
CSI
2 lbs of 73% Cal-Hypo
0.4
FC
0.2
pH
-1.00
CSI
Copper test .2 Iron 0.0
5.4
FC
0.2
CC
7.6
pH
80
TA
230
CH
40
CYA
70 °F
TEMP
-0.25
CSI
24.6 oz of TriChlor
Vacuumed Backwashed
12.2
FC
0.2
CC
7.6
pH
80
TA
130
CH
40
CYA
70 °F
TEMP
-0.50
CSI
12.1
FC
0.2
CC
7.4
pH
80
TA
140
CH
40
CYA
72 °F
TEMP
-0.64
CSI
12.4
FC
0.4
CC
32
CYA
-0.63
CSI
0.8
FC
0.0
CC
7.4
pH
80
TA
140
CH
32
CYA
72 °F
TEMP
-0.63
CSI
64 oz of Liquid Stabilizer
Added culator pack to skimmer from Leslies to remove metals
Confirmed results with Leslie’s test of same sample - Leslie’s FC level of 3.28 is .4 higher than my result Leslie got .3 copper and 0.0 iron
2.8
FC
0.2
CC
7.4
pH
80
TA
130
CH
30
CYA
72 °F
TEMP
-0.65
CSI
I Set up a thread on the TFP forum Re chlorine level instability
63 oz of Liquid Chlorine • 12.5%
0.4
FC
0.0
CC
7.4
pH
80
TA
130
CH
30
CYA
72 °F
TEMP
-0.65
CSI
18 lbs of Calcium Chloride
Vacuumed
Filter Pressure:10
16 oz of Baking Soda
3.4
FC
0.2
CC
30
CYA
72 °F
TEMP
-1.13
CSI
1.8
FC
0.6
CC
7.4
pH
70
TA
50
CH
32
CYA
72 °F
TEMP
-1.13
CSI
Backwashed
61 gal of Liquid Chlorine • 12.5%
1.8
FC
0.2
CC
7.4
pH
70
TA
50
CH
38
CYA
70 °F
TEMP
-1.16
CSI
0.5 gal of Liquid Stabilizer
93 gal of Liquid Stabilizer
0.1 oz of Liquid Stabilizer
Opened Pool Vacuumed Brushed Cleaned Filter
Filter Pressure:10
2.2
FC
0.4
CC
7.2
pH
60
TA
50
CH
20
CYA
68 °F
TEMP
-1.41
CSI
1.2
FC
0.0
CC
7.4
pH
60
TA
40
CH
30
CYA
58 °F
TEMP
-1.44
CSI
8.2
FC
0.2
CC
7.4
pH
100
TA
240
CH
50
CYA
70 °F
TEMP
-0.34
CSI
56 oz of TriChlor
6.7
FC
0.2
CC
7.4
pH
100
TA
240
CH
50
CYA
70 °F
TEMP
-0.34
CSI
7.2
FC
0.2
CC
7.4
pH
100
TA
50
CYA
74 °F
TEMP
-0.25
CSI
16 oz of TriChlor
58 oz of Liquid Chlorine • 12%
Vacuumed Backwashed
Filter Pressure:12
3.0
FC
0.2
CC
45
CYA
72 °F
TEMP
-0.65
CSI
7.2
FC
0.2
CC
7.0
pH
100
TA
270
CH
50
CYA
72 °F
TEMP
-0.65
CSI
7.6
FC
0.2
CC
-0.18
CSI
6.2
FC
0.2
CC
-0.18
CSI
6.0
FC
0.4
CC
-0.18
CSI
6.6
FC
0.2
CC
7.4
pH
110
TA
270
CH
40
CYA
76 °F
TEMP
-0.18
CSI
7.2
FC
0.2
CC
-0.14
CSI
40 oz of Liquid Chlorine • 12%
4.8
FC
0.4
CC
-0.14
CSI
7.7 oz of Liquid Chlorine • 12%
4.6
FC
0.4
CC
-0.14
CSI
5.8
FC
0.2
CC
-0.14
CSI
5.8
FC
0.2
CC
-0.14
CSI
54 oz of Liquid Chlorine • 12%
2.2
FC
0.4
CC
7.4
pH
120
TA
270
CH
40
CYA
76 °F
TEMP
-0.14
CSI
10 oz of Liquid Chlorine • 12%
4.4
FC
0.2
CC
7.4
pH
120
TA
270
CH
40
CYA
