Larsen Paradise

Volume: 16000 Gallons
Build Type: Plaster
$33.04 on Salt
Vacuumed
increased salt cell output from 75% to 80%
60 oz of 31.45% (20º Be) Muriatic Acid
3.5
FC
0.0
CC
8.0
pH
150
TA
240
CH
40
CYA
0.28
CSI
2 gal of 31.45% (20º Be) Muriatic Acid
intelliPH - Added 2 gallons of water and 2 gallons of 31.45% MA.
Brushed
Brushed
intelliPH - added 1 gal water and 1 gal 31.45% MA
1 gal of 31.45% (20º Be) Muriatic Acid
$39.99 on Muriatic acid
16 lbs of Calcium Chloride
64 oz of Dry Stabilizer
$44.86 on Calcium increaser
$31.98 on Dry Stabilizer
5.0
FC
0.0
CC
8.0
pH
140
CH
70 °F
TEMP
-0.15
CSI
Brushed
120 lbs of Salt
$23.78 on Salt
Vacuumed
Increased pump runtime from 8am to 9pm to 7am to 7pm. SWG still set at 75%
10 lbs of Calcium Chloride
32 oz of Dry Stabilizer
IntelliPH added 1 gal water and 1 gat 31.45% MA
1 gal of 31.45% (20º Be) Muriatic Acid
2.5
FC
0.0
CC
8.0
pH
90
TA
160
CH
10
CYA
55 °F
TEMP
-0.24
CSI
Brushed
80 lbs of Salt
$17.96 on Salt
40 lbs of Salt
Brushed
5.0
FC
0.0
CC
8.0
pH
-0.09
CSI
Brushed
7.0
FC
0.0
CC
8.0
pH
80
TA
4300
SALT
56 °F
TEMP
-0.09
CSI
IntelliPH - added 1 gal of water and 1 gal of MA. was empty.
1 gal of 31.45% (20º Be) Muriatic Acid
$19.48 on Muriatic acid
$8.98 on Salt
80 lbs of Salt
Brushed
FC is high I reduced the pump runtime from 7am to 10Pm to 8am to 6pm. cell is at 75% still
13.0
FC
0.0
CC
7.6
pH
270
CH
30
CYA
2800
SALT
61 °F
TEMP
-0.32
CSI
Brushed
Brushed
1 gal of 31.45% (20º Be) Muriatic Acid
intelliPH - Added 1 gal or water and 1 gal of 31.45% MA
240 oz of Calcium Chloride
32 oz of Dry Stabilizer
8.0
FC
0.0
CC
7.6
pH
-0.43
CSI
intelliPH decreased output from 48% to 40%
80 lbs of Salt
11.5
FC
0.0
CC
7.6
pH
210
CH
30
CYA
2900
SALT
62 °F
TEMP
-0.43
CSI
$19.48 on Muriatic acid
128 oz of Calcium Chloride
32 oz of Dry Stabilizer
6.0
FC
0.0
CC
7.8
pH
90
TA
190
CH
20
CYA
3000
SALT
66 °F
TEMP
-0.23
CSI
Brushed
1 gal of 31.45% (20º Be) Muriatic Acid
intelliPH - added 1 gal of 31.46% MA and 1 gal of water
120 lbs of Salt
4.5
FC
0.0
CC
8.0
pH
90
TA
210
CH
30
CYA
2400
SALT
82 °F
TEMP
0.17
CSI
$39.96 on Muriatic acid
$20.00 on Salt
Vacuumed
Brushed
intelliPH - added 1gal of 31.45% MA and 1 gal water.
1 gal of 31.45% (20º Be) Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
100
TA
0.12
CSI
4.0
FC
0.0
CC
7.8
pH
100
TA
35
CYA
0.12
CSI
intellipH - added 1 gal of 31.45% MA and 1 gal of water
1 gal of 31.45% (20º Be) Muriatic Acid
intelliPH - increased by 5% to 48%.
