Pool

Volume: 12000 Gallons
Build Type: Vinyl
27 oz of Dry Stabilizer
40 lbs of Salt
10 lbs of Calcium Chloride
14.2
FC
1.0
CC
7.6
pH
66
TA
61
CH
43
CYA
2750
SALT
63 °F
TEMP
-1.17
CSI
Pool Opened Clear Replaced lights Replaced Filters Replaced Maytronics cleaner with Nautilus CC Supreme. Added shock. 1/4 gal muriatic acid SWG 35
2 gal LQ and some baking soda. Pool closed
Fall: SWG 35 7:15 - 5:00 Temp 60 deg
Orp 515 fc 4 pH 7.7
Orp 524 fc 6.5 ph 7.7
Orp 533 fc 6 ph 7.6
Orp 533 fc 4.5 CYA 60 target 4-9 min 3
Orp 543 fc 4 Raise swg 42
Orp 568 fc 10
10.0
FC
-0.32
CSI
Orp 553 fc 13 Lowered swg to 35
13.0
FC
0.0
CC
7.8
pH
70
TA
60
CYA
3300
SALT
40
BOR
-0.32
CSI
Pump schedule 7-11 2300 11-11 1400 SWG 7:15 - 7 50%
ORP 539 Fc 7.5
Orp 545 Fc 10
Orp 553 Fc 12 Reduced SWG 50
ORP 548 Fc 12 Reduced SWG to 60.
Orp 560= fc 10.5 ph 7.5
10.5
FC
-0.21
CSI
Adjust pump run time 8:00-11:00 Swg 68% 8:15 - 10:45 fc=4.1 Orp was dropping 545 to 535 from 8-11.
160 oz of Boric Acid
32 oz of Dry Stabilizer
Orp=539 Ph=7.8 Salt=3205 Temp 82.4
6.5
FC
0.5
CC
7.8
pH
70
TA
225
CH
40
CYA
3200
SALT
84 °F
TEMP
-0.21
CSI
ORP 548 fc 6 Ph 7.6
6.0
FC
-0.42
CSI
5.5
FC
-0.42
CSI
CSI- need to let Ph drift up to 7.8 and raise CH to 250. Lower SWG to 72
10.0
FC
0.0
CC
7.6
pH
70
TA
225
CH
60
CYA
3400
SALT
-0.42
CSI
40 lbs of Salt
6.0
FC
0.5
CC
7.6
pH
60
TA
50
CYA
2600
SALT
-0.53
CSI
4.0
FC
-0.58
CSI
Increase SWG 70 Cya=70 min 3 targ 5-10
16 oz of Dry Stabilizer
3.0
FC
0.5
CC
7.6
pH
60
TA
60
CYA
86 °F
TEMP
-0.58
CSI
Raise SWG to 60 / 2.7 fc Added CYA
2.5
FC
7.4
pH
50
CYA
-0.72
CSI
SWG=45 11 Hrs fc=2.1/day. Target 4-9.
7.5
FC
0.0
CC
7.2
pH
60
TA
187
CH
60
CYA
2919
SALT
20
BOR
86 °F
TEMP
-0.93
CSI
Added 2 pucks for CYA and exended SWG to 35 11 Hrs.
3.5
FC
0.5
CC
7.8
pH
60
TA
50
CYA
86 °F
TEMP
-0.34
CSI
6.5
FC
-0.55
CSI
Reduce SWG to 35 9 hours. Solar blank off.
14.0
FC
0.5
CC
7.6
pH
60
TA
86 °F
TEMP
-0.55
CSI
28 oz of Baking Soda
6.0
FC
7.4
pH
50
TA
-0.85
CSI
6.0
FC
-0.81
CSI
Added 2 pucks
3.0
FC
7.3
pH
60
TA
60
CYA
86 °F
TEMP
-0.81
CSI
5.5
FC
0.0
CC
7.3
pH
-0.84
CSI
8.0
FC
7.3
pH
-0.84
CSI
Swg=30 9 Hrs + 2 pucks to raise CYA Pump: 1 11:00 2400. 2 1400 10. 3 0 12. Solar blanket on. Added 1/2 Gal Muriatic 1 bag salt.
6.0
FC
0.5
CC
9.0
pH
80
TA
40
CYA
2800
SALT
60 °F
TEMP
0.41
CSI
Open pool Water temp 56.
9.0
FC
-0.61
CSI
6.5
FC
-0.61
CSI
Prepare to close. SWG @ 80% 24 Hr. Till 20 ppm.
