17123 Circa Oriente

Volume: 35000 Gallons
Build Type: Plaster
64 oz of 29% Muriatic Acid
5.2
FC
0.0
CC
7.9
pH
70
TA
3300
SALT
73 °F
TEMP
0.22
CSI
5.5
FC
0.0
CC
7.9
pH
71
TA
637
CH
57
CYA
3442
SALT
73 °F
TEMP
0.22
CSI
Cleaned IC60 for 10 min Changed IntelliFlow Solar from 3100 to 3200 rpm. Pump pressure changed from 22 to 23.
Brushed Cleaned Filter
Filter Pressure:22
40 lbs of Salt
2 lbs of Dichlor
64 oz of 29% Muriatic Acid
4.2
FC
0.2
CC
7.8
pH
80
TA
3450
SALT
80 °F
TEMP
0.27
CSI
IC60 60% -> 80% Enable Solar Repaint WhisperFlow pump Replace 50uF capacitor Replace spa jet pump check valve
1 lbs of Dichlor
64 oz of 29% Muriatic Acid
2.4
FC
0.0
CC
8.0
pH
80
TA
3150
SALT
71 °F
TEMP
0.40
CSI
IC60 = 60% POOL: 10AM to 4PM SPA: 2:00PM to 4:15PM JETS: 2:00PM to 4:15PM
64 oz of 29% Muriatic Acid
3.2
FC
0.0
CC
8.0
pH
90
TA
3050
SALT
70 °F
TEMP
0.47
CSI
Replace top Jandy 4717 3-port valve
3.6
FC
0.0
CC
7.6
pH
3050
SALT
66 °F
TEMP
-0.03
CSI
64 oz of 29% Muriatic Acid
2 lbs of Dichlor
IC60 30 -> 60%
0.8
FC
0.0
CC
8.0
pH
80
TA
3050
SALT
67 °F
TEMP
0.37
CSI
Brushed Cleaned Filter
Filter Pressure:12
2 lbs of Dichlor
Brushed
IC60 20% -> 30%
0.8
FC
2950
SALT
65 °F
TEMP
0.36
CSI
1 lbs of Dichlor
Brushed
64 oz of 29% Muriatic Acid
64 oz of 29% Muriatic Acid
1.8
FC
0.0
CC
8.0
pH
80
TA
3150
SALT
61 °F
TEMP
0.32
CSI
Cleaned IC60 for 10 min IC60 = 20% POOL: 10AM to 2PM SPA: 2:00PM to 2:15PM JETS: 2:00PM to 2:05PM
Cleaned Filter
Filter Pressure:13
64 oz of 29% Muriatic Acid
6.9
FC
0.0
CC
7.8
pH
78
TA
670
CH
59
CYA
3643
SALT
61 °F
TEMP
0.09
CSI
IC60 60% -> 40%
64 oz of 29% Muriatic Acid
5.4
FC
0.0
CC
8.0
pH
80
TA
3450
SALT
65 °F
TEMP
0.26
CSI
64 oz of 29% Muriatic Acid
4.2
FC
0.2
CC
8.0
pH
80
TA
3450
SALT
77 °F
TEMP
0.38
CSI
Cleaned IC60 for 10 min
Cleaned Filter
Filter Pressure:22
64 oz of 29% Muriatic Acid
3.8
FC
0.2
CC
8.0
pH
80
TA
3500
SALT
72 °F
TEMP
0.33
CSI
64 oz of 29% Muriatic Acid
5.8
FC
0.2
CC
7.8
pH
70
TA
3450
SALT
79 °F
TEMP
0.12
CSI
IC60 = 60% POOL: 10AM to 4PM SPA: 4:00PM to 4:15PM JETS: 4:00PM to 4:05PM
64 oz of 29% Muriatic Acid
7.6
FC
0.2
CC
8.0
pH
80
TA
3500
SALT
76 °F
TEMP
0.36
CSI
64 oz of 29% Muriatic Acid
4.0
FC
0.2
CC
8.0
pH
80
TA
3500
SALT
87 °F
TEMP
0.45
CSI
64 oz of 29% Muriatic Acid
4.6
FC
0.0
CC
8.0
pH
80
TA
3600
SALT
87 °F
TEMP
0.45
CSI
Replaced filter gasket, relief valve, and pressure gauge.