52 oz of 31.45% (20º Be) Muriatic Acid
5.0
FC
0.0
CC
8.0
pH
0.34
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
intelliPH - added 1 gal or 31.45% MA and 1 gal of water
120 lbs of Salt
intelliPH - added 1 gal of 31.45% MA and 1 gal of water
1 gal of 31.45% (20º Be) Muriatic Acid
$23.52 on Salt
$39.96 on Muriatic acid
32 oz of 31.45% (20º Be) Muriatic Acid
64 oz of Dry Stabilizer
3.5
FC
0.0
CC
8.0
pH
20
CYA
2800
SALT
0.34
CSI
Brushed
4.5
FC
0.0
CC
7.8
pH
100
TA
250
CH
87 °F
TEMP
0.08
CSI
33 oz of 31.45% (20º Be) Muriatic Acid
2.5
FC
8.0
pH
0.26
CSI
3.5
FC
7.6
pH
-0.13
CSI
16 oz of Liquid Chlorine • 10%
20 gal of 31.45% (20º Be) Muriatic Acid
2.5
FC
0.0
CC
7.8
pH
45
CYA
0.06
CSI
11 oz of 34.6% (22º Be) Muriatic Acid
2 lbs of Dry Stabilizer
2.0
FC
0.0
CC
7.8
pH
100
TA
30
CYA
3200
SALT
87 °F
TEMP
0.09
CSI
intelliPH added 1 gal of water and 1 gal of 31.45% MA
1 gal of 31.45% (20º Be) Muriatic Acid
intellipH - increased from 37 to 40%
7.8
pH
0.04
CSI
Brushed
intellipH - added 1 gal of 31.45% MA and 1gal of water.
1 gal of 31.45% (20º Be) Muriatic Acid
16 oz of 31.45% (20º Be) Muriatic Acid
4.5
FC
0.0
CC
8.0
pH
87 °F
TEMP
0.24
CSI
8.0
FC
0.0
CC
8.0
pH
240
CH
40
CYA
3900
SALT
83 °F
TEMP
0.21
CSI
60 oz of 34.6% (22º Be) Muriatic Acid
Brushed
Cleaned Filter
4 lbs of Dry Stabilizer
$54.10 on Dry Stabilizer
16 lbs of Calcium Chloride
2.5
FC
0.0
CC
8.0
pH
100
TA
150
CH
0
CYA
0.11
CSI
160 lbs of Salt
2550
SALT
-0.25
CSI
3.0
FC
0.0
CC
7.8
pH
90
TA
80 °F
TEMP
-0.31
CSI
intelliPh - added 1 gal of 31.45% MA and 1 gal of water.
1 gal of 31.45% (20º Be) Muriatic Acid
Brushed
intellipH added 1 gal of water and 1 gal of 31.45% MA.
1 gal of 31.45% (20º Be) Muriatic Acid
$19.98 on Muriatic acid
5.5
FC
0.0
CC
7.8
pH
110
TA
74 °F
TEMP
-0.27
CSI
Vacuumed
44 oz of 31.45% (20º Be) Muriatic Acid
$37.74 on Calcium increaser
60 oz of Dry Stabilizer
4 lbs of Calcium Chloride
3.5
FC
0.0
CC
8.0
pH
120
TA
130
CH
30
CYA
-0.06
CSI
Brushed
1 gal of 31.45% (20º Be) Muriatic Acid
IntelliPh - Added 1 gal of 31.45% MA and 1gal of water
$17.45 on Muriatic acid
4.5
FC
0.0
CC
7.8
pH
120
TA
3800
SALT
71 °F
TEMP
-0.07
CSI
Vacuumed
160 lbs of Salt
64 oz of 31.45% (20º Be) Muriatic Acid
Brushed
$31.36 on Salt
4.0
FC
0.0
CC
8.0
pH
30
CYA
2600
SALT
67 °F
TEMP
0.15
CSI
32 oz of 31.45% (20º Be) Muriatic Acid
74 oz of Liquid Chlorine • 10%
80 lbs of Salt
$18.96 on Salt
$7.78 on Liquid Chlorine / Bleach • 10%
$18.98 on Muriatic acid
0.5
FC
8.0
pH
0.15
CSI
6.0
FC
0.0
CC
7.8
pH
120
TA
67 °F
TEMP
-0.04
CSI
intellipH, increased from 25% to 30%
10.0
FC
0.0
CC
8.0
pH
130
TA
200
CH
35
CYA
53 °F
TEMP
0.06
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
intellipH - Added 1 gal of 31.45% MA and 1 gal of water to intellipH.