76 °F
TEMP
-0.14
CSI
45 oz of Liquid Chlorine • 12%
3 lbs of pH Up / Soda Ash / Washing Soda
3.6
FC
0.4
CC
7.0
pH
100
TA
270
CH
40
CYA
80 °F
TEMP
-0.58
CSI
73 oz of Liquid Chlorine • 12%
2.2
FC
0.2
CC
7.0
pH
100
TA
270
CH
40
CYA
81 °F
TEMP
-0.56
CSI
115 oz of Liquid Chlorine • 12%
0.0
FC
0.0
CC
7.0
pH
100
TA
270
CH
50
CYA
80 °F
TEMP
-0.59
CSI
16 oz of pH Down / Dry Acid
2.0
FC
0.2
CC
7.6
pH
110
TA
270
CH
50
CYA
82 °F
TEMP
0.05
CSI
6.0
FC
0.2
CC
7.6
pH
120
TA
270
CH
50
CYA
80 °F
TEMP
0.08
CSI
6.0
FC
0.2
CC
7.6
pH
110
TA
280
CH
50
CYA
80 °F
TEMP
0.05
CSI
115 oz of Liquid Chlorine • 12%
0.0
FC
0.0
CC
7.4
pH
110
TA
290
CH
50
CYA
80 °F
TEMP
-0.13
CSI
6.4
FC
0.2
CC
7.4
pH
110
TA
290
CH
42
CYA
79 °F
TEMP
-0.12
CSI
5.0
FC
0.4
CC
7.5
pH
110
TA
290
CH
45
CYA
78 °F
TEMP
-0.04
CSI
46 oz of Liquid Chlorine • 12%
60 oz of Liquid Stabilizer
13 lbs of Calcium Chloride
2.6
FC
0.4
CC
7.4
pH
120
TA
220
CH
25
CYA
78 °F
TEMP
-0.19
CSI
16.5 lbs of Calcium Chloride
42 oz of Baking Soda
6.0
FC
0.5
CC
7.0
pH
90
TA
120
CH
40
CYA
78 °F
TEMP
-0.98
CSI
1 oz of pH Up / Soda Ash / Washing Soda
67 oz of pH Up / Soda Ash / Washing Soda
58 oz of Liquid Chlorine • 12%
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:12
2.0
FC
0.5
CC
6.7
pH
60
TA
120
CH
35
CYA
80 °F
TEMP
-1.44
CSI
12.0
FC
0.5
CC
7.0
pH
75
TA
130
CH
40
CYA
82 °F
TEMP
-1.01
CSI
18.0
FC
0.5
CC
7.0
pH
90
TA
170
CH
55
CYA
78 °F
TEMP
-0.86
CSI
26.0
FC
0.5
CC
7.2
pH
120
TA
200
CH
80
CYA
82 °F
TEMP
-0.45
CSI
3 gal of Liquid Chlorine • 10%
12 oz of pH Down / Dry Acid
Vacuumed Cleaned Filter
Filter Pressure:10
18.0
FC
0.5
CC
7.4
pH
110
TA
200
CH
80
CYA
83 °F
TEMP
-0.30
CSI
18.0
FC
0.5
CC
7.4
pH
110
TA
200
CH
76
CYA
83 °F
TEMP
-0.29
CSI
$21.00 on Liquid Chlorine / Bleach • 10%
Vacuumed Brushed
Filter Pressure:10
3 lbs of 73% Cal-Hypo
Vacuumed Brushed
8.5
FC
0.5
CC
7.4
pH
110
TA
200
CH
70
CYA
84 °F
TEMP
-0.28
CSI
10.8
FC
0.4
CC
7.6
pH
110
TA
200
CH
60
CYA
82 °F
TEMP
-0.09
CSI
10.8
FC
0.3
CC
7.5
pH
110
TA
200
CH
58
CYA
80 °F
TEMP
-0.20
CSI
10.5
FC
0.5
CC
7.4
pH
90
TA
136
CH
76
CYA
78 °F
TEMP
-0.61
CSI
7.0
FC
0.2
CC
7.3
pH
98
TA
130
CH
48
CYA
80 °F
TEMP
-0.62
CSI
10.0
FC
10.2
CC
7.2
pH
125
TA
260
CH
85
CYA
78 °F
TEMP
-0.36
CSI
8 lbs of Calcium Chloride
32 oz of pH Up / Soda Ash / Washing Soda
Filter Pressure:10
Flow Rate:40