Cleaned Filter
Filter Pressure:22
64 oz of 29% Muriatic Acid
4.4
FC
0.0
CC
7.8
pH
80
TA
3650
SALT
88 °F
TEMP
0.27
CSI
1 lbs of Dichlor
4.0
FC
0.2
CC
7.7
pH
0.17
CSI
64 oz of 29% Muriatic Acid
2.2
FC
0.4
CC
8.0
pH
80
TA
3500
SALT
87 °F
TEMP
0.45
CSI
3.5
FC
0.2
CC
7.4
pH
578
CH
63
CYA
3035
SALT
-0.08
CSI
Replaced two pool/spa actuator caps and gaskets. ATIE 3-Way/2-Way Pool Valve Cover/Cap 4606 with O-ring 1132+ and Shaft O-ring R0487100 For Zodiac Jandy Black/Gray 3-Way/2-Way Pool Valve Covers 4606+, 1303+, 4734+, 1304+ (2 Pack)
1 lbs of Dichlor
64 oz of 29% Muriatic Acid
1.8
FC
0.2
CC
7.8
pH
80
TA
3350
SALT
88 °F
TEMP
0.29
CSI
1 lbs of Dichlor
Cleaned IC60 for 5min IC60 = 100% Replaced four ATIE Neverlube Diverter Valve Kit 4720 Replacement for Zodiac Jandy 2 Port or 3 Port Never Lube Diverter Valve 4720 (2 Pack)
Brushed Cleaned Filter
2.7 oz of 29% Muriatic Acid
1.6
FC
0.2
CC
7.8
pH
80
TA
3650
SALT
84 °F
TEMP
0.23
CSI
IC60 = 80% Replaced IntelliFlow VS 011018 with IntelliFlo/Pro3 VSF 011075 Installed by Pool Time (Aaron Wicht, Armando). Spa RPM = 72% = 2600 (40 GPM) Pool RPM = 76.9% = 2800 (62 GPM) Cleaner RPM = 2800 Solar RPM = 85.5% = 3100 (52 GPM) Spa filter pressure = 18 Pool filter pressure = 13 Solar filter pressure = 22
64 oz of 29% Muriatic Acid
Intelliflow VS Pump, P/N 011018 trips breaker, stopped working.
1 oz of Dichlor
0.8
FC
0.1
CC
7.5
pH
601
CH
66
CYA
3533
SALT
82 °F
TEMP
-0.06
CSI
IC60 = 60%
64 oz of 29% Muriatic Acid
2.0
FC
0.2
CC
7.8
pH
80
TA
3600
SALT
84 °F
TEMP
0.25
CSI
IC60 = 50%
2.7 oz of 29% Muriatic Acid
2.8
FC
0.0
CC
7.6
pH
80
TA
3500
SALT
81 °F
TEMP
0.04
CSI
Spa RPM = 2650 Pool RPM = 2850 Cleaner RPM = 2850 Solar RPM = 3050 Pool filter pressure = 14 Solar filter pressure = 22
Replaced Pool/Spa fill Pool Valve Actuator Micro Switch Replacement for Pentair Compool CVA 24 (2-PK) Brand: TUAIC
120 lbs of Salt
64 oz of 29% Muriatic Acid
3.6
FC
0.0
CC
7.8
pH
90
TA
2950
SALT
72 °F
TEMP
0.25
CSI
Brushed Cleaned Filter
Filter Pressure:30
64 oz of 29% Muriatic Acid
4.4
FC
0.2
CC
7.8
pH
90
TA
3000
SALT
72 °F
TEMP
0.25
CSI
13.5 lbs of Baking Soda
64 oz of 29% Muriatic Acid
4.2
FC
0.0
CC
7.8