Vacuumed
Brushed
intellipH - increased % from 19 to 25%
11.0
FC
0.0
CC
8.0
pH
140
TA
50 °F
TEMP
0.05
CSI
Turned Salt Cell back on to 60% but changed pump schedule to run at 1,100RPM from 8am to midnight instead of 24x7
128 oz of Liquid Chlorine • 10%
4 lbs of Calcium Chloride
120 lbs of Salt
adding salt so turned Salt Cell off. was at 34%
$11.82 on Calcium increaser
$23.52 on Salt
1.5
FC
8.0
pH
130
TA
200
CH
50
CYA
2400
SALT
60 °F
TEMP
0.10
CSI
14.0
FC
0.0
CC
8.0
pH
120
TA
59 °F
TEMP
0.10
CSI
17.0
FC
0.0
CC
8.0
pH
100
TA
49 °F
TEMP
-0.10
CSI
4 lbs of Calcium Chloride
120 lbs of Salt
Turned Salt Cell off because I'm adding salt. was at 34%
$26.34 on Salt
$12.56 on Calcium increaser
Brushed
6.0
FC
0.5
CC
7.8
pH
100
TA
220
CH
55
CYA
2400
SALT
62 °F
TEMP
-0.18
CSI
7.5
FC
7.8
pH
100
TA
55 °F
TEMP
-0.19
CSI
128 oz of Liquid Chlorine • 10%
Added 6 3in chlorine tablets
intellipH - increased MA output from 17% to 19%
11.0
FC
8.0
pH
100
TA
-0.02
CSI
208 oz of Liquid Chlorine • 10%
4.5
FC
7.8
pH
100
TA
-0.21
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
IntellipH - added 1 gal water and 1 gal 31.45%MA. Was about 1.5gal left now about 2.5gal
Vacuumed
39 oz of Baking Soda
17 oz of Borax (20 Mule)
5.0
FC
0.0
CC
7.6
pH
80
TA
53 °F
TEMP
-0.53
CSI
$69.99 on Trichlor tablets/pucks
$14.98 on Calcium increaser
$16.48 on Muriatic acid
intellipH - decreased from 20% to 17%. pH still decreases
intelliChlor - Increased from 32% to 34%
51 oz of Liquid Chlorine • 10%
2.5
FC
7.4
pH
80
TA
280
CH
60
CYA
3200
SALT
70 °F
TEMP
-0.55
CSI
Brushed
intellipH - turned back on to 20%
64 oz of Dry Stabilizer
3.0
FC
0.0
CC
7.6
pH
80
TA
30
CYA
72 °F
TEMP
-0.26
CSI
128 oz of 31.45% (20º Be) Muriatic Acid
intellipH - Added 1gal of 31.45% MA ans 1gal water. Tank is now at 3 gal mark
intellipH - turned back on to 26%
intellipH - turned off to try and get pH increased to 7.8 or so and then will turn back on to 26% instead of 30%
4 lbs of Baking Soda
5.0
FC
0.0
CC
7.4
pH
70
TA
68 °F
TEMP
-0.61
CSI
Vacuumed
$36.15 on Dry Stabilizer
5.5
FC
7.6
pH
55
CYA
69 °F
TEMP
-0.34
CSI
6.0
FC
0.0
CC
7.6
pH
80
TA
-0.27
CSI
6.0
FC
0.0
CC
7.8
pH
80
TA
70 °F
TEMP
-0.08
CSI
4 lbs of Dry Stabilizer
4.5
FC
0.0
CC
7.8
pH
30
CYA
-0.13
CSI
Brushed
intellipH - Turned back on to 30%
5.5
FC
8.0
pH
70
TA
-0.02
CSI
intellipH - turned off to get pH up some.