3.0
FC
7.4
pH
70
TA
-0.61
CSI
3.0
FC
-0.61
CSI
SWG 30 11:15 - 8:15 Pump 0 12:00 11/ 1120 5 / 1120 4:30
3.0
FC
0.0
CC
7.4
pH
70
TA
50
CYA
-0.61
CSI
5.5
FC
-0.75
CSI
4.5
FC
-0.75
CSI
7.5
FC
-0.75
CSI
Reduce SWG 27% 11:15 - 8:15
7.0
FC
-0.75
CSI
6.0
FC
7.2
pH
-0.75
CSI
5.5
FC
-0.75
CSI
Freeze warming: heat pump to 78 Reduced SG to 30 Reduced pump to 1150 24/7 Old setting: SG 51 1- 2300 11:00 am 3:30 2- 1650 from 7:30 to 4 3- 2300 4:30 11:00am to 11:00 pm
8.0
FC
70
TA
-0.75
CSI
53 oz of Baking Soda
7.0
FC
0.0
CC
7.2
pH
40
TA
-1.05
CSI
8.0
FC
0.30
CSI
10.0
FC
0.30
CSI
lowered SWG from 61 to 51 Cold weather/blanket adjustment Added acid to lower PH
10.0
FC
0.0
CC
8.4
pH
70
TA
30
CYA
0.30
CSI
Changed SWG to 65 to raise FC to 4
60
CYA
3000
SALT
-0.47
CSI
3.5
FC
0.0
CC
7.5
pH
80
TA
40
CYA
-0.43
CSI
Added 2.4 lbs dry acid and 2.5 lbs cya
3.0
FC
0.0
CC
8.4
pH
70
TA
30
CYA
20
BOR
86 °F
TEMP
0.29
CSI
3.0
FC
-0.31
CSI
Changed pump run time to 12 hrs. Swg @ 60 = 3
3.5
FC
0.0
CC
7.8
pH
70
TA
-0.31
CSI
3.0
FC
0.0
CC
7.5
pH
70
TA
-0.57
CSI
4.0
FC
0.0
CC
7.4
pH
50
TA
60
CYA
-0.88
CSI
Lower SWG to 40
5.5
FC
0.0
CC
-0.11
CSI
Reduced SWG to 10 hours @ 45%=2 FC / day Add puck for CYA (2.5) FC= 1.5 per day CYA 50 = min 3 targ 4
3.0
FC
0.0
CC
8.0
pH
70
TA
50
CYA
3200
SALT
-0.11
CSI
sWg to 40
3.5
FC
0.0
CC
8.0
pH
70
TA
20
BOR
-0.21
CSI
SWG=35
4.0
FC
0.0
CC
7.8
pH
70
TA
80
CYA
-0.43
CSI
Added 1 puck of trichlor.
4.5
FC
0.0
CC
7.5
pH
65
TA
-0.65
CSI
3.5
FC
0.9
CC
7.3
pH
76
TA
197
CH
64
CYA
2857
SALT
-0.71
CSI
1 lbs of Dry Stabilizer
8.8
FC
0.0
CC
7.7
pH
104
TA
198
CH
23
CYA
2813
SALT
85 °F
TEMP
-0.10
CSI
Pool opened
Pool closer
10.0
FC
2.8
CC
7.5
pH
81
TA
203
CH
52
CYA
3400
SALT
-0.45
CSI
3.5 lbs of pH Down / Dry Acid
8.0
FC
0.15
CSI
11.0
FC
0.15
CSI
14.0
FC
0.0
CC
8.2
pH
90
TA
0.15
CSI
Remove cover, cut off SWG. Heater on with solar blanket
8.0
FC
-0.24
CSI
SWG 32 pool covered
5.0
FC
-0.24
CSI
8.0
FC
0.0
CC
7.7
pH
88
TA
208
CH
55
CYA
3600
SALT
-0.24
CSI
SWG 40 to add .5ppm 1.7ppm/day Pool covered with tarp
4.0
FC
-0.43
CSI
4.5
FC
-0.38
CSI
6.5
FC
0.5
CC
7.6
pH
80
TA
-0.38
CSI
Lower SWG 30 Covered pool with tarp.
5.5
FC
44
BOR
-0.43
CSI
25 lbs of Boric Acid
3.5
FC
0.0
CC
7.2
pH
70
TA
189
CH
3576
SALT
-0.83
CSI
41 oz of pH Down / Dry Acid
3.5
FC
0.0
CC
8.0
pH
90
TA
0.15
CSI
3.0
FC
0.5
CC
7.5
pH
-0.34
CSI
4.0
FC
7.5
pH
90
TA
-0.34
CSI
45 oz of pH Down / Dry Acid
4.0
FC
0.5
CC
8.4
pH
90
TA
59
CYA
3800
SALT
88 °F
TEMP
0.54
CSI
4.5
FC
-0.08
CSI
4.5
FC
7.8
pH
-0.08
CSI
5.5
FC
-0.08
CSI
5.5
FC
0.5
CC
7.8
pH
-0.08
CSI
5.0
FC
0.0
CC
7.5
pH
90
TA
3800
SALT
85 °F
TEMP
-0.37
CSI
Raise SWG to 35
5.5
FC
0.0
CC
7.2
pH
80
TA
4200
SALT
7.0
FC
6.0
CC
8.0
pH
7.5
FC
7.0
FC
SWG 6 hrs 40%
6.5
FC
0.5
CC
7.6
pH
7.0
FC
0.0
CC
7.5
pH
100
TA
CYA @ 60 FC min 3 targ 4 slam 24 Liquid 7-9 Borates 50
3 lbs of pH Down / Dry Acid
Vacuumed Brushed Cleaned Filter
10.6
FC
1.2
CC
7.9
pH
113
TA
232
CH
59
CYA
3119
SALT
0
BOR
8.5
FC
8.0
pH
120
TA
9.0
FC
0.5
CC
130
TA
45
CYA
10.0
FC
8.0
FC
7.3
pH
50
CYA
3 lbs of pH Down / Dry Acid
7.0
FC
0.1
CC
7.9
pH
144
TA
216
CH
40
CYA
3150
SALT
7.0
FC
0.0
CC
7.4
pH
130
TA
275
CH
45
CYA
4200
SALT
2 lbs of 73% Cal-Hypo
0.2
FC
0.2
CC
7.9
pH
152
TA
171
CH
5
CYA
0
SALT
0
BOR