pH
70
TA
2950
SALT
71 °F
TEMP
0.08
CSI
IC60 = 40%
64 oz of 29% Muriatic Acid
4.4
FC
0.2
CC
7.8
pH
70
TA
3000
SALT
76 °F
TEMP
0.13
CSI
1 lbs of Dichlor
2.7 oz of 29% Muriatic Acid
1.8
FC
0.0
CC
7.9
pH
70
TA
3000
SALT
74 °F
TEMP
0.20
CSI
IC60 = 50%
32 oz of 29% Muriatic Acid
2.4
FC
0.2
CC
7.8
pH
70
TA
3000
SALT
70 °F
TEMP
0.08
CSI
Cleaned IC60 for 5 min
Brushed Cleaned Filter
Filter Pressure:30
64 oz of 29% Muriatic Acid
2.0
FC
0.2
CC
8.0
pH
80
TA
2900
SALT
74 °F
TEMP
0.39
CSI
IC60 = 40%
32 oz of 29% Muriatic Acid
2.0
FC
0.2
CC
7.8
pH
70
TA
2900
SALT
79 °F
TEMP
0.16
CSI
32 oz of 29% Muriatic Acid
2.6
FC
0.0
CC
7.6
pH
70
TA
2900
SALT
68 °F
TEMP
-0.12
CSI
IC60 = 30%
32 oz of 29% Muriatic Acid
2.0
FC
0.2
CC
7.6
pH
70
TA
2900
SALT
73 °F
TEMP
-0.09
CSI
4.0
FC
7.4
pH
-0.36
CSI
Changed pool runtime From: 12AM - 4AM, IC60 = 10% To: 9AM - 5PM, IC60 = 20%
Cleaned Filter
Filter Pressure:16
16 oz of Dichlor
64 oz of 29% Muriatic Acid
0.8
FC
0.0
CC
8.0
pH
70
TA
2850
SALT
63 °F
TEMP
0.21
CSI
2.1
FC
0.1
CC
7.5
pH
618
CH
66
CYA
3483
SALT
-0.55
CSI
New suction pool sweep: Polaris MAXX Spa RPM = 2650 Pool RPM = 2950 Cleaner RPM = 2950 Solar RPM = 3450 Pool filter pressure = 16 Solar filter pressure = 30
13.5 lbs of Baking Soda
2.7 oz of 29% Muriatic Acid
4.3
FC
0.2
CC
7.3
pH
691
CH
76
CYA
3773
SALT
59 °F
TEMP
-0.73
CSI
4.0
FC
0.0
CC
7.5
pH
50
TA
2900
SALT
55 °F
TEMP
-0.61
CSI
64 oz of 29% Muriatic Acid
16 oz of Dichlor
3.5
FC
0.0
CC
7.7
pH
60
TA
2850
SALT
56 °F
TEMP
-0.25
CSI
Cleaned Filter
Filter Pressure:26
64 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.5
pH
60
TA
2750
SALT
55 °F
TEMP
-0.44
CSI
64 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.6
pH
60
TA
52 °F
TEMP
-0.39
CSI
Replaced 6 Jandy 7236 check valves. Moved Pool from PM to AM Pool: 12AM - 4AM Everyday
64 oz of 29% Muriatic Acid
8.5
FC
0.5
CC
7.7
pH
70
TA
3150
SALT
59 °F
TEMP
-0.11
CSI
64 oz of 29% Muriatic Acid
9.5
FC
1.0
CC
7.8
pH
70
TA
3200
SALT
59 °F
TEMP
-0.02
CSI
Pool runtime -2h Pool: 12PM - 4PM Everyday IC60 reduced from 20% to 10%
64 oz of 29% Muriatic Acid
12.0
FC
0.0
CC
7.6
pH
70
TA
3150
SALT
56 °F
TEMP
-0.24
CSI
Cleaned IC60 for 5min.