4.0
FC
7.6
pH
70
TA
300
CH
73 °F
TEMP
-0.40
CSI
128 oz of 31.45% (20º Be) Muriatic Acid
intellipH added 1 gal water and 1 gal 31.45% MA. tank was just below 1 gal left now at 3.
$16.48 on Muriatic acid
Vacuumed
Increased salt cell from 28% to 32%
3.0
FC
0.0
CC
7.6
pH
70
TA
-0.43
CSI
5.0
FC
7.6
pH
70
TA
-0.43
CSI
4 lbs of Calcium Chloride
Decreased salt cell from 30% to 28%
7.5
FC
7.6
pH
80
TA
3400
SALT
76 °F
TEMP
-0.35
CSI
$9.97 on Calcium increaser
8.0
FC
0.0
CC
7.6
pH
70
TA
260
CH
79 °F
TEMP
-0.40
CSI
Brushed
75 oz of Baking Soda
8.0
FC
0.0
CC
7.4
pH
50
TA
-0.77
CSI
IntellipH decreased from 32% to 31%.
10.0
FC
7.4
pH
50
TA
84 °F
TEMP
-0.77
CSI
intellipH added 1 gal water and 1 gal 31.45% MA. tank was just below 1 gal left now at 3.
128 oz of 31.45% (20º Be) Muriatic Acid
Vacuumed
IntellipH decreased from 33% to 32%.
Decreased salt cell from 40% to 30%
12.0
FC
7.4
pH
84 °F
TEMP
-0.65
CSI
Brushed
Decreased salt cell from 50% to 40%
13.0
FC
0.0
CC
7.4
pH
-0.66
CSI
12.0
FC
7.6
pH
60
TA
-0.48
CSI
12.5
FC
-0.19
CSI
Vacuumed
Brushed
12.5
FC
7.8
pH
-0.19
CSI
IntellipH increased from 31% to 33%. pH last night was closer to 8 than 7.8 so adding a bit more acid to decrease pH.
Decreased salt cell from 60% to 50%
12.0
FC
0.0
CC
7.8
pH
-0.19
CSI
11.0
FC
7.8
pH
-0.19
CSI
12.0
FC
-0.38
CSI
Decreased salt cell from 70% to 60%
12.5
FC
0.0
CC
260
CH
-0.38
CSI
13.0
FC
81 °F
TEMP
-0.31
CSI
14.0
FC
0.0
CC
7.6
pH
70
TA
-0.29
CSI
Vacuumed
15.5
FC
7.6
pH
-0.29
CSI
Brushed
Decreased salt cell from 80% to 70%
18.5
FC
-0.29
CSI
19.5
FC
-0.29
CSI
intellipH added 1 gallon of water and 1 gallon of 31.45% MA. Tank was just below 1 gal left.
128 oz of 31.45% (20º Be) Muriatic Acid
Decreased salt cell from 90% to 80%
22.0
FC
0.0
CC
7.6
pH
70
TA
3400
SALT
83 °F
TEMP
-0.29
CSI
$16.48 on Muriatic acid
20.0
FC
-0.31
CSI
20.5
FC
-0.31
CSI
Decreased salt cell from 100% to 90%
22.0
FC
7.6
pH
-0.31
CSI
26.5
FC
-0.12
CSI
28.5
FC
-0.12
CSI
35.0
FC
0.0
CC
-0.12
CSI
36.5
FC
-0.12
CSI
72 oz of Liquid Chlorine • 10%
31.5
FC
-0.12
CSI
148 oz of Liquid Chlorine • 10%
28.0
FC
-0.12
CSI
Brushed
61 oz of Liquid Chlorine • 10%
32.0
FC
-0.12
CSI
Bringing pool up to yellow algae slam level (FC 35ppm) for 24 hours just to ensure everything is gone. pool is crystal clear and no algae in sight but after I lowered FC levels after both previous slams things went wonky again.