Cleaned Filter
Filter Pressure:26
10 lbs of Baking Soda
64 oz of 29% Muriatic Acid
14.0
FC
0.0
CC
7.6
pH
50
TA
3350
SALT
61 °F
TEMP
-0.48
CSI
IC60 reduced from 40% to 20%
14.5
FC
7.5
pH
742
CH
85
CYA
3401
SALT
-0.24
CSI
64 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.6
pH
3350
SALT
62 °F
TEMP
-0.20
CSI
IC60 reduced from 60% to 40%
64 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.6
pH
3450
SALT
64 °F
TEMP
-0.18
CSI
Brushed Cleaned Filter
Filter Pressure:26
64 oz of 29% Muriatic Acid
7.0
FC
0.5
CC
7.6
pH
75
TA
3450
SALT
67 °F
TEMP
-0.15
CSI
64 oz of 29% Muriatic Acid
7.0
FC
0.5
CC
7.6
pH
3450
SALT
72 °F
TEMP
-0.10
CSI
64 oz of 29% Muriatic Acid
8.0
FC
0.5
CC
7.7
pH
75
TA
3600
SALT
76 °F
TEMP
0.02
CSI
Pool runtime -2h Pool: 10AM - 4PM Everyday IC60 = 60%
64 oz of 29% Muriatic Acid
8.5
FC
0.0
CC
7.8
pH
75
TA
3500
SALT
73 °F
TEMP
0.08
CSI
Brushed Cleaned Filter
Filter Pressure:15
IC60 = 60% Cleaned IC60 5 minutes Pool filter pressure 15 @ 2750 Pool filter pressure 18 @ 3150 Solar filter pressure 26 @ 3150
64 oz of 29% Muriatic Acid
8.0
FC
0.5
CC
7.7
pH
75
TA
3750
SALT
78 °F
TEMP
0.03
CSI
8.0
FC
7.5
pH
689
CH
91
CYA
3727
SALT
-0.12
CSI
64 oz of 29% Muriatic Acid
7.0
FC
0.0
CC
7.6
pH
75
TA
3600
SALT
82 °F
TEMP
-0.08
CSI
16 oz of Dichlor
64 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
7.8
pH
75
TA
3600
SALT
81 °F
TEMP
0.11
CSI
Added Thermal Pool Solar Spa RPM = 2650 Pool RPM = 2750 Cleaner RPM = 2750 Solar RPM = 3150 Pool filter pressure = 15 Solar filter pressure = 26
16 oz of Dichlor
64 oz of 29% Muriatic Acid
6.5
FC
0.5
CC
7.8
pH
75
TA
3500
SALT
81 °F
TEMP
0.11
CSI
Cleaned IC60 5 minutes
Cleaned Filter
Filter Pressure:15
16 oz of Dichlor
64 oz of 29% Muriatic Acid
5.5
FC
0.5
CC
7.8
pH
75
TA
3500
SALT
84 °F
TEMP
0.13
CSI
7.0
FC
7.6
pH
-0.06
CSI
16 oz of Dichlor
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
75
TA
3500
SALT
83 °F
TEMP
0.13
CSI
5.5
FC
7.5
pH
-0.10
CSI
64 oz of 29% Muriatic Acid
16 oz of Dichlor
IC60 = 80%
3.5
FC
0.5
CC
7.6
pH
80
TA
3600
SALT
85 °F
TEMP
-0.01
CSI
IC60 = 60% Cleaned IC60 10 minutes
Cleaned Filter
Filter Pressure:15
64 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.8
pH
80
TA
3750
SALT
84 °F
TEMP
0.16
CSI
7.1
FC
0.2
CC
7.8
pH
540
CH
74
CYA
3127
SALT
0.17
CSI
64 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
7.6
pH
80
TA
3350
SALT
82 °F
TEMP
-0.08
CSI
64 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
8.0
pH
80
TA
3450
SALT
79 °F
TEMP
0.27
CSI
64 oz of 29% Muriatic Acid
6.5
FC
0.5
CC
7.6
pH
80
TA
3300
SALT
83 °F
TEMP
-0.06
CSI
64 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
7.8
pH
80
TA
3350
SALT
83 °F