215 oz of Liquid Chlorine • 10%
24.5
FC
-0.12
CSI
24.5
FC
7.8
pH
81 °F
TEMP
-0.12
CSI
24.5
FC
-0.46
CSI
$9.94 on Liquid Chlorine / Bleach • 10%
24.5
FC
-0.46
CSI
20 oz of Liquid Chlorine • 10%
23.0
FC
-0.46
CSI
64 oz of Liquid Chlorine • 10%
21.0
FC
60
CYA
-0.46
CSI
24.5
FC
-0.46
CSI
21.0
FC
-0.46
CSI
22.5
FC
-0.46
CSI
128 oz of Liquid Chlorine • 10%
18.0
FC
60
CYA
-0.46
CSI
$29.82 on Liquid Chlorine / Bleach • 10%
17.5
FC
-0.46
CSI
Vacuumed
256 oz of Liquid Chlorine • 10%
13.5
FC
-0.46
CSI
OCLT is a bad test today. We got a bunch of rain this morning.
16.0
FC
-0.46
CSI
Performing OCLT
256 oz of Liquid Chlorine • 10%
7.4
FC
-0.49
CSI
$19.88 on Liquid Chlorine / Bleach • 10%
7.4
FC
60
CYA
-0.46
CSI
Brushed
Vacuumed
Turned Salt Cell on and to 100%
128 oz of Liquid Chlorine • 10%
OCLT passed but barely.
1.6
FC
-0.49
CSI
2.6
FC
-0.49
CSI
performing OCLT again. Seems like the salt cell should keep up at 45% and I shouldn't be loosing that much chlorine.
4.0
FC
0.0
CC
-0.49
CSI
IntellipH decreased from 34% to 31%
increase salt cell from 38% to 45%
4.0
FC
7.4
pH
-0.49
CSI
increase salt cell from 30% to 38%
4.5
FC
85 °F
TEMP
-0.46
CSI
Increasing salt cell from 20% to 30%.
5.5
FC
0.0
CC
7.4
pH
70
TA
70
CYA
-0.46
CSI
increased salt cell to 20% again
8.0
FC
-0.40
CSI
decreasing salt cell to 5% over night and will bump it back to 20% tomorrow sometime. Trying to get FC down
12.5
FC
-0.40
CSI
Salt Cell reduced from 30% to 20%. Trying to get FC to drop a bit quicker.