TEMP
0.12
CSI
Rebuilt Hayward Navigator - Hayward AXV621417WHP A-frame, Pod, Turbine Kit - Hayward AXV079VP Spindle Gear Kit - ATIE AXW350 Flaps, Wings, Feet Kit
Brushed Cleaned Filter
Filter Pressure:15
5.0
FC
0.0
CC
7.6
pH
70
TA
3350
SALT
81 °F
TEMP
-0.18
CSI
64 oz of 29% Muriatic Acid
64 oz of 29% Muriatic Acid
5.0
FC
0.5
CC
7.8
pH
80
TA
3350
SALT
84 °F
TEMP
0.12
CSI
Add 4h to Pool, 2AM —> 6AM. Pool = 12PM-2PM, 12AM-6AM = 8h Cleaner = 12PM-2PM, 12AM-2AM = 4h
64 oz of 29% Muriatic Acid
4.0
FC
0.0
CC
7.8
pH
80
TA
3350
SALT
81 °F
TEMP
0.10
CSI
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
80
TA
3450
SALT
81 °F
TEMP
0.10
CSI
2 gal of 14.5% Muriatic Acid
5.0
FC
0.0
CC
8.0
pH
80
TA
562
CH
99
CYA
3500
SALT
78 °F
TEMP
0.25
CSI
IC60 = 100%
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
8.0
pH
70
TA
3450
SALT
76 °F
TEMP
0.06
CSI
64 oz of 29% Muriatic Acid
5 lbs of Baking Soda
6.5
FC
0.5
CC
7.8
pH
60
TA
3350
SALT
73 °F
TEMP
-0.30
CSI
1 gal of 29% Muriatic Acid
6.0
FC
0.0
CC
7.8
pH
70
TA
3350
SALT
72 °F
TEMP
-0.15
CSI
32 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
7.6
pH
70
TA
3500
SALT
77 °F
TEMP
-0.28
CSI
Cleaned IC60
Brushed Cleaned Filter
Filter Pressure:15
$36.50 on Muriatic acid
96 oz of 28.3% (18º Be) Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
70
TA
3350
SALT
74 °F
TEMP
-0.13
CSI
IC60 = 80%
64 oz of 29% Muriatic Acid
4.0
FC
0.0
CC
7.8
pH
70
TA
3300
SALT
72 °F
TEMP
-0.15
CSI
IC60 = 60%
32 oz of 29% Muriatic Acid
4.0
FC
0.0
CC
7.6
pH
70
TA
3350
SALT
71 °F
TEMP
-0.34
CSI
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
7.6
pH
70
TA
3300
SALT
72 °F
TEMP
-0.32
CSI
IC60 = 40%
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
70
TA
3300
SALT
68 °F
TEMP
-0.18
CSI
32 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.6
pH
70
TA
3300
SALT
70 °F
TEMP
-0.34
CSI
64 oz of 29% Muriatic Acid
7.5
FC
0.0
CC
7.8
pH
70
TA
3200
SALT
67 °F
TEMP
-0.19
CSI
7.4
pH
70
TA
-0.58
CSI
10 lbs of Baking Soda
32 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.6
pH
50
TA
3150
SALT
62 °F
TEMP
-0.77
CSI
IC60 = 30%
10.7
FC
7.3
pH
509
CH
104
CYA
3223
SALT
-1.02
CSI
10.0
FC
0.0
CC
7.4
pH
50
TA
3000
SALT
57 °F
TEMP
-0.83
CSI
32 oz of 29% Muriatic Acid
32 oz of 29% Muriatic Acid
9.0
FC
0.0
CC
7.5
pH
3000
SALT
59 °F
TEMP
-0.73
CSI
32 oz of 29% Muriatic Acid
9.0
FC
0.0
CC
7.4
pH
3050
SALT
60 °F
TEMP
-0.80
CSI
16 oz of 28.3% (18º Be) Muriatic Acid
8.5
FC
0.0
CC
7.4
pH
2900
SALT
54 °F
TEMP
-0.85
CSI
Pool = 12PM-2PM, 12AM-2AM = 4h Cleaner = 12PM-2PM, 12AM-2AM = 4h
32 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.5
pH
50
TA
2900
SALT
54 °F
TEMP
-0.78
CSI
Cleaned IC60.
IC60 = 40%
Brushed Cleaned Filter
Filter Pressure:15
7.5
FC
0.0
CC
7.4
pH
50
TA
625
CH
100
CYA
3000
SALT
58 °F
TEMP
-0.82
CSI
IC60 = 20% Pool = 12PM-1PM, 12AM-2AM = 3h Cleaner = 12PM-1PM, 12AM-2AM = 3h
10.0
FC
0.0
CC
7.4
pH
2950
SALT
55 °F
TEMP
-0.92
CSI
32 oz of 29% Muriatic Acid
32 oz of 29% Muriatic Acid
9.0
FC
0.0
CC
7.6
pH
50
TA
2950
SALT
55 °F
TEMP
-0.81
CSI
IC60 = 30%
7.4
pH
-0.93
CSI
32 oz of 29% Muriatic Acid
10.0
FC
0.0
CC
7.6
pH
50
TA
3000
SALT
54 °F
TEMP
-0.81
CSI
8.5
FC
0.0
CC
7.4
pH
60
TA
3050
SALT
59 °F
TEMP
-0.67
CSI
32 oz of 29% Muriatic Acid
8.0
FC
0.5
CC
7.6
pH
3200
SALT
59 °F
TEMP
-0.31
CSI
7.4
pH
-0.48
CSI
32 oz of 29% Muriatic Acid
9.0
FC
0.0
CC
7.6
pH
3150
SALT
59 °F
TEMP
-0.31
CSI
7.4
pH
-0.45
CSI
32 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.6
pH
3300
SALT
63 °F
TEMP
-0.28
CSI
7.4
pH
-0.42
CSI
32 oz of 29% Muriatic Acid
IC60 = 40%
9.0
FC
0.0
CC
7.6
pH
3350
SALT
67 °F
TEMP
-0.25
CSI
7.4
pH
-0.43
CSI
32 oz of 29% Muriatic Acid
10.0
FC
0.0
CC
7.6
pH
3450
SALT
67 °F
TEMP
-0.26
CSI
7.4
pH
-0.42
CSI
32 oz of 29% Muriatic Acid
9.0
FC
0.0
CC
7.6
pH
75
TA
3350
SALT
67 °F
TEMP
-0.25
CSI
7.4
pH
-0.44
CSI
32 oz of 29% Muriatic Acid
IC60 = 50% Pool = 12PM-2PM, 12AM-2AM = 4h Cleaner = 12PM-2PM, 12AM-2AM = 4h
10.0
FC
0.0
CC
7.6
pH
75
TA
3350
SALT
66 °F
TEMP
-0.27
CSI
7.4
pH
-0.42
CSI
32 oz of 29% Muriatic Acid
IC60 = 50%
10.0
FC
0.5
CC
7.7
pH
75
TA
3350
SALT
67 °F
TEMP
-0.16
CSI
7.4
pH
-0.38
CSI
48 oz of 29% Muriatic Acid
IC60 = 60%
9.0
FC
0.0
CC
7.8
pH
75
TA
3200
SALT
71 °F
TEMP
-0.04
CSI
7.4
pH
3450
SALT
-0.36
CSI
Cleaned IC60 Installed two new skimmer floats
40 lbs of Salt
32 oz of 29% Muriatic Acid
8.0
FC
0.0
CC
7.8
pH
75
TA
625
CH
110
CYA
3000
SALT
74 °F
TEMP
0.00
CSI
9.3
FC
0.4
CC
7.7
pH
43
TA
500
CH
118
CYA
3103
SALT
78 °F
TEMP
-1.29
CSI
Leslie’s Pool Supply test results 270 N El Camino Real
7.6
pH
-0.09
CSI
7.4
pH
-0.27
CSI
64 oz of 29% Muriatic Acid
5.5
FC
7.8
pH
75
TA
3150
SALT
77 °F
TEMP
0.09
CSI
7.4
pH
-0.27
CSI
IC60 = 70% Pool = 12PM-2PM, 12AM-4AM = 6h Cleaner = 12PM-2PM, 12AM-2AM = 4h
64 oz of 29% Muriatic Acid
5.0
FC
0.0
CC
8.0
pH
75
TA
600
CH
3150
SALT
78 °F
TEMP
0.28
CSI
IC60 = 60% Pool = 12PM-2PM, 12AM-4AM = 6h Cleaner = 12PM-2PM, 12AM-2AM = 4h
7.6
pH
-0.06
CSI
48 oz of 29% Muriatic Acid
7.0
FC
0.0
CC
7.8
pH
75
TA
3050
SALT
81 °F
TEMP
0.13
CSI
Cleaned Filter