13.0
FC
0.0
CC
7.4
pH
80
TA
-0.40
CSI
Brushed
Salt Cell reduced from 40% to 30%
14.0
FC
0.0
CC
7.2
pH
80
TA
-0.58
CSI
128 oz of 31.45% (20º Be) Muriatic Acid
intellipH added 1 gal of water and 1 gal of 31.45% muriatic acid. Tank was at 1gal left and now at 3
32 oz of 31.45% (20º Be) Muriatic Acid
12 oz of Dry Stabilizer
Salt Cell reduced from 50% to 40%
13.0
FC
0.0
CC
7.6
pH
90
TA
65
CYA
-0.14
CSI
32 oz of 31.45% (20º Be) Muriatic Acid
Salt Cell reduced from 60% to 50%
11.0
FC
7.6
pH
100
TA
-0.06
CSI
Salt Cell reduced from 70% to 60%
10.5
FC
0.08
CSI
43 oz of Dry Stabilizer
passed OCLT
11.0
FC
0.08
CSI
11.0
FC
0.08
CSI
Starting OCLT before adding Stabilizer
10.0
FC
0.08
CSI
10.8
FC
0.2
CC
7.8
pH
90
TA
50
CYA
0.08
CSI
14.0
FC
-0.10
CSI
14.4
FC
85 °F
TEMP
-0.10
CSI
Vacuumed
Brushed
128 oz of Liquid Chlorine • 10%
Cleaned Filter
14.8
FC
-0.10
CSI
15.8
FC
-0.10
CSI
15.5
FC
-0.10
CSI
$20.94 on Dry Stabilizer
$9.94 on Liquid Chlorine / Bleach • 10%
14.2 oz of Dry Stabilizer
18.4
FC
-0.10
CSI
16.0
FC
-0.10
CSI
15.5
FC
7.6
pH
45
CYA
-0.10
CSI
38 oz of Liquid Chlorine • 10%
Completed OCLT and lost .6 FC - Pass
19.0
FC
0.08
CSI
19.6
FC
0.08
CSI
20.0
FC
0.08
CSI
94 oz of Liquid Chlorine • 10%
15.4
FC
0.08
CSI
64 oz of Liquid Chlorine • 10%
17.0
FC
7.8
pH
90
TA
3400
SALT
0.08
CSI
62 oz of Liquid Chlorine • 10%
17.0
FC
-0.43
CSI
16.4
FC
-0.43
CSI
18.5
FC
-0.43
CSI
32 oz of Liquid Chlorine • 10%
21.0
FC
-0.43
CSI
21.0
FC
-0.43
CSI
32 oz of Liquid Chlorine • 10%
18.5
FC
-0.43
CSI
42 oz of Liquid Chlorine • 10%
18.0
FC
-0.43
CSI
21.5
FC
-0.43
CSI
21.5
FC
-0.43
CSI
Brushed
51 oz of Liquid Chlorine • 10%
17.5
FC
-0.43
CSI
$14.91 on Liquid Chlorine / Bleach • 10%
32 oz of Liquid Chlorine • 10%
18.5
FC
-0.43
CSI
23.5
FC
-0.43
CSI
21.0
FC
-0.43
CSI
61 oz of Liquid Chlorine • 10%
17.0
FC
50
CYA
-0.43
CSI
61 oz of Liquid Chlorine • 10%
21.0
FC
-0.45
CSI
31 oz of Liquid Chlorine • 10%
22.5
FC
-0.45
CSI
24.0
FC
-0.45
CSI
Vacuumed
intellipH added 1 gallon of water and 1 gallon of muriatic acid. had about 1 gallon in the tank and filled to about 3
1 gal of 31.45% (20º Be) Muriatic Acid
Brushed
164 oz of Liquid Chlorine • 10%
16.0
FC
-0.45
CSI
$16.48 on Muriatic acid
25.5
FC
-0.45
CSI
128 oz of Liquid Chlorine • 10%
21.0
FC
-0.45
CSI
61 oz of Liquid Chlorine • 10%
21.0
FC
-0.45
CSI
143 oz of Liquid Chlorine • 10%
17.0
FC
-0.45
CSI
64 oz of Liquid Chlorine • 10%
92 oz of Liquid Chlorine • 10%
20.0
FC
-0.45
CSI
72 oz of Liquid Chlorine • 10%
20.5
FC
-0.45
CSI
128 oz of Liquid Chlorine • 10%
21.0
FC
-0.45
CSI
22.5
FC
-0.45
CSI
$39.76 on Liquid Chlorine / Bleach • 10%
128 oz of Liquid Chlorine • 10%
128 oz of Liquid Chlorine • 10%
18.0
FC
-0.45
CSI