Filter Pressure:14
32 oz of 29% Muriatic Acid
Reduce IC60 from 70% to 60% Pool = 12PM-2PM, 12AM-5AM = 7h Cleaner = 12PM-2PM, 1AM-3AM = 4h
7.5
FC
0.0
CC
7.8
pH
75
TA
3150
SALT
80 °F
TEMP
0.11
CSI
7.6
pH
-0.09
CSI
48 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
8.0
pH
75
TA
3050
SALT
78 °F
TEMP
0.28
CSI
Reduce IC60 from 75% to 70%
32 oz of 29% Muriatic Acid
7.2
FC
0.0
CC
7.8
pH
75
TA
600
CH
90
CYA
3150
SALT
79 °F
TEMP
0.11
CSI
Reduce IC60 from 80% to 75%
32 oz of 29% Muriatic Acid
6.5
FC
0.0
CC
7.8
pH
75
TA
625
CH
3050
SALT
81 °F
TEMP
0.11
CSI
7.6
pH
3000
SALT
84 °F
TEMP
-0.04
CSI
32 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.8
pH
75
TA
650
CH
3150
SALT
86 °F
TEMP
0.16
CSI
7.4
pH
80
TA
-0.19
CSI
64 oz of 29% Muriatic Acid
7.0
FC
0.0
CC
8.0
pH
88
TA
3050
SALT
83 °F
TEMP
0.43
CSI
21 oz of 29% Muriatic Acid
Reduce IC60 from 100% to 80%
7.8
FC
0.0
CC
7.8
pH
100
TA
625
CH
100
CYA
3150
SALT
82 °F
TEMP
0.31
CSI
SWG=100% Pool = 12PM-2PM, 12AM-6AM = 8h Cleaner = 12PM-2PM, 1AM-3AM = 4h
6.4
FC
7.6
pH
90
TA
-0.03
CSI
21 oz of 29% Muriatic Acid
7.8
pH
0.23
CSI
21 oz of 29% Muriatic Acid
6.0
FC
0.0
CC
7.8
pH
100
TA
3050
SALT
85 °F
TEMP
0.23
CSI
37 oz of 29% Muriatic Acid
40 lbs of Salt
6.0
FC
0.0
CC
8.0
pH
100
TA
500
CH
2950
SALT
85 °F
TEMP
0.42
CSI
6.0
FC
0.0
CC
8.0
pH
75
TA
650
CH
110
CYA
3000
SALT
80 °F
TEMP
0.25
CSI
5.5
FC
8.0
pH
2950
SALT
83 °F
TEMP
0.25
CSI
5.0
FC
7.8
pH
2900
SALT
84 °F
TEMP
0.07
CSI
SWG=100% Pool = 10AM-2PM, 12AM-6AM = 10h Cleaner = 11AM-1PM, 1AM-3AM = 4h
SWG = 100% Changed pool runtime 12h to 8h: Pool = 8AM-4PM, 1AM-5AM = 12h Cleaner = 10AM-2PM, 2AM-4AM = 6h To: Pool = 11AM-2PM, 12AM-5AM = 8h Cleaner = 12PM-1PM, 1AM-3AM = 3h
5.5
FC
7.8
pH
2950
SALT
87 °F
TEMP
0.10
CSI
6.2
FC
0.0
CC
7.8
pH
75
TA
600
CH
110
CYA
2950
SALT
85 °F
TEMP
0.08
CSI
5.8
FC
7.8
pH
75
TA
550
CH
2950
SALT
86 °F
TEMP
0.04
CSI
6.0
FC
7.8
pH
80
TA
550
CH
2950
SALT
85 °F
TEMP
0.09
CSI
5.5
FC
7.6
pH
115
CYA
2950
SALT
84 °F
TEMP
-0.07
CSI
8.0
FC
0.0
CC
7.6
pH
80
TA
600
CH
115
CYA
2950
SALT
84 °F
TEMP
-0.07
CSI
12.0
FC
0.0
CC
7.6
pH
80
TA
600
CH
115
CYA
3000
SALT
83 °F
TEMP
-0.07
CSI
14.0
FC
0.00
CSI
0.2
FC
0.2
CC
7.6
pH
60
TA
350
CH
115
CYA
3000
SALT
84 °F
TEMP
-0.58
CSI
Changed to SWG, added Pentair IC60. 10,000 hour life span / 8h / 365d = 3.4 years = 12/2024
Cleaned Filter
Filter Pressure:14