128 oz of Liquid Chlorine • 10%
174 oz of Liquid Chlorine • 10%
15.5
FC
-0.45
CSI
40 lbs of Salt
440 oz of Liquid Chlorine • 10%
Salt cell turned off. Adding salt
2.5
FC
-0.45
CSI
$6.97 on Salt
$29.82 on Liquid Chlorine / Bleach • 10%
2.8
FC
-0.45
CSI
Turned cell off. Started an Overnight FC Loss Test. Feels like something is consuming FC
4.2
FC
-0.45
CSI
Salt cell output increased for 60% to 70%
IntellipH decreased from 35% to 34%
Checked and pushed just a little calcium out of salt cell with a Popsicle stick
165 oz of Liquid Chlorine • 10%
0.6
FC
0.2
CC
7.4
pH
70
TA
60
CYA
85 °F
TEMP
-0.45
CSI
Increasing salt output from 50% to 60%
2.2
FC
-0.45
CSI
changing salt cell from 45% to 50%
2.0
FC
0.2
CC
7.4
pH
70
TA
65
CYA
3200
SALT
86 °F
TEMP
-0.45
CSI
Brushed
Flow Rate:29
4.5
FC
7.4
pH
80
TA
65
CYA
85 °F
TEMP
-0.39
CSI
32 oz of Dry Stabilizer
changing salt cell to 45% from 50%
6.5
FC
7.4
pH
80
TA
85 °F
TEMP
-0.37
CSI
57 oz of 31.45% (20º Be) Muriatic Acid
Cleaned Filter
Filter Pressure:12
Flow Rate:92
6.6
FC
0.2
CC
7.6
pH
100
TA
86 °F
TEMP
-0.05
CSI
1 gal of 31.45% (20º Be) Muriatic Acid
IntellipH - added 1 gallon of water and 1 gallon of 31.45% MA. Now at 3 gallons in tank
Reducing salt cell from 60 to 50%
8.6
FC
7.6
pH
100
TA
-0.03
CSI
running bubblers to bump up pH and so I can add muriatic acid to get TA down
9.5
FC
7.4
pH
-0.18
CSI
8.8
FC
0.2
CC
7.4
pH
110
TA
310
CH
50
CYA
88 °F
TEMP
-0.18
CSI
4 lbs of Dry Stabilizer
salt cell turned on and set to 60%
OCLT passed
10.8
FC
0.2
CC
7.6
pH
30
CYA
-0.05
CSI
11.6
FC
0.2
CC
-0.05
CSI
Start of Overnight chlorine loss test
9.8
FC
-0.05
CSI
50 oz of Liquid Chlorine • 10%
9.6
FC
-0.05
CSI
29 oz of Liquid Chlorine • 10%
10.6
FC
0.2
CC
-0.05
CSI
Vacuumed
20 oz of Liquid Chlorine • 10%
11.4
FC
-0.05
CSI
12 oz of Liquid Chlorine • 10%
11.8
FC
0.2
CC
-0.05
CSI
Brushed
20 oz of Liquid Chlorine • 10%
11.2
FC
7.6
pH
30
CYA
-0.05
CSI
46 oz of Liquid Chlorine • 10%
9.8
FC
0.16
CSI
48 oz of Liquid Chlorine • 10%
9.8
FC
0.16
CSI
1 lbs of Dry Stabilizer
128 oz of Liquid Chlorine • 10%
6.8
FC
25
CYA
0.00
CSI
$16.48 on Muriatic acid
$27.78 on Liquid Chlorine / Bleach • 10%
68 oz of Liquid Chlorine • 10%
9.0
FC
0.00
CSI
165 oz of Liquid Chlorine • 10%
Starting a SLAM because of the over night chlorine loss. Goal is to get CYA to 30 which it was close this morning after adding the just over 1 lb of CYA because I could barely see the dot when the test vial was full of mix. I had dissolved most of the CYA added this morning in a bucket by leaving it in the bucket all night and then squeezing it till the granules were mostly mixed into the water. Salt cell changed to 100%
1 lbs of Dry Stabilizer
3.6
FC
0.00
CSI